Speed vs. color code for PSC Motor:
Low = Orange
Med= Blue
High = Black
M. BLOWER CONTROLLER INFORMATION FOR PSC MOTOR
(Note: for ECM blower controller information see: ECM Operation Manual document #
TERMINAL DEFINITIONS & FIELD WIRING
Burner Harness Connector P2
Pin 1- Limit switch connector.
Pin 2- 120 VAC Line connection.
Pin 3- Burner pilot contact.
Pin 4&5- 120 VAC Neutral connections.
Pin 6- Burner pilot contact.
Pin 7&8- From oil primary control.
Pin 9- Limit Switch Input (LSI).
Field Wiring to Burner | Pilot (Tstat) | Neutral | Line | |||
|
|
|
| |||
Harness Wires |
| Yellow Wires | White | Red | ||
Beckett Connections |
| White | Black | |||
Riello Connections |
| N | L | |||
Thermostat / Humidistat connections |
|
|
| |||
“C” | Common / ground |
|
|
| ||
“W” | Thermostat call for heat |
|
| |||
“R” | 24 VAC to thermostat |
|
| |||
“G” | Thermostat call for fan |
|
| |||
“Y” | Thermostat call for cool |
|
| |||
“DEHUM” | Humidistat call for dehumidification (TXV systems ONLY) | |||||
Male quick connect terminals. |
|
|
| |||
120 VAC Hot |
|
|
| |||
120 VAC Neutral |
|
|
| |||
“EAC” | Electronic Air Cleaner (120 VAC) connection |
| ||||
“FAN” | Fan On Signal |
|
|
| ||
“X” | 24 VAC from transformer |
|
| |||
“C” | 24 VAC common from transformer |
|
| |||
“CC” | Compressor Contactor |
|
| |||
“CC_COM” | Compressor Contactor Common |
|
| |||
“LOW” | Continuous Blower Speed |
|
| |||
“HEAT” | Blower heat speed tap |
|
| |||
“COOL” | Blower cool speed tap |
|
|
31