Carrier 50VQP084-300 specifications A50-8436, 50VQP084-150 Unit Dimensions

Page 4

ALL CONFIGURATIONS REQUIRE SERVICE ACCESS AREA SHOWN BELOW

 

 

 

 

 

19.3

 

 

 

 

 

F

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

19.3

 

 

 

 

 

 

 

F

 

 

 

 

 

 

 

 

 

 

AIR OUT

NRP

 

NRP

AIR OUT

 

 

 

 

 

BSP

 

 

 

 

 

 

 

a50-8436

 

 

 

 

 

 

 

BSP

 

 

T

 

 

 

 

NRP

 

RETURN AIR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RETURN AIR

 

 

 

 

S

 

4

 

 

 

 

C

 

 

 

 

 

 

 

 

1

 

 

 

2

 

NRP

 

Q

 

5

 

 

 

 

R

 

 

 

 

 

 

 

U

 

 

 

 

 

3

 

NRP

4

Control Box

 

 

 

02

CAP+MSP

 

 

 

 

 

 

Control Box

3

 

3

 

4

 

 

 

 

 

3 L

P

 

 

 

N

 

 

4 5

01

2

 

 

NRP

1

 

 

M

 

 

 

 

 

 

 

 

 

M K

 

 

 

 

 

 

L

 

CSP+CAP+MSP

K

 

CSP

 

 

 

 

 

 

 

 

 

 

ANOTE 5

 

 

REAR RETURN TOP DISCHARGE

 

FRONT RETURN TOP DISCHARGE

4.3

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

RETURN AIR

 

 

 

 

 

 

 

BSP

 

 

 

 

F

 

 

 

 

 

 

 

 

E

 

 

 

BSP

 

 

 

BSP

 

 

 

AIR OUT

 

NRP

AIR OUT

 

 

 

 

 

4

 

NRP

 

 

 

 

 

 

 

 

 

 

 

 

5

 

1

 

 

 

 

 

 

 

 

 

RETURN AIR

 

 

 

 

 

NRP

 

 

NRP

4

3

 

4

 

 

 

 

2

 

 

 

CAP+MSP

 

 

5

 

 

 

Control Box

 

 

 

 

 

 

 

 

 

 

 

 

 

4

3

4

Control Box

 

 

 

2

 

5

 

 

 

 

4

 

 

 

 

 

 

3

4

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

4

5

 

CSP

 

 

NRP

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CSP+CAP+MSP

 

 

 

 

 

SIDE

 

 

 

 

 

 

 

SERVICE ACCESS

 

 

 

 

 

 

 

(SEE NOTE)

 

 

 

 

SERVICE ACCESS

 

REAR RETURN FRONT DISCHARGE

 

 

 

 

91 CM

 

 

 

 

 

 

 

 

 

FRONT RETURN REAR DISCHARGE

FRONT AND BACK

 

 

 

 

LEGEND

BSP — Blower Service Panel

CAP — Control Access Panel

CSP — Compressor Service Panel

MSP — Motor Service Panel

NRP Non-Removable Panel

NOTES:

1.All dimensions in centimeters.

2.Units require 0.9 m clearance for water connections, CAP, CSP, MSP, and BSP service access.

3.Overall cabinet height dimension does not include duct flange when in top discharge configuration.

4.Overall cabinet width dimension does not include filter rack and duct flange when on front or back dis- charge configuration.

5.Side service access must be 0.9 m on either side that connections are made. If no connections are made on a side, then service access can be 15 mm minimum.

6.While access to all removable panels is not required, installer should take care to comply with all building codes and allow adequate clearance for future field service.

7.Water inlet and water outlet connections are available on either side (left or right) of the unit. Two MPT plugs are shipped loose in a plastic bag tied to the water leg in front of the unit. Installer must plug water inlet/outlet side not being connected to.

8.Condensate drain is available on either side (left or right) of unit. Drain hose and drain connection will be tied inside the unit. Installer must untie the drain hose and connect to the condensate drain hole of installer’s choice.

9.Electrical access is available on either side (left or right) of unit and is also available (left or right) in the front of the unit.

10.Overall depth — add 7.9 cm for 2.5 or 5 cm filter. Add 13 cm for 10 cm filter.

1

2

3

4

5

CONNECTIONS

50VQP084-120

50VQP150

Water Inlet (See Note 7)

11/2 in. FPT

2 in. FPT

Water Outlet (See Note 7)

11/2 in. FPT

2 in. FPT

Condensate Drain (See Note 8)

1 in. FPT

1 in. FPT

High Voltage Access (See Note 9)

13/8 in.

13/8 in.

Low Voltage Access (See Note 9)

7/8 in.

7/8 in.

