Honeywell W7750A specifications T7770 and T7560 Wall Modules, Honeywell Logo T7770D1018

Page 46

EXCEL 10 W7750A,B,C CONSTANT VOLUME AHU CONTROLLER

Table 11. Excel 10 W7750 Controller Ordering Information.

 

 

 

Part Number

Product Description

Comments

 

 

 

 

Excel 10 W7750 Controllers:

 

 

 

 

W7750A2005

Constant Volume AHU Controller (W7750A)

Three Analog Inputs, Three Digital Inputs and

 

 

Six 24 Vac Relay Outputs

 

 

 

W7750B2011

Constant Volume AHU Controller (W7750B)

Six Analog Inputs, Five Digital Inputs and Eight

 

 

(High-side Low-side switchable)Triac Outputs

 

 

 

W7750C2001

Constant Volume AHU Controller (W7750C)

Six Analog Inputs, Five Digital Inputs, Five Triac

 

 

Outputs and Three Analog Outputs

 

 

 

 

T7770 and T7560 Wall Modules:

 

 

 

 

T7770A1006

Sensor with Honeywell Logo

Used with Excel 5000 and Excel 10 Controllers

 

 

 

T7770A1014

Sensor with No Logo

Used with Excel 5000 and Excel 10 Controllers

 

 

 

T7770A2004

Sensor, LONWORKS Jack and Honeywell Logo

Used with Excel 5000 and Excel 10 Controllers

 

 

 

T7770A2012

Sensor with LONWORKS Jack and No Logo

Used with Excel 5000 and Excel 10 Controllers

 

 

 

T7770B1004

Sensor with Setpoint and LONWORKS Jack,

Degrees F Absolute

 

Honeywell Logo

 

 

 

 

T7770B1046

Sensor with Setpoint and LONWORKS Jack,

Relative Setpoint

 

Honeywell Logo

 

 

 

 

T7770B1012

Sensor with Setpoint and LONWORKS Jack, No

Degrees F Absolute

 

Logo

 

 

 

 

T7770B1020

Sensor with Setpoint and LONWORKS Jack,

Degrees C Absolute

 

Honeywell Logo

 

 

 

 

T7770B1053

Sensor with Setpoint and LONWORKS Jack, No

Relative Setpoint

 

Logo

 

 

 

 

T7770B1038

Sensor with Setpoint and LONWORKS Jack, No

Degrees C Absolute

 

Logo

 

 

 

 

T7770C1002

Sensor with Setpoint, Bypass/LED and

Degrees F Absolute

 

LONWORKS Jack, Honeywell Logo

 

 

 

 

T7770C1044

Sensor with Setpoint, Bypass/LED and

Relative Setpoint

 

LONWORKS Jack, Honeywell Logo

 

 

 

 

T7770C1010

Sensor with Setpoint, Bypass/LED and

Degrees F Absolute

 

LONWORKS Jack, No Logo

 

 

 

 

T7770C1028

Sensor with Setpoint, Bypass/LED and

Degrees C Absolute

 

LONWORKS Jack, Honeywell Logo

 

 

 

 

T7770C1051

Sensor with Setpoint, Bypass/LED and

Relative Setpoint

 

LONWORKS Jack, No Logo

 

 

 

 

T7770C1036

Sensor with Setpoint, Bypass/LED and

Degrees C Absolute

 

LONWORKS Jack, No Logo

 

 

 

 

T7770D1000

Sensor with Bypass/LED and LONWORKS Jack,

Degrees F Absolute

 

Honeywell Logo

 

 

 

 

T7770D1018

Sensor with Bypass/LED and LONWORKS Jack,

Degrees C Absolute

 

No Logo

 

 

 

 

T7560A1018

Digital Wall Module with Sensor, Setpoint and

 

 

Bypass/LCD, Honeywell Logo

 

 

 

 

T7560A1016

Digital Wall Module with Sensor, Setpoint,

 

 

Bypass/LCD and Humidity, Honeywell Logo

 

 

 

 

 

Sensors:

 

 

 

 

C7770A1006

Air Temperature Sensor. 20 Kohm NTC

Duct-mounted sensor that functions as a

 

nonlinearized

primary and/or secondary sensor.

 

 

 

C7031J1050

Averaging Discharge/Return Air Temperature

Duct element cord length 12 ft. (3.7m).

 

Sensor. 20 Kohm NTC

 

 

 

 

C7031B1033

Discharge Air or Hot Water Temperature

Use 112622AA Immersion Well.

