Carrier 17EX specifications Index

Page 117

INDEX (cont)

Initial Start-Up,

Before, 45

Motor, 58

Initiation, Ice Build (Ice Build Control), 40

Input Equipment Service Parameters If Necessary, 55 Input/Output Module (PSIO), Processor/Sensor, 16 Input Service Con®gurations, 54

Input the Design Set Points, 54

Input the Local Occupied Schedule (OCCPC01S), 54 Input Time and Date, 55

Inputs,

(4-In/2-Out Module), 98

(Processor/Sensor Input/Output Module), 97 (Starter Management Module), 97

Spare Safety, 36

Inspect Refrigerant Float System (Scheduled Maintenance), 78

Inspect Relief Valves and Piping (Scheduled Maintenance), 78

Inspect the Control Center (Scheduled Maintenance), 76 Inspect the Heat Exchanger Tubes (Scheduled Maintenance), 82

Inspect the Starting Equipment (Scheduled Maintenance), 83 Inspect Water Piping, 50

Inspect Wiring, 50

Installation and Alignment, Disc Coupling, 59 Installation of New PSIO Module, 98

Installation, Common Point Sensor (Lead/Lag Control), 38 Instruct the Operator, 62

Instructions, Operating, 62

Insulation Resistance, Check (Inspect Wiring), 50 Interface (CCN), Carrier Comfort Network, 53 Introduction, 5

Job Data Required (Before Initial Start-Up), 45 Label, Chiller Identi®cation, 5

Lead/Lag Control, 38

Lead/Lag Operation (Lead/Lag Control), 39 Leak,

Test the Chiller, 46 Water, 82

Leak Rate, 67 LEDs,

Green (Control Modules), 96 Red (Control Modules), 96

LID Con®guration, Change If Necessary, 55 LID Default Screen Menu Items, 17

LID, Local Interface Device, 16

LID Operation and Menus, 16

Limited Shutdown, After, 63 Linkage, Checking Guide Vane, 68 Load Balancing (Lead/Lag Control), 40 Local Interface Device (LID), 16

Local Occupied Schedule (OCCPC01S), Input the, 54 Local Start-Up, 43

Log Off, To (Service Operation), 42 Log, Refrigeration, 63

Long-Term Storage (External Gear Storage), 81 Lubrication Cycle, 8

Lubrication Cycle,

Compressor, 8 External Gear, 9

Lubrication System, Check the, 76

Compressor (Instruct the Operator), 62 External Gear (Instruct the Operator), 62

Maintenance (Instruct the Operator), 62

Maintenance, Compressor Bearing, 82 Contact Seal, 68 Coupling, 78 External Gear, 82 General, 67

Motor, 78

Pumpout System, 83 Scheduled, 76 Weekly, 76

Major Leak, Test After Service, Repair or, 67

Manual Guide Vane Operation (Operating Instructions), 63 Manual Operation of the Guide Vanes, 58

Mechanical Starters (Check Starter), 53 Memory, Volatile, 11

Menu Items, LID Default Screen, 17 Menu Structure, 17

Menus, LID Operation and, 16 Messages, Checking the Display, 84 Mode, Chilled Water Recycle, 44

Modify Controller Identi®cation If Necessary, 55 Modify Equipment Con®guration If Necessary, 56 Module,

Installation of New PSIO, 98

Oil Differential Pressure/Power Supply, 16 Processor/Sensor Input/Output (Troubleshooting Guide), 97

Starter Management (Troubleshooting Guide), 97 Module (PSIO), Processor/Sensor Input/Output, 16 Module (PSIO), Processor/Sensor Input/Output (Troubleshooting Guide), 97

Module (SMM), Starter Management, 16

Module (SMM), Starter Management (Troubleshooting Guide), 97

Module Calibration, Oil Differential Pressure/Power Supply (Checking Pressure Transducers), 85 Module Operation, Notes on, 96

Module, 4-In/2-Out, 16, 98 Modules,

Attaching to Other CCN (Attach to Network Device Control), 41

Control, 96 Eight-Input, 16 Options (8-Input), 98

Replacing Defective Processor, 98

Monthly, Check Safety and Operating Controls, 76 Motor (Remove Shipping Packaging), 45

Motor Auxiliary Devices, 46

Motor Current Demand Setting, Calibrate, 61 Motor Electrical Connection, 45

Motor Handling/Rigging, 81 Motor Initial Start-Up, 58 Motor Maintenance, 78 Motor Pre-Start Checks, 51 Motor Replacement Parts, 83 Motor Rotation, Check, 58

