2.Turn regulator knob clockwise to increase pressure and stop when desired pressure is reached.
Risk of unsafe operation. If any unusual noise or vibration is noticed, stop the compressor immediately and have it checked by a trained service technician.
The compressor is ready for use.
MAINTENANCE
Customer Responsibilities
| Before | Daily | See tank |
| each use | or after | warning |
|
| each | label |
|
| use |
|
Check Safety Valve | X |
|
|
Drain Tank |
| X |
|
Remove tank from service |
|
| X(1) |
1- For more information, call our Customer Care Center at
Risk of unsafe operation. Unit cycles automatically when power is on. When performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts. Personal injuries can occur. Before performing any maintenance or repair, disconnect power source from the compressor and bleed off all air pressure.
NOTE: See Operation section for the location of controls.
To Check Safety Valve
Risk of Bursting. If the safety valve does not work properly,
Risk from Flying Objects. Always wear certified safety equipment: ANSI Z87.1 eye protection (CAN/CSA Z94.3) with side shields.
Before starting compressor, pull the ring on the safety valve to make sure that the safety valve operates freely. If the valve is stuck or does not operate smoothly, it must be replaced with the same type of valve.
To Drain Tank
Risk of Unsafe Operation. Air tanks contain high pressure air. Keep face and other body parts away from outlet of drain. Use ANSI Z87.1 eye protection (CAN/CSA Z94.3) when draining as debris can be kicked up into face.
Risk from noise. Use ear protection [ANSI S12.6 (S3.19) hear- ing protection] as air flow noise is loud when draining.
NOTE: All compressed air systems generate condensate that accumulates in any drain point (e.g., tanks, filter, aftercoolers, dryers). This condensate contains lubricating oil and/or substances which may be regulated and must be disposed of in accordance with local, state, and federal laws and regulations.
1.Set the On/Off switch to "Off".
2.Turn the regulator knob counterclockwise to set the outlet pressure to zero.
3.Remove the air tool or accessory.
12 - ENG