 

Sensor. 20 Kohm NTC

 

 

 

 

74-2958— 1

46

Image 46
Contents Excel Appendices General Considerations W7750 Controllers72-2958 List of Figures 74-2958Setpoint ramping parameters with ramp rate calculation 74-2958List of Tables Description of Devices Typical system overviewControl Application Control ProvidedApplicable Literature Products CoveredOrganization of Manual Form No TitleProduct Names Agency ListingsAbbreviations and Definitions Construction ControllersW7750A DI-1Power Performance SpecificationsSpecial Note for the W7750B,C Unit CPU Specified Space Temperature Sensing RangeMemory Capacity Excel 10 W7750C Constant Volume AHU Controller Jack DIN rail adapters Lonmark Functional ProfileInputs/Outputs Analog InputsTriac Outputs on the W7750B,C Models only Digital InputsDigital Outputs T7770A1006 Wall ModulesDuct Sensor T7770CT7560A,B construction in in. mm Configurations GeneralConfiguration Options Summary For W7750A,B,C Controllers Heat Pump Control Allowable Heating and Cooling Equipment ConfigurationsStaged HEATING/COOLING Control Modulating HEATING/COOLING ControlEconomizer Control Pneumatic Actuator ControlWall Module Options Occupancy SensorWindow Open/Closed Digital Input MIXED-OUTPUT-TYPE ControlIndoor Air Quality IAQ Override Modes of OperationDirty Filter Monitor Smoke ControlNot OFF ModeDisabled AssignedDetermine Other Bus Devices Required OverviewPlan the System Step No DescriptionLay Out Communications and Power Wiring Lonworks Bus LayoutExcel VAV Cvahu Power Budget Calculation Example Power WiringDeviceVA Information Obtained from ML7984B PWM Valve Actuator VA Ratings For Transformer Sizing Device DescriptionML6161A/B Damper Actuator, 35 lb-in R8242A Contactor Line LossPower wiring details for one Excel 10 per Transformer Nema class 2 transformer voltage output limitsPrepare Wiring Diagrams General ConsiderationsW7750 Controllers Factory Default Digital Outputs Terminal Terminal Number DescriptionConstant Volume AHU Controller ML6161 Floating Actuator COM CCW Load Controller Power Heat Wall Economizer Damper PWM Actuator Power Signal W7750C Constant Lonworks Bus Termination Module Pneumatic transducer to W7750B,C Shown, see triangle noteBrown Orange Lonworks Bus termination wiring options Order EquipmentHoneywell Logo T7770D1018 T7770 and T7560 Wall ModulesSensor with Bypass/LED and Lonworks Jack Accessories Accessories SensorsEchelon Based Components and Parts Troubleshooting Excel 10 Controllers and Wall Modules Configure ControllersTroubleshooting CablingExcel 10 Alarms AlarmsResistance Value ohms Broadcasting the Service Message W7750 Controller Status LEDT7770C,D Wall Module Bypass Pushbutton and Override LED Appendix A. Using E-Vision to Commission a W7750 ControllerSetting the Pid Parameters Sensor CalibrationAppendix B. Sequences of Operation Common Operations Economizer Room Temperature Sensor RmTempHeating IAQ OptionSetpoint Limits LoSetptLim and HiSetptLim Bypass Mode StatusOvrd and StatusLedRemote Setpoint RmtStptPot BypassTimeNot Assigned Continuous Unoccupied ModeOccupancy Mode and Manual Override Arbitration Bypass OccupiedSchedule Master SchedMaster Recovery Ramping for Heat Pump SystemsTime Clock OccTimeClock Setpoint RampingFAN Operation Window Sensor StatusWndwSmoke Control Demand Limit Control DLCSee for a diagram of a typical W7750 Unit Temperature Control OperationsDirty Filter Monitor TWO Stages Staged Cooling ControlONE Stage Three StagesPulse Width Modulating PWM Control Cascade Control of Modulating COOLING/HEATINGSeries 60 Modulating Control Outdoor AIR Lockout of HEATING/COOLINGFreeze Stat Economizer ENABLE/DISABLE ControlIndoor AIR Quality IAQ Override Discharge AIR LOW Limit ControlEnergy Management Points Address Input Output Points AddressControl Parameters Address Status Points AddressMappable User Addresses and Table Number CO2 Concentration Relative TemperatureAir Flow EnthalpyValid