Motor Sleeve Bearing and Pumpout Compressor Oil (Oil Changes), 78

Motor Starter, 5 Motor Storage, 81

Near Final Alignment (Chiller Alignment), 71 Network Device Control, Attach to, 41 Nitrogen, To Pressurizes With Dry, 68

Non-Ice Build Operations, Return to (Ice Build Control), 41 Normal Operating Conditions, Return Chiller to, 67 Notes on Module Operation, 96

117

Image 117
Contents Safety Considerations Start-Up, Operation, and Maintenance InstructionsContents OCCPC01S Input Service Congurations Piping Check Relief Devices Inspect WiringCoupling Maintenance Motor Maintenance Inspect Water PipingContents Introduction Abbreviations17EX Chiller Familiarization Certified PerformanceTypical 17EX Chiller Components Lubrication Cycle OIL Cooling CycleRefrigeration, Cycle Starters17EX Compressor Lubrication Cycle Denitions ControlsMajor PIC Components Panel Locations Temperature Sensors See Fig Pressure TransducersPIC Component Panel Location Processor Sensor Input/Output Module Control Center17EX Controls and Sensor Locations LID PICPsio Equip GND Ð GRDTewac LID Operation and Menus Fig PROCESSOR/SENSOR INPUT/OUTPUT Module PsioGeneral LID Service Screen Override Operations YES or no , on or OFF , etc. to select the desired state17EX LID Menu Structure Default ScreenAlarm History Service TableEquipment Configuration Control TestCarrier Comfort Network CCNHgbp Ð Hot Gas Bypass LIDChwr SetpointChws HgbpLID Display Data Description Range Units Reference Point Name Alarm HistoryExample 1 Ð STATUS01 Display Screen Menu Status SelectExample 2 Ð STATUS02 Display Screen Example 3 Ð STATUS03 Display ScreenMenu Status Example 4 Ð STATUS04 Display Screen Example 5 Ð Setpoint Display ScreenMenu Example 6 Ð Configuration Config Display Screen ECW Control OptionICE Build Termination LAG =2, Standby =3 Example 7 Ð LEAD/LAG Configuration Display ScreenExample 8 Ð SERVICE1 Display Screen Spare Alert Enable Example 9 Ð SERVICE2 Display ScreenExample 10 Ð SERVICE3 Display Screen Menu ServiceExample 12 Ð Maintenance MAINT02 Display Screen Example 11 Ð Maintenance MAINT01 Display ScreenDischarge Temperature Bearing TemperatureExample 13 Ð Maintenance MAINT03 Display Screen Example 14 Ð Maintenance MAINT04 Display ScreenDescription RANGE/STATUS Units Reference Point Name PIC System Functions Page Protective Safety Limits and Control Settings Capacity Overrides Page Page ECW Cent Capacity ICE Build Setpoint Example of Attach to Network Device Screen Example of Holiday Period Screen To Access the Service ScreensRecycle Sequence Fig START-UP/SHUTDOWNPage Job Data Required Before Initial START-UPEquipment Required MotorPage 17EX Leak Test Procedures Ð HFC-134a Pressure Ð Temperature C Ð HFC-134a Pressure Ð Temperature FTemperature F Temperature CDehydration Cold Trap Inspect Wiring Check Optional Pumpout Compressor Water Pip900 500 901 7000 1000 7001-14500 2500 Recommended Motor Fastener Tightening Torques External Gear Pre-Start ChecksExternal Gear Lubrication System Check Starter Mechanical StartersSOLID-STATE Starters Set Up Chiller Control Conguration Input the Design Set Points Ð To modify the setInput the Local Occupied Schedule OCCPC01S Change the LID Configuration if Necessary Surge Limiting orT1/P1 Full Load Points T2/P2 Load Surge Prevention Occurs TOO Soon Occurs TOO Late Increase P1 by Decrease P1 by50% Initial START-UP Charge Refrigerant into ChillerControl Test Menu Functions Tests to be Devices Tested PerformedDry Run to Test Start-Up Sequence Check Motor RotationInitial Motor START-UP Page Flange Nut Tightening Torques Low Speed Couplings Only Check Oil Pressure and Compressor Stop Calibrate Motor Current Demand SettingTo Prevent Accidental Start-Up Ð The PIC can be General RecommendationsOperator Duties Operating InstructionsStarting the Chiller Stopping the ChillerOperating the Optional Pumpout Compressor Pumpout and Refrigerant Transfer ProceduresPlant Chiller Serial No Chiller Model No Refrigerant Type Rear View Valve Condition RLAReturn Chiller to Normal Operating Conditions General MaintenanceChecking Guide Vane Linkage Ð Refer to Fig Contact Seal Maintenance Refer to ÐContact Seal Page Checking Preliminary Alignment Chiller AlignmentMeasuring Angular Misalignment Elevation Alignment Formula HOT Alignment Check Adjusting Angular Misalignment in PlanDoweling Correcting Parallel MisalignmentScheduled Maintenance Weekly MaintenanceCheck Safety and Operating Controls Monthly Changing the Oil FiltersCompressor OIL 17EX Chiller Oil SpecicationsPumpout Typical Float Valve Arrangement Sleeve Bearings Page Motor Riggings Inspect the Heat Exchanger Tubes Controls for Optional Pumpout Compressor Troubleshooting GuidePage MAINT02 MAINT01MAINT03 MAINT04Oilpd 1CR AUXOilt PICAutorestart in Progress Starts Limit ExceededOperation FaultPotential FREEZE-UP Failure to StopRunning Ð Demand Limited Running Ð Temp ControlChiller Protect Limit Faults LOW OIL Pressure Sensor Fault AlertAlert Autorestart PendingDESCRIPTION/MALFUNCTION Probable CAUSE/REMEDY Problem External Gear Troubleshooting GuidePossible Cause Ð Item NO.s Possible Cause ActionTemperature Voltage Resistance Drop Ð Thermistor Temperature F vs Resistance/Voltage DropTemperature Voltage Resistance Drop Ð Thermistor Temperature C vs Resistance/Voltage DropControl Modules Module SwitchModule Address Input Options ModuleProcessor/Sensor Input/Output Module Psio Fig Starter Management Module SMM FigGRD Switch Setting Options Module Installation of NEW Psio ModuleFour-In/Two-Out Module Fig Options Module4-In/2-Out Module Physical Data and Wiring SchematicsWeight Vessel SIZE² Additional Cooler WeightsCondenser Total Weight Condenser Charge 100Compressor Weight and Elbow Weight Additional Condenser WeightsDrive Component Weights 101Ð Total Motor Weight, English lb Ð Total Motor Weight, SI kg102 NIH Waterbox Cover Weights Marine Waterbox Cover WeightsApproximate Refrigerant HCFC-134a Charge 103Auxiliary Systems, Electrical Data Relief Valve Locations and Data104 105 Compressor Fits and Clearances106 Clearance Type DescriptionMeasure Tabulation Ð Impeller Clearances Open-Drive Compressors 10717FX 108 Temp 109Press Tewac110 111 112 General 113GND Ð Ground 114T1-T4 Terminal StripIndex Index Index Index Index Copyright 1997 Carrier Corporation

