E-3

TROUBLESHOOTING

E-3

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

 

ARCLINK SYSTEM ERROR CODES

 

 

Err 31

Primary overcurrent

1.

The power source has exceeded

 

 

 

 

input current limits. Adjust the

 

 

 

 

welding procedure to reduce the

 

 

 

 

current draw. The welding proce-

 

 

 

 

dure may exceed the capacity of

 

 

 

 

the power source.

 

 

 

 

2.

See the power source Instruction

 

 

 

 

Manual.

 

 

 

 

 

 

 

Err 32

Capacitor bank "A" under

1.

The power source input power

 

 

voltage.

 

may be wired incorrectly. Verify

 

 

 

 

the power source

reconnect

 

 

 

 

panel wiring matches the input

 

 

 

 

power.

 

If all recommended possible areas of

 

 

 

 

 

 

 

2.

See the power source Instruction

misadjustment have been checked

 

 

 

Manual.

 

and the problem persists, Contact

 

 

 

 

 

your local Lincoln Authorized Field

Err 33

Capacitor bank "B" under

1. The power source input power

Service Facility.

 

voltage.

may be wired incorrectly. Verify

 

 

 

the power source reconnect panel

 

 

 

wiring matches the input power.

 

 

 

2.

See the power source Instruction

 

 

 

 

Manual.

 

 

 

 

 

 

 

 

 

1.

The power source input power

 

Err 34

Capacitor bank "A" overvolt-

 

may be wired incorrectly. Verify

 

 

age.

 

the power source

reconnect

 

 

 

 

panel wiring matches the input

 

 

 

 

power.

 

 

 

 

2.

See the power source Instruction

 

 

 

 

Manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

MAXsa™ 10 CONTROLLER

Image 38
Contents Controller Safety Electric Shock can kill Welding and Cutting Sparks can Cause fire or explosion Précautions DE Sûreté Thank You Table of Contents Installation Technical Specifications MAXsa 10 ControllerSafety Precaution Figure A.1 MAXsa 10 Connections Interfacing to the MAXsa 10 CON TrollerFigure A.3 Figure A.4 Controlling NON-LINCOLN Equipment Shutdown Inputs Stop InputFigure A.6 Connection Diagram Single ARC System Operation Safety PrecautionsDesign Features Definitions of Welding ModesGeneral Functional Description Recommended Processes and EquipmentGeneral Physical Description Common Basic Equipment Packages200 Setting Feed FORWARD/REVERSE POWER-UP SequenceWire Feeder Setup Balance Adjust Changing and Setting Weld ModesFrequency Adjust Offset AdjustMultiple ARC Configuration Weld Mode SearchingSearching for a Weld Mode Table B.1 Phase Relationship ARCStart Options Operation Arc Delay TimeWeld Sequence Start OptionsDownslope Time END OptionsEND Options Operation Parameter Definition Accessing the Setup MenuAccess Preference Change Preference SelectionUser Defined Parameters Parameter Definition Hot-Inch Touch Sense Option Wire Drive Gear Ratio100 View Diagnostics? Shutdown 2 Function Select102 View Fatal Logs 107 View Power Source ProtocolParameter Definition 101 View Event Logs 103 View Software Version Information505 Setup Menu Lock 503 Memory Button Disable504 Mode Select Panel Lock Parameter Definition 502 Memory Change LockoutTouch Sense Parameter Definition 506 Set User Interface Passcode509 UI Master Lockout Lockout / SecurityMaking a Weld Figure B.7 Making a WeldMulti Procedure Welding Using the Memory OptionNaming a Saved Procedure Steel 1/8 Saving a Procedure to a Memory LocationRecalling a Procedure from a Memory Location CC DC +Optional Limit Setup Setting LimitsAccessories Follow these stepsPeriodic Maintenance Calibration Specification MaintenanceRoutine Maintenance Troubleshooting HOW to USE Troubleshooting GuideUsing the Status LED to Troubleshoot System Problems Table E.1Arclink System Error Codes Troubleshooting Verify correct sense lead connection Output Disabled Output Problems Troubleshooting Diagrams Enhanced DiagramDimension Print L13444Precaucion Warnung