1800129688 GV8800 E0 A11_110x154 25/04/13 11:29 Page42
As steam is very hot : never attempt to remove creases from a garment while it is being worn, always hang |
| |
garments on a coat hanger. |
| |
• Holding the iron in a vertical position, tilted slightly forwards, press repeatedly on the steam control button | EN | |
(underneath the iron handle) moving the iron from top to bottom – fig.10. | ||
|
Refilling the water tank
•When the “tank empty” red warning light flashes – fig.9, it means that you have no more steam. The water tank is empty.
•Remove the water tank and pull horizontally. Fill it up without exceeding the MAX level – fig.5.
•Replace it fully into its housing until there is a click – fig.6.
•Press the “OK / RESTART” (depending on model) button -
Catalysis Autoclean Soleplate (depending on model)
•The iron of your steam generator comes with a
•Its unique coating makes it possible to eliminate all the impurities arising from normal usage.
•We recommend you always place your iron on its base or on the iron rest plate in order to protect its
Maintenance and cleaning
Cleaning your generator
• Do not use detergent or descaling products for cleaning the soleplate | Before cleaning, | |
• Never hold the iron or the base unit under the tap. | ensure that your | |
• Cleaning the soleplate: The iron of your steam generator comes with a | steam generator is | |
soleplate which functions by catalysis. Its unique coating actively allows it to continually | unplugged and that | |
eliminate all the impurities which are generated every day when the appliance is in normal | the soleplate and | |
the iron rest have | ||
use. Nevertheless, using your iron at an unsuitable temperature can leave marks which will | ||
cooled down. | ||
need to be cleaned manually. In this case we advise you to use a soft damp cloth on the | ||
| ||
soleplate whilst it is still warm so as not to damage the coating. |
| |
• Clean the plastic parts of the appliance occasionally with a soft cloth. |
|
Descaling your generator easily :
Do not use any descaling substances (vinegar, industrial descaling products, etc.) when rinsing the
For longer generator life, and to avoid scale emissions, your generator is equipped with a
Operation:
•An orange
Caution: this operation must not be performed until the generator has been unplugged for at least two hours and has completely cooled down. When performing this operation, the generator should be placed near a sink as water may flow out of the tank when it is opened.
•Once the generator has cooled down completely, remove the
•Unscrew the
•To clean the collector properly, just rinse it under running water to remove the scale it contains - fig.15.
•Put the collector back into its housing and screw it in completely to keep it watertight - fig.16.
•Refit the scale collector cover.
42