17EX specifications

The Carrier 17EX is recognized as an innovative air conditioning solution that combines efficiency with advanced technology. This model is designed to meet the increasing demands of residential and commercial cooling needs while maintaining environmental consciousness.

One of the standout features of the Carrier 17EX is its impressive Seasonal Energy Efficiency Ratio (SEER) rating. With a SEER rating that often exceeds 17, this unit ensures optimized energy consumption, significantly lowering operational costs for users. The incorporation of advanced compressor technology allows the system to adjust its cooling output based on the specific needs of the environment, thus providing both comfort and energy savings.

The Carrier 17EX utilizes a variable-speed inverter-driven compressor that enhances its performance and adaptability. This technology allows the air conditioning unit to operate at different speeds, intelligently adjusting to changing load conditions. As a result, the system runs more efficiently and quietly, providing a more consistent comfort level without the abrupt temperature swings associated with traditional units.

In addition to efficiency, the Carrier 17EX also prioritizes reliability and durability. The unit comes with a robust cabinet that protects the components from weather elements, ensuring longevity and consistent performance. The innovative design integrates a corrosion-resistant finish and robust insulation, which further enhances the unit's resilience in various environmental conditions.

For users concerned about indoor air quality, the Carrier 17EX includes advanced filtration systems designed to capture allergens and airborne particles. This feature is particularly beneficial for individuals with respiratory issues, ensuring that the air circulated within the space is clean and healthy.

Moreover, the Carrier 17EX is equipped with smart technology capabilities, allowing users to control their systems remotely through smartphones or other smart devices. This connectivity not only provides convenience but also empowers homeowners to optimize their energy use by adjusting settings on the fly, ensuring efficient operation even when they are away from home.

Overall, the Carrier 17EX stands out in the marketplace for its exceptional energy efficiency, advanced technology, and commitment to providing reliable and effective cooling solutions. Its combination of modern features makes it a preferred choice for those looking to enhance comfort while being mindful of energy consumption and environmental impact.