Compact Station TKS-CS - Operating Instructions

5 Functional Description

PV.IcX

PV.SuN

 

TKS-CS.1000

 

 

max. 1 to 8

optional

 

 

 

 

 

 

PV.LoG-MH

 

 

 

 

PV.IcX

 

Transformer

 

 

 

max. 1 to 8

 

 

 

 

Transformer-

 

 

 

 

 

Monitoring

 

 

PV.500-MH

 

 

 

 

 

~

PV.500-MH

 

Transfer station

 

 

 

 

 

 

 

 

~

 

Radio and ripple

 

 

 

 

control /

 

 

 

 

power utility

 

 

 

TKS-CS.500

interface

 

PV.IcX

PV.SuN

 

4 x relay

Switchgear

 

 

Energy meter

max. 1 to 8

optional

 

 

 

 

 

 

 

PV.LoG-MH PV.ControL

Transformer

Internet

connection

Monitoring

Transformer-

PV.500-MH

~

Figure 10 - Equipment diagram (example)

CAN bus, max. 2 x 500 m

FO, ring max. 4 km

Modbus/RS485, max. 2 x 500 m Ethernet/COM server, max. 80 m Power cable

RS485/current-voltage transformer

The station equipment is configured in accordance with the required nominal output.

One or two Protect PV inverters can be connected to a compact station TKS-CS.

The PV.Control or Skycontrol unit is adapted to the power station capacity and the local feed conditions.

Further functional information can be found in the Protect PV Inverter Operating Instructions (BAL).

Page 16 of 39

8000043213 BAL

Image 16
Contents TKS-CS Revision Service Status Revision Date NameTable of Contents Decommissioning and Dismantling Mailservice.aegpss@aegps.com General Information ValidityAppropriate Use List of AbbreviationsInstallation Location SafetyLightning Protection Scope of Delivery Available to orderEquipment Specifications StructureDimension DimensionsLow-Voltage Box AC Connections Low-voltage boxes exampleISO Small Distribution Box Communications Cabinet PV LoG-MH Central Earthing SystemMedium-Voltage System No. H07V-KNameTransformer 3 4 5 4Functional Description Transfer stationTransport Suspended loads during transportAssembly Setting in PlaceHinge side of the door when closing InstallationConnection Design Torque Communication Interface PV.LoG-MH Medium-voltage system example Medium-Voltage Transformer Tightening Torques for Screw Connections Operation Start-upWorking with voltages up to 1 kV Servicing Contact with voltageResidual voltage from capacitors Contact with leakage currentHeat generation in resistors Insufficient ventilation of equipmentEntry of water into electrical equipment Obligation to Keep a Written Record Maintenance and Inspection Visual Inspection CleaningTesting/Measuring Functional TestReplacing the Axial Ventilator Care LubricationRotating parts Replacement Work Replacing the Transformer Testing after RepairsRepairs Roof structure Station frame Station roofReplacing the MV Switchgear Partial top view TKS-CS exampleMaintenance Schedule OngoingMonthly Every 6 monthsStoring Spare Parts AnnuallyEvery 2 years Every 4 yearsRemoving Connection Cables Decommissioning and DismantlingDismantling Disposal Statutory Provisions Chemical System ComponentsCompact Station TKS-CS Operating Instructions List of Tables List of Figures