HP Performance Optimized Data Center (POD) 240a Optional components, Power feeder pull boxes

Page 71

Optional components

HP POD 240e NA optional components

There are several optional components available for the HP POD 240e NA, including but not limited to:

Controlled access

Power feeder pull boxes

For more information about optional components, see the Operations and Maintenance Manual for the HP Performance Optimized Datacenter 240e North America (Adiabatic).

Power feeder pull boxes

The HP POD 240e NA requires power feeder pull boxes for the electrical cabinets to prevent water from getting into the POD through the connection portals. The pull boxes can be customized to the facility and configuration of the power feeders.

For more information about the power feeder pull boxes, see the Operations and Maintenance Manual for the HP Performance Optimized Datacenter 240e North America (Adiabatic).

Optional components 71

Image 71
Contents Part Number November Edition AbstractPage Contents Air filter sensor HP POD 240e NA optional components Power feeder pull boxesBefore you contact HP HP contact information Regulatory compliance noticesBefore you begin Operator safetyComponent safety OverviewEnvironmental considerations Preventative maintenanceFire detection Structural component identification Component identificationComponent Description Parts and part number identificationExit sign locations Life safety component identificationComponent identification Component identification Main breaker locations Electrical power component identificationEnd view shown Component Description Reminds you that the electrical panels must only be Electrical power disconnect map label location End view shown Callout Electrical safety label DescriptionUPS Control cabinet component identificationIT section B control cabinet Component Description Security component identificationTop view shown Component Description RacksEPO system Life safety systemsLife safety overview ECS touchscreen and EPO indicators EPO accidental activation Battery backup during an EPO eventComponent Indicator color Description EPO modesManual fire pulls Fire detection systemVesda air sampling smoke detection system Fire detection sequence of operations Fire alarm panelFire alarm indicators Emergency egress Grounding and bonding Power, electrical, and controlsPower safety Site electrical systemLightning protection CapacitiesElectrical panel labels Power feedersPower distribution Adiabatic system Power distribution electrical busway systemPanel schedules Wire color codeEnd view shown Feature Specification Electrical busways Wire color DescriptionPage Drop boxes Rack powerLighting Feature SpecificationEnvironmental control system overview Using the ECSEnvironmental control system Satellite control boxes Facility connections to the ECSComponents of the ECS Connecting to the ECS through connection portals Connecting to the ECS through the demarcation boxManaging the ECS from the HP POD 240e NA Configuring the ECS Environmental control system Logging in remotely to the ECS Click Connect Locating the ECS IP addressNavigating the ECS interface Password protectedCallout Icon name Description Logging in to the ECS touchscreenView Top screenCA RH Information displayed Description AD detail screenAisle in relation to the external ambient Operation displayed Description Charts screenAD detail screen displays the following alarm conditions Alarm displayed DescriptionPsychrometric chart Electrical Cabinets screen Alarms chartControls Network screen Alarms screen Stats screen Indicates the cold aisle combination temperature Control settings ConfigureHMI settings US Customary o Metric Setting the Min and Max temperature and RH setpointsSetting the Min and Max range for alarms Managing the ECS systemForcing an alarm Setting the offset alarmSetting the IP address Maintaining the ECS parameters Temperature and pressure sensorsCallout Sensor Quantity per Description IT section Callout Sensor Quantity per Description Hot aisle Adiabatic unitsControlling the hot aisle fans Adiabatic components AHU systemOverview Adiabatic media AHU theory of operationAHU system AHU system Static pressure control Connection portals IT networking and communicationsNetworking Demarcation box Adding a phone Fire boxIT networking and communications Air filter sensor Standard componentsHP POD 240e NA optional components Power feeder pull boxesOptional components Features Specifications SpecificationsGeneral specifications Rack specificationsEnvironmental specifications Preparing the Adiabatic units for winter MaintenancePeriodic maintenance Component Description Supply header gravity drain Adiabatic unit by unit blowdown Supply header blowdown Standard power up procedure Power up procedureStandard power up procedure Power up checklistElectrical Cold weather power up procedureCold weather power up checklist Cold weather operation Full power down procedure Power down procedureHP contact information Contacting HPBefore you contact HP HP POD 240e NA regulatory compliance Safety and NEC complianceRegulatory compliance notices Warranty information Safety and regulatory complianceGlossary Performance-Optimized Datacenter Power distribution unitNorth American Outside air Programmable logic controllerPounds per square inch Power usage efficiency Relative humidityEnclosure of sufficient size to enable entry of personnel Uninterruptible power systemDocumentation feedback Index Index Warranty Winterize, Hvac units 74 wire color code Safety, component Safety, power connections