Omega Vehicle Security FPU5-MT-220, FPU5-MT-110 manual Time Mode

Page 52

 

 

 

Table 6-3 (cont’d)

TIME MODE

 

KEY

 

DISPLAY

 

ACTION TAKEN

 

 

 

 

SHOWS

 

AND PROCEDURE

 

 

 

 

 

 

 

 

 

 

 

xx:xx:xx

 

Displays current TIME setting

 

 

TIME

 

 

 

 

 

 

 

1.

Press the TIME key. The display flashes the TIME setting you

 

 

 

 

 

 

 

 

 

selected just before starting the pump.

2.Use the UP and DOWN ARROW keys to enter the TIME setting you desire. As you use the UP and DOWN ARROW keys, the display changes accordingly. The SECONDS scroll,

 

 

 

 

 

 

 

When you reach 0 or 59 seconds, the minutes setting changes.

 

 

 

 

 

 

 

When you reach 0 or 59 minutes , the HOURS setting

 

 

 

 

 

 

 

changes. Refer to Figure 6-5.

 

 

 

 

 

 

 

NOTE: While the pump is running, you can not use the TIME key to

 

 

 

 

 

 

 

toggle from SECONDS to MINUTES TO HOURS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

xxx mL/min

Displays actual FLOW RATE

 

FLOW

 

 

 

 

 

RATE

 

 

 

or

 

 

 

 

 

 

 

Press the FLOW RATE key. The display flashes the calculated fluid

 

 

 

 

 

 

 

 

 

 

 

xxx L/min

 

 

 

 

 

 

flow rate (xxx mL/min or xxx L/min).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

xxx mL

Displays cumulative TOTAL VOLUME since start

 

 

 

TOTAL

 

 

 

 

 

 

or

 

 

 

 

VOLUME

 

 

Press the TOTAL VOLUME key. The display flashes the calculated

 

 

 

 

 

 

xxx Liters

 

 

 

 

 

 

 

 

 

 

 

 

volume of fluid dispensed since the pump started running (xxx mL

 

 

 

 

 

 

 

or xxx Liters).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TUBE ID=xxx

Displays current TUBE ID

 

TUBE ID

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press the TUBE ID key. If the red LED next to the CALIBRATE key

 

 

 

 

 

 

 

 

 

 

 

 

 

 

is not lit, the display flashes the current TUBE ID setting. If the red

 

 

 

 

 

 

 

LED next to the CALIBRATE key is lit, the display flashes the

 

 

 

 

 

 

 

message “CALIBRATED TUBE!”.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CALIBRATED!

Displays calibration state

 

 

 

CALIBRATE

 

 

 

 

 

 

or

 

 

 

 

 

 

 

1. Press the CALIBRATE key. If the red LED next to the

 

 

 

 

 

 

not calibrated

 

 

 

 

 

 

CALIBRATE key is not lit, the display shows “not calibrated”.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If the red LED next to the CALIBRATE key is lit, the display

 

 

 

 

 

 

 

shows “CALIBRATED!”.

 

 

 

 

 

 

 

To calibrate a tube:

2.Press the START/STOP key to stop the pump. The display returns to the STOPPED Display Mode. For detailed instruc- tions on “Calibrating a Tube”, refer to Section 5.5.

 and 

xx:xx:xx

NOTE: if you press the UP and DOWN ARROW keys, the display

shows the current TIME setting. This setting changes

 

 

 

 

accordingly as you use the UP and DOWN ARROW keys.

 

 

 

Language

 

NOTE: if you press the Language button, the display changes to

 

the next language in the sequence: English, French,

Button

 

 

Spanish, German, and Italian.

 

 

 

 

You will not notice this change unless the display

 

 

shows something other than time. It is easier to change

 

 

languages when you watch the display change.

6-15

Image 52
Contents User’s Guide Servicing North America Unpacking Instructions Table of Peristaltic Pump Motor Chapter Specifications Spare Parts and Accessories 10-1 Peristaltic Pump MotorPeristaltic Pump Motor Index RPMIndex III Introduction FeaturesDescription Introduction Parts of the Pump Motor Front ViewFront View Description FunctionLeft Side View Left Side ViewRight Side View Right Side ViewMembrane Keypad and Display Membrane Keypad DetailMembrane Keypad Details cont’d Flow Rate keyUP and Down Arrow Keys Scrolling Limits Rear ViewRear View Rear View cont’d Language ButtonParts of the Pump Motor Pump Motor Mounting Configurations Number of Pumps on Getting StartedAttaching the Pump IntroductionAttaching a Single Pump Directly to the Motor Refer to Figures 3-1 throughStacking Two Pumps on One Side of the Motor Placing the Second Pump on Top of the First PumpTubing Life Selecting TubingLoading the Tubing See .2 to set the pumping direction Getting Started Turning on the Power Using the ON/OFF SwitchStopped Display Mode Introduction to the Two Display ModesRunning Display Mode Stopped vs. Running Display ModesOperating the Pump Motor Stopped Display ModeDisplaying Pump Messages in Five Different Languages English French Spanish German Italian Régler LA QTÉDefining the Direction of Pumping Selecting the Tubing Inner Diameter Left Pump Right PumpTube Inner Diameters English Metric Priming the Tubing Calibrating the TubingOperating the Pump Motor in the Stopped Display Mode Tips for Optimum Calibration Accuracy Measuring the Temperature of a Fluid Preparing for Pumping in a Specific ModeTotal Volume RPM Mode Running Display ModePumping in the RPM Mode Shows the range of the RPM numbers you can work with RPM Mode Cont’d Flow Rate Mode Pumping in the Flow Rate ModeShows the ranges allowed for the various tubing sizes Flow Rate Ranges cont’d Display Xxx mL/min Flow Rate Mode Flow Rate Mode Time Mode Pumping in the Time ModeTime Range Display Xxxxxx Time Mode Time Mode Total Volume Mode Block Diagram Pumping in the Total Volume ModePumping in the Total Volume Mode Total Volume RangeOperating the Pump Motor in the Running Display Mode Total Volume Mode Cont’d Other Pumping Options Preventing Tubing from Moving During Pump OperationAuxiliary Out Remote Monitor 500Ω LED Auxiliary In Remote Start/StopTroubleshooting Guide Display Error MessagesError Message Problem SolutionError Message Running Display Mode and try to select the command againLocked Rotor? Overcurrent Press the Total Volume key Short Circuit? Error Message Other Pumping Problems Stopped Display Mode and refer to SectionProblem Solution Another pump, if necessary Troubleshooting Guide Design Solution MaintenanceTechnical Details Theory of OperationTechnical Details Specifications Calibration AccuracyAverage Flow Rates MotorTubing Materials SpeedAverage Tubing Life ⁄32 300 ⁄16 250 100 ML Per Revolution Specifications Spare Parts and Accessories AccessoriesSpare Parts Part Number DescriptionAccessories cont’d Peristatic Pump 10-4 WARRANTY/DISCLAIMER