Woodstock W1772 W1773 220V/440V Phase Operation, Phase Converter, W1773 Electrical Specifications

Page 14

W1772/W1773 37" Drum Sander

ELECTRICAL

The machine must be properly set up before it is safe to operate. DO NOT connect this machine to the power source until instructed to do so in the "Power Connection" portion of this manual.

W1773 220V/440V 3-

Phase Operation

The Model W1773 is prewired for 220V 3-phase operation, but may be rewired for 440V 3-phase operation (see Page 13).

This machine must be hardwired to a locking shutoff switch by a qualified electrician. Hardwiring involves a permanent installation with conduit runs that can only be accomplished safely by a qualified electrician. As always, observe all applicable electrical codes when connecting this machine to power.

This machine must be grounded! Verify the ground before connecting this machine to the power source.

Phase Converter

The power from the manufactured power leg (wild wire) of a phase converter fluctuates, which may damage elec- trical components if connected to the wrong incoming power terminal. If you must use a phase converter for 3-phase power, only connect the "wild wire" to the L1 terminal. The wire from the L1 terminal can handle some fluctuation because it goes directly to the motor. The power going to the L2 and L3 terminals connects to the controls and must be consistent to prevent damage.

Figure 3. Locking shutoff switch.

Attempting to connect this machine to the power source without a qualified electrician greatly increases the risk of electrocution, fire, or machine damage.

W1773 Electrical

Specifications

Voltage

Amp Draw

Min. Circuit Size

Connection

Cord

Extension Cord

220V

44.3

60A

Hardwire

Conduit Setup

N/A (Hardwire Only)

440V

22.15

30A

Hardwire

Conduit Setup

N/A (Hardwire Only)

-12-

Image 14
Contents Drum Sander Page Contents Introduction Woodstock Technical SupportIntroduction Introduction Introduction Introduction Controls and Features Safety Standard Safety Instructions Always Lock Mobile Bases if Used Before Operating Machinery Additional Safety for Drum Sanders Electrical W1772 Single-Phase OperationW1772 Electrical Specifications W1773 Electrical Specifications W1773 220V/440V Phase OperationPhase Converter Rewiring W1773 to To rewire the Model W1773 for 440V operation, do these stepsUnpacking SetupItems Needed for Setup InventoryAssembly If you do not hear any scraping sounds go to StepControl panel mounting bolts Machine Placement W1772/W1773 minimum working clearancesTo place the sander in a permanent location, do these steps Lifting SanderMounting to Shop Floor Dust Collection Power ConnectionTo connect the sander to the power source, do these steps Recommended CFM at SanderGear Oil Check To check the gear oil, do these stepsTest Run To test run the drum sander, do these stepsRecommended Adjustments SETGeneral OperationsControl Panel Sanding Drums Start Button Starts the sanding drumsVariable Speed To adjust the conveyor speed, do these stepsDepth of Cut To set the depth of cut, do these stepsTo sand a workpiece, do these steps Using the Amp Draw MeterSanding Sanding Tips Choosing Sandpaper Grit ClassPaper Replacement To change the paper, do these stepsDrum Sander Accessories Lubrication MaintenanceCleaning Step Lubricating gear boxTo make the gauge blocks, do these steps ServiceGauge Blocks Belt Service To adjust V-belt tension, do these stepsBearing Replacement To align the pulleys, do these stepsThat no obstructions prevent bearing lubrication Pages 38Conveyor Tensioning Tracking To tension the conveyor, do these stepsTracking To track the conveyor, do these stepsDrum Adjustments Adjusting Drums Perpendicular to Feed DirectionFront and rear drum Adjustment locations Loosen the front drum pillow bearing lock nuts FigureAdjusting Drum Height & Drum-to-Conveyor Parallelism Rear right sanding drum micro Adjusting knob Loosen the front drum pillow bearing lock nuts ,Pressure roller adjustment Nuts Pressure Roller HeightDust Scoops To adjust a dust scoop, do these stepsScale Pointer Calibration Table Lift ScewsTo adjust the table lift screws, do these steps Marking sprocket tooth ChainW1772/W1773 Wiring Overview Emergency stop bar limit SwitchW1772/W1773 control panel wiring W1772/W1773 Control PanelW1772 Electrical Box 220V, 1-Ph W1772 electrical boxW1772 Electrical Box Wiring 220V, 1-Ph FiguresW1772 sanding drum motor Wiring and start capacitors W1772 Sanding & Feed MotorsW1773 Electrical Box 220V, 3-Phase W1773 Electrical Box Wiring 220V, 3-Phase FiguresW1773 Electrical Box 440V, 3-Phase W1773 440V 3-phase electrical box wiringW1773 Electrical Box Wiring 440V, 3-Phase Figures 66W1773 220V sanding drum motor Wiring W1773 Sanding Drum MotorW1773 220V feed motor wiring W1773 Feed MotorTroubleshooting Moving parts have come to a complete stopMachine Operations Parts Frame Parts BreakdownFrame Parts List PART# DescriptionParts Breakdown Conveyor Parts List Roller & Drum Parts Breakdown XPK55MMicro-Adjustment Breakdown Electrical Components Electrical Parts List CurrentsensorLabel Placement Warranty Registration CommentsBOX BELLINGHAM, WA Warranty