Miller Electric XMS 4000 manual Preparing Unit For TIG Welding, Setting Postflow only in Menu Full

Page 27

4-14. Preparing Unit For TIG Welding

P3

6

7

2 5 3

P7

4

To select TIG welding process, proceed as follows:

Follow safety precautions according to Section 1.

Prepare unit according Section 3.

Connect torch to the WORK connector 3 and the gas pipe to the gas connector 5.

Using a cable with a proper adapter, con- nect work clamp cable to the MIG gun con- nector.

If using a water-cooled torch, connect input coolant hose to blue quick connect fitting and return coolant hose to red quick con- nect fitting.

.Check coolant level after attaching

torch coolant hoses and running cool- er. Be sure coolant appears in upper half of indicator. Add coolant if neces- sary (see Section 3-9).

Turn unit On.

Allow time for unit to complete its start up cycle.

Set TIG welding process using P3 push button.

Purge air from torch gas hose using Torch Trigger (Manual Purge).

Select trigger mode using P7 push button (see Section 4-7).

Setting Initial And Final Amperage (only in MENU FULL)

To set initial and final amperage, proceed as follows:

Press P2 to enter SET UP menu.

Select MENU FULL on D1 and D2 (see Section 4-9).

Use E1 to change D1 to IN−A.

D2 value is default setting of 20 A (range is 0 A to 350 A).

Use E2 to change D2 value.

This parameter allows starting the welding process at a lower initial amperage setting.

Use E1 to change D1 to FI−A.

D2 value is default setting of 20 A (range is 0 A to 350 A).

Use E2 to change D2 value.

This parameter allows finishing the welding process at a lower final amperage setting.

Setting Postflow (only in MENU FULL)

Select MENU FULL on D1 and D2 (see Section 4-9).

Use E1 to change D1 to POSG.

D2 value is default setting of 0.1 second (range is 0.0 seconds to 10.0 seconds).

Use E2 to change D2 value.

Setting Cooler Status (only in MENU FULL)

.To prevent damage to water-cooled

torch components, be sure that cool- ant is turned on.

Select MENU FULL on D1 and D2 (see Section 4-9).

Use E1 to change D1 to W−UN.

D2 value is default setting of ON.

Use E2 to change D2 value to OFF, if appli- cable.

OM-224 043 Page 23

Image 27
Contents Xmsr From Miller to You Table of Contents Declaration of Conformity for European Community CE Products Symbol Usage Marks a special safety messageArc Welding Hazards Magnetic Fields can affect pacemakers ARC Rays can burn eyes and skinFire or Explosion hazard California Proposition 65 WarningsPrincipal Safety Standards EMF InformationAbout Pacemakers Manufacturer’s Warning Label Definitions − Definitions60 s 100 h. std Manufacturer’s Rating Labels Symbols And Definitions I1maxI1eff − Installation SpecificationsDuty Cycle And Overheating Volt-Ampere Curves Remove wire spool Turntable ScrewLocation Dimensions and WeightMovement Do not move or operate unit where it could tip Selecting a Location120 m Weld Output Terminals And Selecting Cable SizesRemote 7 Receptacle Information TIG And Stick Only ARC Welding can cause Electromagnetic InterferenceFilling Coolant Tank Circuit Breakers= GND/PE Electrical Service GuideConnecting Input Power 50/60 Hz Three PhaseFront Panel Controls − OperationWelding Process Selection Switching On the Unit and Recalling Factory ParametersBe aware that the wire type selection is Gas Selection in Synergic MIG or Synergic Pulsed MIG Welding Trigger Mode Selection TIG and Stick OnlySetting Menu Type TIG and Stick only Setup Push Button And Advanced Programming Selecting Manual MIG Welding During Setting Setting Cooler Status Preparing Unit For MIG WeldingSetting Cooler Status see Section Selecting Synergic MIG WeldingDuring Synergic MIG Welding Selecting Synergic Pulsed MIG Welding Preparing Unit For TIG Welding Setting Initial And Final Amperage only in Menu FullSetting Postflow only in Menu Full Setting Cooler Status only in Menu FullPreparing Unit For Stick Welding TIG Lift-Arc WeldingMonths − Maintenance & TroubleshootingDo not remove case when blowing out inside of unit Blowing Out Inside Of UnitHelp Displays Troubleshooting Software problemsIs displayed OM-224 043 − Electrical Diagram Unit Outer Assembly − Parts ListDia Part Description Quantity Mkgs Unit Main Assembly CR5,6,R1 Page Effective January 1 ITW Welding Products Italy S.r.l. Via Privata Iseo, 6/E Owner’s Record