 

 

OVERALL

 

DISCHARGE

 

 

WATER

 

 

ELECTRICAL

 

 

RETURN AIR

 

 

 

 

CONNECTIONS (cm)

 

 

 

 

CONNECTIONS (cm)

 

 

CABINET (cm)

 

CONNECTIONS (cm)

 

 

KNOCKOUTS (cm)

 

 

UNIT

Duct Flange

 

 

 

 

 

(Using Return Air Opening)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50VQP

A

B

 

C

D

E

 

K

L

M

 

 

 

 

 

 

S

T

 

 

 

 

Supply

Supply

F

1-Water

1-Water

3-

N

O1

O2

P

Q

R

Return

Return

U

V

 

Depth

Width

 

Height

 

 

Width

Depth

 

Inlet

Outlet

Condesate

 

 

 

 

 

 

Depth

Height

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

084-120

86.4

134.9

 

200.7

44.5

44.6

45.1

78.7

7.6

68.6

65.1

78.7

96.4

87.7

2.5

7.6

121.9

82.2

113.3

6.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150

86.4

134.9

 

200.7

54.4

44.6

45.1

78.7

7.6

68.6

65.1

78.7

96.4

87.7

2.5

7.6

121.9

82.2

113.3

6.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 2 — 50VQP084-150 Unit Dimensions

4

Image 4
Contents Contents Safety ConsiderationsInstallation General50VQP Unit Physical Data 406442 78250VQP084-150 Unit Dimensions A50-843650VQP168-300 Unit Dimensions A50-8437A50-8467 A50-8466A50-8468 A50-8469 A50-8470A50-8471 A50-8472A50-8476 A50-8477A50-8478 A50-8479A50-8482 A50-8485A50-8483 A50-8484A50-8486 Trap Condensate DrainField Power Supply Wiring Water Quality Guidelines A50-8438 50VQP084-168 Unit with Complete C Control TypicalA50-8439 50VQP084-168 with Deluxe D Control TypicalJ6J5 AL1J1 J8 50VQP Unit Electrical Data Dual Point Power Unit 50VQP Unit Electrical Data Standard UnitField Control Wiring PRE-START-UPA50- 6268tf.tif A50-8441Page 50VQP084 Blower Performance Data 50VQP096 Blower Performance Data 412 455 492 526 563 595 628 658 687 718 745 421 459 499 533 569 600 633 663 691 722 749441 478 513 549 581 614 644 672 703 730 759 456 495 529 561 595 625 656 685 712 741 76750VQP120 Blower Performance Data 511 544 578 608 637 668 695 722 748 776 800 825 849 874 897 526 561 592 621 649 679 706 732 758 785 809 833 857 882544 575 605 633 661 691 717 742 767 794 818 842 867 890 555 589 618 646 676 702 728 753 779 803 827 850 875 89850VQP150 Blower Performance Data 581 613 646 678 706 735 763 791 817 842 867 889 912 935 958 598 623 656 687 715 744 772 799 825 850 872 896 919 942 963605 637 666 697 727 755 783 809 835 858 882 905 928 951 973 618 647 678 708 738 766 793 819 844 867 891 914 937 959 98050VQP168 Blower Performance Data 50VQP192 Blower Performance Data BkW 3020.8 Sheave/Mtr 50VQP240 Blower Performance Data 605 633 660 689 714 739 763 790 813 836 858 882 904 50VQP300 Blower Performance Data 538 574 609 640 673 703 733 761 788 812 838 863 888 912 553 588 620 653 685 715 744 771 796 822 847 872 896568 602 633 666 697 726 755 782 806 832 857 881 904 581 613 646 678 706 735 763 791 817 842 867 889Deluxe D Control Jumper Settings See Fig Complete C Control Jumper Settings See FigField Selectable Inputs DIP Switch Block S2 Accessory 1 Relay Options DIP Switch Block S2 Accessory 2 Relay OptionsSTART-UP Operating LimitsUnit Start-Up Cooling Mode Unit Start-Up Heating ModeWater Temperature Change Through Heat Exchanger 50VQP Unit Operating LimitsApproximate Fluid Volume L Per 30 M of Pipe Antifreeze Percentages by VolumeOperation Coaxial Water Pressure DropUnits with Aquazone Deluxe D Control Units with Aquazone Complete C ControlComplete C and Deluxe D Board System Test Complete C Control LED Code Fault Descriptions Service Aquazone Deluxe D Control LED IndicaRefrigerant Charging TroubleshootingAir Coil Fan Motor Removal A50-8163 FP1 and FP2 Thermistor LocationTroubleshooting Unit Does Not Operate Page Page Copyright 2010 Carrier Corporation Catalog No Form 50VQP-C1SI 11-1050VQP START-UP Checklist II. START-UPBook Catalog No Form 62AQ-1SI Pg CL-1 Replaces New TabHeating Cycle Analysis Cooling Cycle Analysis