states and the corresponding Application reset therefore, these points canPlaced in manual mode through a menu Enumerated values are shownNvName Field Name DefaultInput/Output Points Comments255 NciIoSelect DigitalIn2 NciIoSelect DigitalIn1Occsensor Shcedmasterin Occsensor UnuseddiCOOLSTAGE3 COOLSTAGE1COOLSTAGE2 COOLSTAGE4Sixtyfifty SiinvalidFalse PPM SiinvalidTrue StatusDI3 NvoIO UbDigitalIn EconEnSw NvoIO EconEnableInPosition when poor indoor air quality is detected OccSensr NvoIODefault Comments NvNameControl Parameters MinClRamp NciAux1SetPt UbMinClRampS0 Degrees F/Hr OdEnthalpyEnableMaxClRamp NciAux1SetPt UbMaxClRampS0 Degrees F/Hr MaxClRamp, OdTempMaxClRamp,PPM Gain for the cooling control loop Discharge air temperature cascade control loopGainCoolProp NciAux2SetPt UbKpCoolS2 Degrees F Degrees C GainHeatProp NciAux2SetPt UbKpHeatS2 Degrees F Degrees CEnergy Management Points Auxiliary functions. nviFree1 controls the FREE1OUT Refer to WSHPEnable.valueNviFree1 Value Network variable input failsRefer to nviTimeClk.value NviTimeClk ValueDestTimeClk NviTimeClk State 255 SrcTimeClkCt NvoTimeClk ValueStatus Points Bit Offset = FrostProtectAlrm Alarmbit1Bit Offset = SensorFailAlrm Bit Offset = InvalidSetPtAlrmSmokealarm NoalarmNodedisabled UpdateallfieldsHeat DisabledmodeStartupwait CoolNciAux1SetPts.ubOdEnthalpyEnableS2 StatusEconEn NvoData1 EconEnableAir flow switch is configured StatusManOcc NvoData1 NetManOccCoolStgsOn NvoData1 CoolStagesOn HeatStgsOn NvoData1 HeatStagesOnAuxiliary heating stages are turned on For both heating or coolingController mode is switched to Freezeprotect Is 1, the algorithm controls as per the settings foundNciConfig.SmokeControl MonitorSw NvoData1 MonSwitchSpacetempfield BypasstimerfieldTempcontrolptfield DischargetempfieldUbinvalid NvoError Errorbit0 StatusError NvoError Errorbit0SpaceTempError Bit Offset = Temperature SetPtError NvoError Errorbit0Are disabled as if the sensor was not configured NvoError Errorbit1Bit Offset = RtnEnthalpyError NvoError Errorbit1 Bit Offset = SpaceCO2Error NvoError Errorbit1Bit Offset = NvTodEventError NvoError Errorbit3 Bit Offset = NvWindowError NvoError Errorbit2Bit Offset = NvDlcShedError NvoError Errorbit2 Bit Offset = NvByPassError NvoError Errorbit3Cfgnul CfglocalCfgexternal Calibration PointsConfiguration Parameters False True CascCntrl NciConfig CascadeControl DisMinHtTime NciConfig DisableHeatMinTimeDisMinClTime NciConfig DisableCoolMinTime UseRaTempCtl NciConfigNone Normal Last NETOffset Absolutemiddle BypassonlyLonmark /Open System Points Hvacmrngwrmup Hvacprecool Hvaccool Hvacnightpurge Hvacnul HvacautoHvacheat HvacoffSNVTtempp 14 to 74-2958 100DestRmTemp NviSpaceTemp Degrees F SrcRmTemp NvoSpaceTemp Degrees FHvacmrngwrmup Hvacauto HvacnulHvactest Alarmnotifydisabled 255 Not configured 74-2958 NvoStatus Electricalfault103 NvoStatus Inalarm NvoStatus UnabletomeasureSwon SrcEconEnable NvoEcon State On other nodes. If the economizer function is configured byCorresponding economizer function is not enabled because SrcEconEnCt NvoEcon ValueDirect Access And Special Points OFF Data Share Points = including mapped points and others for Approximate Memory Size Estimating Procedure=using One-to-Many and not using points Mapped points = number of mapped points per ExcelSensor Type Sensor Resistance Versus Temperature Resistance OhmsResistance Sensors Sensor UseT7770B,C 10K ohm setpoint potentiometer Relative Offset Setpoint TemperatureDirect Setpoint Temperature Above and Below Setpoint Resistance OhmsSensor Voltage Versus Humidity Humidity Percentage Voltage/Current SensorsSensor Voltage Versus Humidity Relative Humidity Percentage Sensor Current Versus Enthalpy volts Enthalpy mA 113 74-295874-2958 114 T7242 or equivalentMAmAmAmA AmA mA mA Sensor Voltage Versus Input Voltage To A/D Voltage to A/D Inw Sensor Voltage Vdc Versus Pressure InwPressure Inw kPa Sensor Voltage Vdc 50.0.13