Omega Vehicle Security FPU5-MT-220, FPU5-MT-110 manual Stacking Two Pumps on One Side of the Motor

Page 22

Getting Started

3

 

 

5.Refer to Figure 3-4. With the pump and motor aligned, insert the mounting screws through the mounting holes in the pump, until they make contact with the threaded mounting holes in the face of the motor.

6.Tighten the screws fully with a 9/64 (M3.5) allen wrench.

3.1.3Stacking Two Pumps on One Side of the Motor

CAUTION

Perform ALL of the steps in Chapter 3 before turning the motor on.

FACE OF

MOTOR

FIRST

PUMP

SECOND

PUMP

Figure 3-5. Placing the Second Pump on Top of the First Pump

FACE OF

MOTOR

FIRST PUMP

SECOND

PUMP

FLAT HEAD

SCREWDRIVER

Figure 3-6. Aligning the Rotor Shaft of the Second Pump

LONG

MOUNTING

SCREWS

Figure 3-7. Securing Both Pumps to the Motor

1.Remove the safety cover if it is on the side of the motor you wish to use. Attach it to the other side.

2.Refer to Figure 3-1 through Figure 3-3. Perform Steps 1, 2 and 3 in Section 3.1.2 to put the first pump on the face of the motor.

3.Refer to Figure 3-1. Make sure the second pump is in the closed position.

4.Refer to Figure 3-5 and Figure 3-6. Place the blade of the flathead screwdriver in the groove of the Rotor Shaft of the second pump. Rotate the Rotor Shaft of the second pump until its back tab slips into the groove of the Rotor Shaft of the first pump.

5.Refer to Figure 3-7. With the pumps and motor aligned, insert the optional LONG mounting screws through the mounting holes in both pumps, until they make contact with the threaded mounting holes in the motor.

6.Tighten the long screws fully with a small flathead screwdriver.

3-3

Image 22
Contents User’s Guide Servicing North America Unpacking Instructions Table of Peristaltic Pump Motor Chapter Specifications Spare Parts and Accessories 10-1 Peristaltic Pump MotorPeristaltic Pump Motor Index RPMIndex III Introduction FeaturesDescription Introduction Front View Parts of the Pump MotorFront View Description FunctionLeft Side View Left Side ViewRight Side View Right Side ViewMembrane Keypad and Display Membrane Keypad DetailMembrane Keypad Details cont’d Flow Rate keyUP and Down Arrow Keys Scrolling Limits Rear ViewRear View Rear View cont’d Language ButtonParts of the Pump Motor Attaching the Pump Pump Motor Mounting Configurations Number of Pumps onGetting Started IntroductionAttaching a Single Pump Directly to the Motor Refer to Figures 3-1 throughStacking Two Pumps on One Side of the Motor Placing the Second Pump on Top of the First PumpTubing Life Selecting TubingLoading the Tubing See .2 to set the pumping direction Getting Started Stopped Display Mode Turning on the PowerUsing the ON/OFF Switch Introduction to the Two Display ModesRunning Display Mode Stopped vs. Running Display ModesOperating the Pump Motor Stopped Display ModeDisplaying Pump Messages in Five Different Languages English French Spanish German Italian Régler LA QTÉDefining the Direction of Pumping Selecting the Tubing Inner Diameter Left Pump Right PumpTube Inner Diameters English Metric Priming the Tubing Calibrating the TubingOperating the Pump Motor in the Stopped Display Mode Tips for Optimum Calibration Accuracy Measuring the Temperature of a Fluid Preparing for Pumping in a Specific ModeTotal Volume RPM Mode Running Display ModePumping in the RPM Mode Shows the range of the RPM numbers you can work with RPM Mode Cont’d Flow Rate Mode Pumping in the Flow Rate ModeShows the ranges allowed for the various tubing sizes Flow Rate Ranges cont’d Display Xxx mL/min Flow Rate Mode Flow Rate Mode Time Mode Pumping in the Time ModeTime Range Display Xxxxxx Time Mode Time Mode Total Volume Mode Block Diagram Pumping in the Total Volume ModePumping in the Total Volume Mode Total Volume RangeOperating the Pump Motor in the Running Display Mode Total Volume Mode Cont’d Other Pumping Options Preventing Tubing from Moving During Pump OperationAuxiliary Out Remote Monitor 500Ω LED Auxiliary In Remote Start/StopError Message Problem Troubleshooting GuideDisplay Error Messages SolutionError Message Running Display Mode and try to select the command againLocked Rotor? Overcurrent Press the Total Volume key Short Circuit? Error Message Other Pumping Problems Stopped Display Mode and refer to SectionProblem Solution Another pump, if necessary Troubleshooting Guide Technical Details Design SolutionMaintenance Theory of OperationTechnical Details Specifications Calibration AccuracyTubing Materials Average Flow RatesMotor SpeedAverage Tubing Life ⁄32 300 ⁄16 250 100 ML Per Revolution Specifications Spare Parts Spare Parts and AccessoriesAccessories Part Number DescriptionAccessories cont’d Peristatic Pump 10-4 WARRANTY/DISCLAIMER