OPTIONAL LIMIT SETUP

The Limits feature allows the operator to set minimum and maximum values for various parameters depending on the Weld Mode selected.

Each memory location may have a different set of limits, even if the Weld Mode is the same. For example: Memory Location 1 can be set for a maximum wire feed speed of 140”/min; Memory Location 2 may be set for a minimum of 100”/min and a maximum of 160”/min and Memory Location 3 may have no WFS limit set.

Set High

Value

Set Low

Limit

Low Limit

Limit

200

Hi=1050 Lo= 200

Weld Amps

Parameters are constrained by the machine limitations or by memory limits. When the Memory Limits are enabled the parameter will flash if an attempt is made to set a value outside of the prescribed limit (if less than the machine capabilities). The parameter will not flash if an attempt is made to exceed the machine limits.

NOTE: Weld Modes cannot be selected through the Limits Setup Menu. They must be chosen and saved before entering the Limits Menu.

SETTING LIMITS

1.Press and hold the desired Memory Button until the LED for that location begins to blink rapidly.

The MSP Display will read:

Memory 1

Set Limits

Parameter

Name

3.The Parameter Name on the MSP Display will flash to indicate it is ready to be changed. If no lim- its were previously set, the High and Low values are the limits of the Power Source

Press the Arc Start/End Options button to select that parameter.

Use the Mode Select Panel Control to adjust the High Limit (flashing).

Press the Arc Start/End Options button.

Use the Mode Select Panel Control to adjust the Value (flashing).

Press the Arc Start/End Options button.

Use the Mode Select Panel Control to adjust the Low Limit (flashing).

Press the Arc Start/End Options button.

Use the Mode Select Panel Control to select another Parameter Name (flashing) and repeat the above sequence until all Limits are set.

4.Press the selected Memory when all limits are set to desired values. The MSP Display will read:

Save

Li

mits

Yes

N

o

2.After 2 seconds the display will change to show the following items:

Memory Value

High Limit

Low Limit

Parameter Name

Use the Weld Mode Select or the Arc Start/End Options button to either save (yes) or discard (no) the changes.

MAXsa™ 10 CONTROLLER

Image 33
Contents Controller Safety Electric Shock can kill Welding and Cutting Sparks can Cause fire or explosion Précautions DE Sûreté Thank You Table of Contents Technical Specifications MAXsa 10 Controller InstallationSafety Precaution Figure A.1 MAXsa 10 Connections Troller Interfacing to the MAXsa 10 CONFigure A.3 Figure A.4 Controlling NON-LINCOLN Equipment Stop Input Shutdown InputsFigure A.6 Connection Diagram Single ARC System Design Features Safety PrecautionsOperation Definitions of Welding ModesGeneral Physical Description Recommended Processes and EquipmentGeneral Functional Description Common Basic Equipment Packages200 POWER-UP Sequence Wire Feeder SetupSetting Feed FORWARD/REVERSE Frequency Adjust Changing and Setting Weld ModesBalance Adjust Offset AdjustSearching for a Weld Mode Weld Mode SearchingMultiple ARC Configuration Table B.1 Phase Relationship ARCWeld Sequence Arc Delay TimeStart Options Operation Start OptionsEND Options END Options OperationDownslope Time Access Preference Change Accessing the Setup MenuParameter Definition Preference SelectionUser Defined Parameters 100 View Diagnostics? Wire Drive Gear RatioParameter Definition Hot-Inch Touch Sense Option Shutdown 2 Function SelectParameter Definition 101 View Event Logs 107 View Power Source Protocol102 View Fatal Logs 103 View Software Version Information504 Mode Select Panel Lock 503 Memory Button Disable505 Setup Menu Lock Parameter Definition 502 Memory Change Lockout509 UI Master Lockout Parameter Definition 506 Set User Interface PasscodeTouch Sense Lockout / SecurityFigure B.7 Making a Weld Making a WeldUsing the Memory Option Naming a Saved ProcedureMulti Procedure Welding Recalling a Procedure from a Memory Location Saving a Procedure to a Memory LocationSteel 1/8 CC DC +Setting Limits Optional Limit SetupFollow these steps AccessoriesMaintenance Routine MaintenancePeriodic Maintenance Calibration Specification HOW to USE Troubleshooting Guide TroubleshootingTable E.1 Using the Status LED to Troubleshoot System ProblemsArclink System Error Codes Troubleshooting Verify correct sense lead connection Output Disabled Output Problems Troubleshooting Enhanced Diagram DiagramsL13444 Dimension PrintPrecaucion Warnung