Last Beacon Type

This field displays the type of beaconing frames last detected on the monitored ring. When a beaconing condition begins, the content of the beacon frames varies depending on the condition that caused the beaconing process. Beacon frames are identified by a sub-vector which pinpoints the reason for the adapter’s transmission of beacon frames. Possible beacon types are:

Signal Loss Error

This beacon is transmitted by a station when it detects

 

signal loss from its upstream neighbor (most likely

 

because of a cable fault), enters monitor contention, and

 

monitor contention times out.

 

If a station detects signal loss while transmitting

 

streamingSignal beacons (the two following entries),

 

they will be changed to signalLossError beacons.

 

If a station detects a signal while transmitting

 

signalLossError beacons, they will be changed to

 

streamingSignalNotClaimToken (bit streaming) beacons.

Streaming Signal

This beacon is transmitted by a station when a

Not Claim Token

monitor contention time-out occurs in its adapter while it

 

is in monitor contention transmit mode, and it did not

 

receive any claim token MAC frames during the monitor

 

contention period.

Streaming Signal

This beacon is transmitted by a station when monitor

Claim Token

contention times out while its adapter was in monitor

 

contention mode (transmit or repeat), and one or more

 

claim token MAC frames were received during the

 

contention period. This indicates that monitor contention

 

could not be resolved within one second.

Recovery Mode Set

This beacon is transmitted when the ring has begun the

 

recovery process.

No Beacon Frames

There has been no beacon condition detected on the

Detected

ring yet.

Longest Beacon

Displays the duration of the longest beaconing occurrence, in an hours:minutes:seconds format.

Last Beacon

Displays the duration of the last beaconing occurrence, also in an hours:minutes:seconds format.

3-22

Viewing Ring-level Information

Image 72
Contents Trmmim Page Virus Disclaimer Restricted Rights Notice Applicable to licenses to the United States Government onlyContents Chapter Alarm Configuration Chapter Ring MapChapter Statistics Chapter Ring Security Configuration Appendix a Trmmim MIB StructureContents Using the Trmmim User’s Guide TrmmimWhat’s not in the Trmmim Guide Introduction to Spma for the TrmmimConventions Screen DisplaysIntroduction to Spma for the Trmmim Using the Mouse ButtonGetting Help FTPTrmmim Firmware Introduction to Spma for the Trmmim Trmmim Firmware Using the Trmmim Hub View Using the Hub ViewUsing the Trmmim Hub View Navigating Through the Hub ViewHub View Front Panel Trmmim Hub ViewUptime Time and DateDevice Name Device LocationUsing the Trmmim Hub View Using the Mouse in a Hub View Module Module Index FNB Bypass State Hub View Port Color Codes Port Display FormErrors FramesTotal Bytes Port TypeFNB Display Monitoring Hub Performance Using the Trmmim Hub View Checking Device Status and Updating Front Panel Info Name and LocationChecking Module Status ContactDate and Time Total RingsSpeed Fault Speed Fault LocationModule Name ModuleAdmin State Checking Port StatusPort Name Module/PortChecking Station Status Link State TimeInsertion Trap Station Name VendorUpstream Neighbor/Downstream Neighbor Physical Location PriorityPort Mapping Reverse MACsChecking Ring Port Status Configuring Station Name, Location, or PriorityFault State Time Media FaultClass Media TypeChecking Statistics Bytes LineBurst AbortManaging the Hub Managing the Hub at the Device LevelFind MAC Address Setting the Polling Intervals 12. The Find MAC Address Window13. Trmmim Polling Intervals Contact StatusDevice General Status Device ConfigurationPort Operational State StatisticsManaging the Hub at the Module Level Controlling Token Ring FNB Multiplexer ConnectionsINS Board Left ConnectRight Connect BypassControlling Token Ring Speed Clearing the Module FNB Configuration Window SelectionsControlling Token Ring MIM Management Mode Enabling All Ports on Token Ring ModulesAuto AUT Management MGTManaging the Hub at the Port Level Converting a Station Port to a Ring-out PortEnabling and Disabling Station and Ring Ports Removing a Station from the Ring Ring Map From the command line stand-alone mode Launching the Ring MapFrom the icon From the Hub ViewSelecting a Ring to Map Ring NameRing Map Speed StationsName UtilizationViewing Station-specific Information Quick Info Popup WindowBoard and Port DropSetting a Station Name Performance and ErrorsSetting a Station Drop Viewing Management Station ConfigurationCommands Error Status Open StatusError Active MonitorSetting the Statistics Calculation Mode Error Report TimerViewing Ring-level Information Viewing the Error Table Set Calculation Mode WindowError Table Window Total Errors Isolating ErrorsNon-Isolating Errors Changing the Station Labels Viewing Device Information Setting the Map Poll Interval Device Information WindowViewing Beacon History Active Monitor ChangesRing Purges Beacon EventsLast Beacon Type Longest BeaconLast Beacon Beacon Configuration 12. The Beacon Configuration Window Using the Find Options Searching by Station Name, MAC Address, Board/Port, or Drop 13. Sample Find WindowsFinding the Active Monitor on the Network Finding the Management Station on the Network Frames or Errors measured/Δ Time in seconds Accessing Other Spma Applications 14. Sample Find Highest and Lowest WindowsAlarm Configuration Spmarun e5alarms IP address community name Setting and Viewing Ring Alarms Alarm Configuration Setting and Viewing Station Alarms Setting a Ring Level AlarmAlarm Configuration Alarm Configuration Alarm Configuration Setting a Station Level Alarm Alarm Configuration Setting and Viewing Station Alarms Using Statistics StatisticsViewing the Ring Station List Spmarun e5stats IP Address community nameModule and Port Stn NameUpstream Addr Downstream AddrUsing the Reverse MAC Button Monitoring Ring and Station StatisticsRefreshing the Station List Creating a Pie Chart Creating a Graph or Meter Click mouse button 1 on Ring and Station Variables GeneralProtocols KBytesIsolating Errors Line ErrorsBurst Error AC ErrorNon-Isolating Errors Abort ErrorInternal Error Token Errors Frequency ErrorsStatistics Ring and Station Variables Ring Security Configuration About Ring SecurityLaunching the Security Configuration Window Ring Security ConfigurationSecurity Configuration Ring Selection window, -1, will appear Allowed Station List Allowed CountDisallowed Station List Disallowed CountSecurity Mode Options Disable SecurityEnable Security Allowed/Disallowed List Configuration Buttons Configuring Security Building the Allowed List AutomaticallyDeleting Stations from the Allowed or Disallowed Lists Station Addition WindowClearing All Entries in the Allowed or Disallowed List Clear List WindowChanging the Ring Security Mode RemoveIetf MIB Support Trmmim MIB StructureChassis MGR Protocol StackSnmp Agent Network One, Network TwoBrief Word About MIB Components and Community Names TelnetTrmmim MIB Structure Index Index-2 Index-3 Index-4