TROUBLESHOOTING | ||
|
|
|
| Observe all Safety Guidelines detailed throughout this manual |
|
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
ARCLINK SYSTEM ERROR CODES
Err 44 Main CPU problem. | 1. Verify the earth ground connec- |
| ||
|
| tion to the power source is wired |
| |
|
| correctly. |
| |
| 2. See the power source Instruction |
| ||
|
| Manual. |
| |
|
|
| ||
Err 53 Voltage sense loss. | 1. Verify correct sense lead connection. |
| ||
|
|
|
|
|
Err 54 Short term secondary over- |
|
|
|
|
current. |
|
|
|
|
|
|
| ||
Err 81 Motor overload, long term. | 1. The wire drive motor has over- |
| ||
|
| heated. Check that the electrode |
| |
|
| slides easily through the gun and |
| |
|
| cable. |
| |
| 2. | Remove tight bends from the gun |
| |
|
| and cable. |
| |
| 3. | Check that the spindle brake is |
| |
|
| not too tight. |
| |
| 4. | Verify a high quality electrode is |
| |
|
| being used. | If all recommended possible areas | |
| 5. | Wait for the error to reset and the | ||
|
| motor to cool (approximately 1 | of misadjustment have been | |
|
| minute). | checked and the problem persists, | |
|
| Contact your local Lincoln | ||
| 6. | Long term average motor current | ||
|
| limit | has been exceeded. | Authorized Field Service Facility. |
|
| Typically indicates mechanical |
| |
|
| overload of system. If problem |
| |
|
| continues consider higher torque |
| |
|
| gear ratio (lower speed range). |
| |
|
|
| ||
Err 82 Motor overload, short term. | 1. The wire drive motor current draw |
| ||
|
| has | exceeded limits, usually |
|
|
| because the motor is in a locked |
| |
|
| rotor state. Check that motor can |
| |
|
| turn freely when idle arm is open. |
| |
| 2. Verify that the gears are free of |
| ||
|
| debris and dirt. |
| |
|
|
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.