Lincoln Electric IM10023 Parameter Definition Hot-Inch Touch Sense Option, Wire Drive Gear Ratio

Page 26

B-11

 

OPERATION

B-11

 

 

 

 

 

 

USER DEFINED PARAMETERS (CONT.)

 

Parameter

Definition

 

 

 

 

P.15

Hot-Inch Touch Sense Option

 

This option allows enabling or disabling touch sense when feeding wire forward.

Disabled = Touch sensing is disabled when feeding the wire forward (default).

Enabled = Touch sensing is active when feeding the wire forward.

 

 

When enabled and feeding wire forward, the wire is electrically "hot" and waiting to short to the

 

 

plate. When a short occurs, the wire feed automatically stops and the flux hopper relay is acti-

 

 

vated until the feed forward button is released.

 

P.18

Wire Drive Gear Ratio

 

 

This option selects the Wire Drive Gear Ratio that will be used. This applies to the Cruiser dX

 

 

Tractor and MAXsa 10 only. The possible selectable values are read from the Wire Drive on

 

 

startup.

 

 

Note: Changing this value will cause the system to reset.

 

 

 

 

P.21

Shutdown 2 Function Select

 

 

This option allows selection of the Shutdown 2 input function on the control box. Normal

 

 

Shutdown = The Shutdown 2 input functions as a standard shutdown input that locks out all

 

 

input buttons (default) Output Disable = The Shutdown 2 input functions as a machine output

 

 

lockout to disable the welding circuit but still allow cold feeding of the wire.

 

 

 

 

P.23

Trigger Fan-Out

 

 

For Sub-Arc Lead Arc machines only. Allows the Lead Arc MAXsa10 to control all machine trig-

 

 

gers in a multi-arc system.

 

 

No = Only the machine connected to the MAXsa10 can be triggered on and off (default).

 

 

Yes = All machines in the system can be triggered on and off simultaneously.

 

 

 

 

P.30

Input Control

 

 

This option allows the front panel controls of the MAXsa 10 to be enabled/disabled. The remote

 

 

inputs are always functional when connected, but there may be applications where it is neces-

 

 

sary to disable the inputs on the pendent. Panel & Remote = All pendent buttons are enabled

 

 

(default). Panel Locked = The Start, Flux and feed buttons are disabled at the pendent. The

 

 

pendent's Stop button is always active and cannot be disabled.

 

 

 

 

P.80

Sense From Studs

 

 

Use this option for diagnostic purposes only. When power is cycled, this option is automatically

 

 

reset to False.

 

 

False = Voltage sensing is automatically determined by the selected weld mode and otherma-

 

 

chine settings (default).

 

 

True = Voltage sensing is forced to "studs".

 

 

 

 

P.99

Show Test Modes?

 

 

Most power sources contain weld modes used for calibration and test purposes. By default, the

 

 

machine does not include test weld modes in the list of weld modes that are available to the

 

 

operator. To manually select a test weld mode, set this option to "Yes". When the power source

 

 

is turned off and back on again, the test modes will no longer appear in the mode list. Test weld

 

 

modes typically require the machine output to be connected to a grid load and cannot be used

 

 

for welding.

 

 

 

 

P.100

View Diagnostics?

 

 

Diagnostics are only used for servicing or troubleshooting the Power Wave system. Select "Yes"

 

 

to access the diagnostic options in the menu. Additional parameters will now appear in the

 

 

setup menu (P.101, P.102, etc).

 

 

MAXsa™ 10 CONTROLLER

Image 26
Contents Controller Safety Electric Shock can kill Welding and Cutting Sparks can Cause fire or explosion Précautions DE Sûreté Thank You Table of Contents Installation Technical Specifications MAXsa 10 ControllerSafety Precaution Figure A.1 MAXsa 10 Connections Interfacing to the MAXsa 10 CON TrollerFigure A.3 Figure A.4 Controlling NON-LINCOLN Equipment Shutdown Inputs Stop InputFigure A.6 Connection Diagram Single ARC System Operation Safety PrecautionsDesign Features Definitions of Welding ModesGeneral Functional Description Recommended Processes and EquipmentGeneral Physical Description Common Basic Equipment Packages200 Setting Feed FORWARD/REVERSE POWER-UP SequenceWire Feeder Setup Balance Adjust Changing and Setting Weld ModesFrequency Adjust Offset AdjustMultiple ARC Configuration Weld Mode SearchingSearching for a Weld Mode Table B.1 Phase Relationship ARCStart Options Operation Arc Delay TimeWeld Sequence Start OptionsDownslope Time END OptionsEND Options Operation Parameter Definition Accessing the Setup MenuAccess Preference Change Preference SelectionUser Defined Parameters Parameter Definition Hot-Inch Touch Sense Option Wire Drive Gear Ratio100 View Diagnostics? Shutdown 2 Function Select102 View Fatal Logs 107 View Power Source ProtocolParameter Definition 101 View Event Logs 103 View Software Version Information505 Setup Menu Lock 503 Memory Button Disable504 Mode Select Panel Lock Parameter Definition 502 Memory Change LockoutTouch Sense Parameter Definition 506 Set User Interface Passcode509 UI Master Lockout Lockout / SecurityMaking a Weld Figure B.7 Making a WeldMulti Procedure Welding Using the Memory OptionNaming a Saved Procedure Steel 1/8 Saving a Procedure to a Memory LocationRecalling a Procedure from a Memory Location CC DC +Optional Limit Setup Setting LimitsAccessories Follow these stepsPeriodic Maintenance Calibration Specification MaintenanceRoutine Maintenance Troubleshooting HOW to USE Troubleshooting GuideUsing the Status LED to Troubleshoot System Problems Table E.1Arclink System Error Codes Troubleshooting Verify correct sense lead connection Output Disabled Output Problems Troubleshooting Diagrams Enhanced DiagramDimension Print L13444Precaucion Warnung