TROUBLESHOOTING | ||
|
|
|
| Observe all Safety Guidelines detailed throughout this manual |
|
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
| ARCLINK SYSTEM ERROR CODES |
|
| ||
Err 31 | Primary overcurrent | 1. | The power source has exceeded |
| |
|
|
| input current limits. Adjust the |
| |
|
|
| welding procedure to reduce the |
| |
|
|
| current draw. The welding proce- |
| |
|
|
| dure may exceed the capacity of |
| |
|
|
| the power source. |
|
|
|
| 2. | See the power source Instruction |
| |
|
|
| Manual. |
|
|
|
|
|
|
| |
Err 32 | Capacitor bank "A" under | 1. | The power source input power |
| |
| voltage. |
| may be wired incorrectly. Verify |
| |
|
|
| the power source | reconnect |
|
|
|
| panel wiring matches the input |
| |
|
|
| power. |
| If all recommended possible areas of |
|
|
|
|
| |
|
| 2. | See the power source Instruction | misadjustment have been checked | |
|
|
| Manual. |
| and the problem persists, Contact |
|
|
|
|
| your local Lincoln Authorized Field |
Err 33 | Capacitor bank "B" under | 1. The power source input power | Service Facility. | ||
| voltage. | may be wired incorrectly. Verify |
| ||
|
| the power source reconnect panel |
| ||
|
| wiring matches the input power. |
| ||
|
| 2. | See the power source Instruction |
| |
|
|
| Manual. |
|
|
|
|
|
|
| |
|
| 1. | The power source input power |
| |
Err 34 | Capacitor bank "A" overvolt- |
| may be wired incorrectly. Verify |
| |
| age. |
| the power source | reconnect |
|
|
|
| panel wiring matches the input |
| |
|
|
| power. |
|
|
|
| 2. | See the power source Instruction |
| |
|
|
| Manual. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
MAXsa™ 10 CONTROLLER