Maintenance
Service
Preventive maintenance
!WARNING performed by unauthorized per so n nel may result in misplacing of internal wires and components which could cause serious hazard. We recommend that all tool service be performed by a Skil Factory Service Center or Autho rized Skil Service Station.
TOOL LUBRICATION
Your Skil tool has been properly lubricated and is ready to use. However it is recommended that the gears be relubricated only with Skil lubricants: No. 80111 (8 oz. tube), No. 80112 (pint) or No. 80113 (1/2 gal. can).
Always check the oil level before using the saw. To check and add oil: Remove plug from power source and
place the saw’s foot on a horizontal surface. Remove oil plug using the same wrench used to remove the saw blade. The oil level should never be below bottom threads in the housing. When adding oil, fill until oil starts to run out of oil hole at arrow on housing and replace oil plug.
NOTE: If oil is extra dirty or thick, replace the plug and run the saw for one minute to warm up the oil. Then remove oil plug and turn saw upside down, to remove all oil. Fill housing with kero sene. Replace plug and run for one minute to flush out the gear housing. Drain out the kerosene and add fresh Skil lubricant. With a new saw, change the oil after the first ten hours of use.
CARBON BRUSHES
The brushes and commutator in your tool have been engineered for many hours of dependable service. To maintain peak ef iciencyf of the motor, we recommend every two to six months the brushes be examined. The brushes should be free from dust and dirt. Brushes should be replaced when they have worn down to 3/16" in length. The brushes should slide freely in and out of the holders without sticking.
To check brushes: Disconnect plug from power source. Unscrew the brush caps on the
motor housing and lift out the brushes; note which way they face, so that the brushes can be returned to their original position. Clean the brush holder openings with com pressed air or a clean cloth and replace the brushes and caps.
Only genuine Skil replacement brushes specially designed for your tool should be used.
BEARINGS
After about
Cleaning
To avoid accidents always dis connect the tool from the power supply before cleaning or
performing any main tenance. The tool may be cleaned most effectively with compressed dry air. Always wear safety gog gles when cleaning tools with compressed air.
Ventilation openings and switch levers must be kept clean and free of foreign matter. Do not at tempt to clean by inserting pointed objects through openings.
Certain cleaning agents ! CAUTION and sol vents damage
plastic parts. Some of these are: gasoline, carbon tetrachlo ride, chlo rinated cleaning solvents, ammonia and house oldh detergents that contain ammonia.
CARE OF BLADES
Blades become dull even from cutting regular lumber. If you find yourself forcing the saw forward to cut instead of just guid ngi it through the cut, chances are the blade is dull or coated with wood pitch.