Lincoln Electric IM10023 manual Figure B.7 Making a Weld

Page 30

B-15

OPERATION

B-15

 

 

 

MAKING A WELD

Once the necessary parameters have been set and the desired Weld Mode selected:

Press the START BUTTON to begin welding.

The ARC ESTABLISHED INDICATOR will ‘flash’ as the wire feeds towards the work piece to show that OCV is present and switch to ON when the arc is lit.

If “Start” parameters have been set they will be in effect for the specified time and then the Weld Mode parameters will take effect.

The two upper displays will indicate the “actual” parameters as the weld progresses.

If the TRAVEL function is selected it will begin moving as prescribed in the P.12 Parameter set- ting.

Press the STOP BUTTON to end the weld.

If “End” parameters have been set, they will take effect for the specified time.

If the TRAVEL function is selected it will stop mov- ing as prescribed in the P.12 Parameter setting.

The ARC ESTABLISHED INDICATOR will go OFF when the power source output is disabled (after Burnback).

The displays will return to the idle state in prepara- tion for the next weld.

FIGURE B.7 - MAKING A WELD

ARCSE

TABL

ISHED

INDI

OCAT

R

200

30.5

58

Steel 1/8” CC DC+

START BUTT NO

STO P BUTT NO

MAXsa™ 10 CONTROLLER

Image 30
Contents Controller Safety Electric Shock can kill Welding and Cutting Sparks can Cause fire or explosion Précautions DE Sûreté Thank You Table of Contents Installation Technical Specifications MAXsa 10 ControllerSafety Precaution Figure A.1 MAXsa 10 Connections Interfacing to the MAXsa 10 CON TrollerFigure A.3 Figure A.4 Controlling NON-LINCOLN Equipment Shutdown Inputs Stop InputFigure A.6 Connection Diagram Single ARC System Operation Safety PrecautionsDesign Features Definitions of Welding ModesGeneral Functional Description Recommended Processes and EquipmentGeneral Physical Description Common Basic Equipment Packages200 POWER-UP Sequence Wire Feeder SetupSetting Feed FORWARD/REVERSE Balance Adjust Changing and Setting Weld ModesFrequency Adjust Offset AdjustMultiple ARC Configuration Weld Mode SearchingSearching for a Weld Mode Table B.1 Phase Relationship ARCStart Options Operation Arc Delay TimeWeld Sequence Start OptionsEND Options END Options OperationDownslope Time Parameter Definition Accessing the Setup MenuAccess Preference Change Preference SelectionUser Defined Parameters Parameter Definition Hot-Inch Touch Sense Option Wire Drive Gear Ratio100 View Diagnostics? Shutdown 2 Function Select102 View Fatal Logs 107 View Power Source ProtocolParameter Definition 101 View Event Logs 103 View Software Version Information505 Setup Menu Lock 503 Memory Button Disable504 Mode Select Panel Lock Parameter Definition 502 Memory Change LockoutTouch Sense Parameter Definition 506 Set User Interface Passcode509 UI Master Lockout Lockout / SecurityMaking a Weld Figure B.7 Making a WeldUsing the Memory Option Naming a Saved ProcedureMulti Procedure Welding Steel 1/8 Saving a Procedure to a Memory LocationRecalling a Procedure from a Memory Location CC DC +Optional Limit Setup Setting LimitsAccessories Follow these stepsMaintenance Routine MaintenancePeriodic Maintenance Calibration Specification Troubleshooting HOW to USE Troubleshooting GuideUsing the Status LED to Troubleshoot System Problems Table E.1Arclink System Error Codes Troubleshooting Verify correct sense lead connection Output Disabled Output Problems Troubleshooting Diagrams Enhanced DiagramDimension Print L13444Precaucion Warnung