Lincoln Electric IM10023 manual Verify correct sense lead connection

Page 40

E-5

TROUBLESHOOTING

E-5

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

ARCLINK SYSTEM ERROR CODES

Err 44 Main CPU problem.

1. Verify the earth ground connec-

 

 

 

tion to the power source is wired

 

 

 

correctly.

 

 

2. See the power source Instruction

 

 

 

Manual.

 

 

 

 

Err 53 Voltage sense loss.

1. Verify correct sense lead connection.

 

 

 

 

 

 

Err 54 Short term secondary over-

 

 

 

 

current.

 

 

 

 

 

 

 

Err 81 Motor overload, long term.

1. The wire drive motor has over-

 

 

 

heated. Check that the electrode

 

 

 

slides easily through the gun and

 

 

 

cable.

 

 

2.

Remove tight bends from the gun

 

 

 

and cable.

 

 

3.

Check that the spindle brake is

 

 

 

not too tight.

 

 

4.

Verify a high quality electrode is

 

 

 

being used.

If all recommended possible areas

 

5.

Wait for the error to reset and the

 

 

motor to cool (approximately 1

of misadjustment have been

 

 

minute).

checked and the problem persists,

 

 

Contact your local Lincoln

 

6.

Long term average motor current

 

 

limit

has been exceeded.

Authorized Field Service Facility.

 

 

Typically indicates mechanical

 

 

 

overload of system. If problem

 

 

 

continues consider higher torque

 

 

 

gear ratio (lower speed range).

 

 

 

 

Err 82 Motor overload, short term.

1. The wire drive motor current draw

 

 

 

has

exceeded limits, usually

 

 

 

because the motor is in a locked

 

 

 

rotor state. Check that motor can

 

 

 

turn freely when idle arm is open.

 

 

2. Verify that the gears are free of

 

 

 

debris and dirt.

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

MAXsa™ 10 CONTROLLER

Image 40
Contents Controller Safety Electric Shock can kill Welding and Cutting Sparks can Cause fire or explosion Précautions DE Sûreté Thank You Table of Contents Installation Technical Specifications MAXsa 10 ControllerSafety Precaution Figure A.1 MAXsa 10 Connections Interfacing to the MAXsa 10 CON TrollerFigure A.3 Figure A.4 Controlling NON-LINCOLN Equipment Shutdown Inputs Stop InputFigure A.6 Connection Diagram Single ARC System Safety Precautions Design FeaturesOperation Definitions of Welding ModesRecommended Processes and Equipment General Physical DescriptionGeneral Functional Description Common Basic Equipment Packages200 Wire Feeder Setup POWER-UP SequenceSetting Feed FORWARD/REVERSE Changing and Setting Weld Modes Frequency AdjustBalance Adjust Offset AdjustWeld Mode Searching Searching for a Weld ModeMultiple ARC Configuration Table B.1 Phase Relationship ARCArc Delay Time Weld SequenceStart Options Operation Start OptionsEND Options Operation END OptionsDownslope Time Accessing the Setup Menu Access Preference ChangeParameter Definition Preference SelectionUser Defined Parameters Wire Drive Gear Ratio 100 View Diagnostics?Parameter Definition Hot-Inch Touch Sense Option Shutdown 2 Function Select107 View Power Source Protocol Parameter Definition 101 View Event Logs102 View Fatal Logs 103 View Software Version Information503 Memory Button Disable 504 Mode Select Panel Lock505 Setup Menu Lock Parameter Definition 502 Memory Change LockoutParameter Definition 506 Set User Interface Passcode 509 UI Master LockoutTouch Sense Lockout / SecurityMaking a Weld Figure B.7 Making a WeldNaming a Saved Procedure Using the Memory OptionMulti Procedure Welding Saving a Procedure to a Memory Location Recalling a Procedure from a Memory LocationSteel 1/8 CC DC +Optional Limit Setup Setting LimitsAccessories Follow these stepsRoutine Maintenance MaintenancePeriodic Maintenance Calibration Specification Troubleshooting HOW to USE Troubleshooting GuideUsing the Status LED to Troubleshoot System Problems Table E.1Arclink System Error Codes Troubleshooting Verify correct sense lead connection Output Disabled Output Problems Troubleshooting Diagrams Enhanced DiagramDimension Print L13444Precaucion Warnung