Miller Electric XMS 4000 manual Volt-Ampere Curves, Remove wire spool Turntable Screw

Page 14

3-3. Volt-Ampere Curves

Volt-ampere curves show minimum and maximum voltage and amper- age output capabilities of unit. Curves of other settings fall be- tween curves shown.

A. CC Mode

B. CV Mode

 

ARC CONTROL

va_curve1 4/95 − SA-178 652 / SA-178 653

3-4. Installing Turntable for Wire Feeder on Power Source (Optional)

1

2

YTurn off welding power source and disconnect input power before proceeding.

Remove wire spool.

1Turntable

2Screw

Remove the 4 screws and the plas- tic cap on the power source upper cover and keep them for future use.

Insert the turntable in the upper hole and secure with 4 screws. Be sure screws are tight.

If desired, install the wire feeder on the turntable using the hole in the bottom of the feeder.

OM-224 043 Page 10

Image 14
Contents Xmsr From Miller to You Table of Contents Declaration of Conformity for European Community CE Products Arc Welding Hazards Symbol UsageMarks a special safety message ARC Rays can burn eyes and skin Magnetic Fields can affect pacemakersCalifornia Proposition 65 Warnings Fire or Explosion hazardAbout Pacemakers Principal Safety StandardsEMF Information − Definitions Manufacturer’s Warning Label Definitions60 s 100 h. std I1eff Manufacturer’s Rating Labels Symbols And DefinitionsI1max Duty Cycle And Overheating − InstallationSpecifications Remove wire spool Turntable Screw Volt-Ampere CurvesSelecting a Location Dimensions and WeightMovement Do not move or operate unit where it could tip LocationARC Welding can cause Electromagnetic Interference Weld Output Terminals And Selecting Cable SizesRemote 7 Receptacle Information TIG And Stick Only 120 mCircuit Breakers Filling Coolant Tank50/60 Hz Three Phase Electrical Service GuideConnecting Input Power = GND/PE− Operation Front Panel ControlsSwitching On the Unit and Recalling Factory Parameters Welding Process SelectionBe aware that the wire type selection is Trigger Mode Selection TIG and Stick Only Gas Selection in Synergic MIG or Synergic Pulsed MIG WeldingSetup Push Button And Advanced Programming Setting Menu Type TIG and Stick onlyPreparing Unit For MIG Welding During SettingSetting Cooler Status Selecting Manual MIG WeldingDuring Synergic MIG Welding Setting Cooler Status see SectionSelecting Synergic MIG Welding Selecting Synergic Pulsed MIG Welding Setting Cooler Status only in Menu Full Setting Initial And Final Amperage only in Menu FullSetting Postflow only in Menu Full Preparing Unit For TIG WeldingTIG Lift-Arc Welding Preparing Unit For Stick Welding− Maintenance & Troubleshooting MonthsHelp Displays Do not remove case when blowing out inside of unitBlowing Out Inside Of Unit Is displayed TroubleshootingSoftware problems OM-224 043 − Electrical Diagram − Parts List Unit Outer AssemblyDia Part Description Quantity Mkgs Unit Main Assembly CR5,6,R1 Page Effective January 1 Owner’s Record ITW Welding Products Italy S.r.l. Via Privata Iseo, 6/E