Operation

Adjusting regulator

This compressor is provided with an internal regulator that controls the output pressure of two female quick connect couplers. Regulated pressure will be equal to or less than tank pressure depending on user setting.

Regulator (A)

Regulated Pressure

Gauge (B)

Fig. 7

To adjust regulated pressure (see Fig. 7):

1.Pull regulator knob out (A).

2.To increase pressure, turn clockwise.

3.To decrease pressure, turn counter clockwise.

4.When desired pressure is set, push regulator knob in to lock pressure.

5.Regulated pressure gauge is displayed as (B).

Connecting Air Supply

WARNING Firmly grasp the hose in hand when installing hoses. If hose is not held firmly or correctly installed hose may whip and injure personnel in the operating area.

Installing Hoses (See Fig. 8):

1.Grasp the hose at the quick connect plug and push the plug into the quick connect body. Coupler will snap into place.

2.Grasp the hose and pull to ensure coupler is seated.

Fig. 8

Operating Temperatures

Operating temperatures are between 32°F and 104°F (0°C and 40°C). If operating outside recommended temperatures, unit may have difficulity starting and will cause additional wear on components.

WARNING Disconnect the compressor from the power source, drain air tanks and allow it to cool before making adjustments, moving the compressor, leaving the work area, performing maintenance or storing the compressor. Such precautionary safety measures reduce the risk of injury.

Shutting down the compressor

1.Move On/Off switch to the OFF position.

2.Turn regulator until outlet pressure gauge reads 0 psi.

3.Remove hose and assembly. See disconnecting air supply below.

4.Drainairfromtheairtanksbyreleasingairbypulling the safety release valve.

5.Oncetheairtankpressureisunder20psi,openthe drain valve on the control panel to drain moisture from the tanks (See draining tanks on page 12).

6.Allow the compressor to cool down before storing.

Disconnecting Air Supply

Disconnecting Hoses (See Fig. 8)

1.Ensure regulated pressure gauge reads 0 psi (0 kPa).

2.Pull coupler on quick connect body back to release quick connect plug on hose.

11

Image 11
Contents CET3-10 CET4-20 CET4-20W Increases the risk of injury General Safety RulesWork Area Respect the compressor as a working implementFollow all recommendations for sizes of hoses, fittings Particulates in oil may reduce compressor lifeRisk of fire Page Safety Rules for Electric Compressors Specifications CET4-20 Functional Description and SpecificationsSpecifications CET3-10 Specifications CET4-20W Grounding Assembly / Installation Directions for Installing Wheels Lubrication and OilElectric Motor Initial Set-Up Break-in ProcedureExtension Cords Preparation for UseOperation Disconnecting Air Supply Adjusting regulatorConnecting Air Supply Operating TemperaturesMaintenance Compressor Some CleaningStorage Loading/unloadingSolution. Do not overtighten Trouble shootingProblem Symptoms Resolution Trouble shooting Trouble shooting Espace de travail Consignes générales de sécuritéConserver CES Instructions Page De réduire la durée de vie du compresseur Conservez CES Instructions Consignes de sécurité pour les CompressEUrs électriquesDescription fonctionnelle et spécifications Dimensions du produitType d’entraînement Direct Maintenance Oil Spécifications CET4-20W CET4-20W only Voir Assemblage / InstallationLubrification ET Huile Mise À LA TerreMoteur Électrique Cordons DE RallongeRallonge Préparation EN VUE DE L’EMPLOISurfaces Très Chaudes FonctionnementMise EN Marche DU Compresseur Coupure DU Moteur PAR LE Protecteur ThermiqueArrêt DU Compresseur Réglage DU RégulateurConnexion DE L’ALIMENTATION EN AIR Températures DE FonctionnementDrainage DES Réservoirs Service Pour faire la vidange d’huile VoirDes pièces de rechange pouvant être installées par De fuites d’huile Recommandation Tous les Une fois par Toutes lesRangement Chargement / DéchargementRemarque Diagnostic DES PannesProblème Symptômes Résolution Diagnostic DES Pannes Diagnostic DES Pannes Guarde Estas Instrucciones Normas generales de seguridad para herramientas neumáticasDespués de usarlo Page Cuando utilice una herramienta eléctrica a Normas DE Seguridad Para Compresores EléctricosEspecificaciones CET4-20 Descripción funcional y especificacionesEspecificaciones CET3-10 Especificaciones CET4-20W Conexión a Tierra Ensamblaje E InstalaciónLubricación Y Aceite Instrucciones DE Instalación RuedasPreparación inicial Procedimiento de asentamiento Cordones DE ExtensiónPreparación Para EL USO Motor EléctricoSuperficies Calientes UtilizaciónArranque DEL Compresor Desconexión Térmica DEL MotorApagado DEL Compresor Ajuste DEL ReguladorConexión DEL Suministro DE Aire Temperaturas DE FuncionamientoEn el compresor Véase Fig MantenimientoDrenaje DE LOS Tanques Coloque el compresor en una superficie niveladaSi hay fugas de aceite AlmacenamientoCarga Y Descarga Recomendación Diariamente Semanalmente Cada 200 horasJabonosa. No los sobreapriete Resolución DE ProblemasProblema Síntomas Resolución Resolución DE Problemas Resolución DE Problemas Page Limited Warranty of Bosch Portable and Benchtop Power Tools