HP Performance Optimized Data Center (POD) 240a manual Power distribution electrical busway system

Page 28

WARNING: To avoid the risk of personal injury or loss of life, all personnel must comply with electrical warning labels when operating and maintaining the electrical panels and systems of the HP POD 240e NA.

For the external electrical power component locations, see "Electrical power component identification (on page 13)."

Power distribution: electrical busway system

Each IT section of the HP POD 240e NA is protected by an electrical circuit breaker panel located on the end of the HP POD 240e NA.

End view shown

The following specifications are for each IT section electrical circuit breaker panel.

Feature

Specification

 

 

Number of busways

8

Frequency

60 Hz

Amps (per busway)

200A

Voltage (per busway)

415V, wye

Grounding

Copper

Busway conductors

3-phase + neutral + equipment ground

Power distribution: Adiabatic system

The Adiabatic units are powered and protected by an electrical circuit breaker panel located on the end of the HP POD 240e NA. Within each AHU electrical cabinet, there are two panels that provide power to the Adiabatic units.

Power, electrical, and controls 28

Image 28
Contents Abstract Part Number November EditionPage Contents HP POD 240e NA optional components Power feeder pull boxes Air filter sensorRegulatory compliance notices Before you contact HP HP contact informationOperator safety Component safetyOverview Before you beginFire detection Preventative maintenanceEnvironmental considerations Component identification Structural component identificationParts and part number identification Component DescriptionLife safety component identification Exit sign locationsComponent identification Component identification End view shown Component Description Electrical power component identificationMain breaker locations Reminds you that the electrical panels must only be End view shown Callout Electrical safety label Description Electrical power disconnect map label locationControl cabinet component identification UPSSecurity component identification IT section B control cabinet Component DescriptionRacks Top view shown Component DescriptionLife safety overview Life safety systemsEPO system ECS touchscreen and EPO indicators Battery backup during an EPO event Component Indicator color DescriptionEPO modes EPO accidental activationVesda air sampling smoke detection system Fire detection systemManual fire pulls Fire alarm indicators Fire alarm panelFire detection sequence of operations Emergency egress Power, electrical, and controls Power safetySite electrical system Grounding and bondingCapacities Lightning protectionPower feeders Electrical panel labelsPower distribution electrical busway system Power distribution Adiabatic systemEnd view shown Feature Specification Wire color codePanel schedules Wire color Description Electrical buswaysPage Rack power Drop boxesFeature Specification LightingEnvironmental control system Using the ECSEnvironmental control system overview Components of the ECS Facility connections to the ECSSatellite control boxes Connecting to the ECS through the demarcation box Connecting to the ECS through connection portalsManaging the ECS from the HP POD 240e NA Configuring the ECS Environmental control system Logging in remotely to the ECS Locating the ECS IP address Click ConnectPassword protected Navigating the ECS interfaceLogging in to the ECS touchscreen ViewTop screen Callout Icon name DescriptionCA RH AD detail screen Information displayed DescriptionAisle in relation to the external ambient Charts screen AD detail screen displays the following alarm conditionsAlarm displayed Description Operation displayed DescriptionPsychrometric chart Alarms chart Electrical Cabinets screenControls Network screen Alarms screen Stats screen Indicates the cold aisle combination temperature Configure Control settingsHMI settings Setting the Min and Max temperature and RH setpoints Setting the Min and Max range for alarmsManaging the ECS system US Customary o MetricSetting the IP address Setting the offset alarmForcing an alarm Temperature and pressure sensors Maintaining the ECS parametersCallout Sensor Quantity per Description IT section Controlling the hot aisle fans Adiabatic unitsCallout Sensor Quantity per Description Hot aisle Overview AHU systemAdiabatic components AHU theory of operation Adiabatic mediaAHU system AHU system Static pressure control Networking IT networking and communicationsConnection portals Demarcation box Fire box Adding a phoneIT networking and communications Standard components Air filter sensorOptional components Power feeder pull boxesHP POD 240e NA optional components Specifications General specificationsRack specifications Features SpecificationsEnvironmental specifications Periodic maintenance MaintenancePreparing the Adiabatic units for winter Component Description Supply header gravity drain Adiabatic unit by unit blowdown Supply header blowdown Power up procedure Standard power up procedurePower up checklist Standard power up procedureCold weather power up procedure ElectricalCold weather power up checklist Cold weather operation Power down procedure Full power down procedureBefore you contact HP Contacting HPHP contact information Regulatory compliance notices Safety and NEC complianceHP POD 240e NA regulatory compliance Safety and regulatory compliance Warranty informationGlossary Power distribution unit North American Outside airProgrammable logic controller Performance-Optimized DatacenterPower usage efficiency Relative humidity Enclosure of sufficient size to enable entry of personnelUninterruptible power system Pounds per square inchDocumentation feedback Index Index Safety, component Safety, power connections Warranty Winterize, Hvac units 74 wire color code
Related manuals
Manual 8 pages 155 b Manual 26 pages 60.09 Kb Manual 39 pages 18.56 Kb