HP 1GSa/s Digitizing Oscilloscope 16532A manual Test Record, Performance Test Interval

Page 27

HP 16532A - Performance Tests

3-1. Introduction

The procedures in this section test the oscilloscope module’s electrical performance using the specifications listed in Section I as the performance standards. All tests can be performed without access to the interior of the instrument. At the end of this section is a form that can be used as a record of performance test results.

3-2. Recommended Test Equipment

Equipment recommended for performance tests is listed in table 1-3. Any equipment that satisfies the critical specifications given in the table may be substituted for the recommended models.

3-3. Test Record

Results of performance tests may be tabulated on the Performance Test Record (table 3-1) at the end of the procedures. The test record lists all of the tested specifications and their acceptable limits.

SECTION III

Performance Tests

The results recorded on the test record may be used for comparison in periodic maintenance and troubleshooting or after repairs and adjustments have been made.

3-4. Performance Test Interval

Periodic performance verification of the

HP 16532A Oscilloscope Module is required at one-year intervals. The instrument’s performance should be verified after it has been serviced, or if improper operation is suspected. Calibration should be performed before any performance verification checks.

3-5. Performance Test Procedures

All performance tests should be performed at the environmental operating temperature of the instrument, after a 30-minute warmup period.

3-1

Image 27
Contents HP 16532A Safety Symbols Safety ConsiderationsContents Service CalibrationSection Replaceable Parts List of Tables Page Table of Contents Page Safety Requirements IntroductionModule Covered by This Manual Operating Characteristics Accessories SuppliedAccessories Available SpecificationsVertical dc Gain Accuracy4 ± 1.5% of full scale HP 16532A SpecificationsRise Time2 1.4 ns Waveform Record Length 8000 pointsHP 16532A Operating Characteristics Vertical at BNCTimebase Trigger Modes TriggeringDigitizer Trigger Level RangeDisplay Modes Waveform DisplayMeasurement Aids Operating Environment Setup AidsEquipment Critical Specifications Recommended Model USE Page Table of Contents Page Preparation for Use Power RequirementsInitial Inspection Safety Requirements Module InstallationProcedure Installation ConsiderationsEndplate Overlap Bottom Sequence Packaging Tagging for ServiceOperating Environment StorageTable of Contents Page Performance Test Procedures Test RecordPerformance Test Interval DC CAL Output Test AC CAL Output Test Specification Equipment Required Critical Specification Model/Part NumberInput Resistance Page Voltage Measurement Accuracy Voltage Measurement Accuracy Test Div Offset Supply Upper Limit Lower Limit Offset Accuracy Procedure Zero-Input OffsetDiv Offset Supply Min Max DC Input OffsetBandwidth V1MHz Time Measurement Accuracy Menu Selection Setting Trigger Sensitivity RUN Repetitive Performance Test Record Paragraph No Test Results Yes No Page Table of Contents Page Calibration Protection Switch Calibration IntervalMaintaining System Integrity Calibration Instrument WarmupLocation of the PROTECT/UNPROTECT Switch Setting the PROTECT/UNPROTECT Switch to UnprotectEquipment Required for Calibration Loading the Default Calibration FactorsCalibrate Delay of the Self Cal menu as follows Self Cal Menu CalibrationsCalibrate Vert Cal of the Self Cal menu as follows Calibrate the Logic Trigger of the Self Cal menu as follows Calibrate the Time Null of the Self Cal menu as followsExt Trig Null Calibration Connections Calibrate the Ext Trig Null of the Self Cal menu as followsSealing the Mainframe Setting the PROTECT/UNPROTECT Switch to ProtectTable of Contents Page Exchange Assemblies Replaceable Parts ListAbbreviations Ordering InformationDirect Mail Order System Reference Designator and Abbreviations Parts Identification Mfr Code Mfr Part Number Reference DesignatorHP Part Qty Number DescriptionPage Table of Contents Page Attenuator Theory of Operation Introduction Safety RequirementsModule Block Diagram and The- ory of Operation Main Assembly Theory of OperationHP 16532A Oscilloscope Block Diagram Page Self-Tests Self-Test Access ProcedureLoad Test System Screen Touch the Functional Tests field Functional Tests ScreenA/D Test Run Screen Exit Test System Screen Test Self-Test DescriptionsData Memory Test Timebase TestTroubleshooting Aids TroubleshootingVerifying the System Clock Page Troubleshooting E E T Troubleshooting Sheet1 6 5 3 2 a Troubleshooting E E T Troubleshooting E E T Troubleshooting E E T Troubleshooting E E T Oscilloscope Module Removal Procedure Oscilloscope Module Removal and Replacement12. Endplate Overlap Bottom Sequence Oscilloscope Module Replacement ProcedureTrigger Cable Removal Procedure Trigger Cable Removal and ReplacementAttenuator Removal and Replacement Trigger Cable Replacement ProcedureAttenuator Removal Procedure Attenuator Replacement Procedure Warranty CertificationAssistance