WARRANTY/DISCLAIMER

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 25 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal two (2) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.

If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs.

OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.

CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.

RETURN REQUESTS/INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.

The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.

FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:

1.Purchase Order number under which the product was PURCHASED,

2.Model and serial number of the product under warranty, and

3.Repair instructions and/or specific problems relative to the product.

FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:

1. Purchase Or

Image 83
Contents User’s Guide Servicing North America Unpacking Instructions Table of Peristaltic Pump Motor Peristaltic Pump Motor Chapter Specifications Spare Parts and Accessories 10-1Peristaltic Pump Motor RPM IndexIndex III Description FeaturesIntroduction Introduction Description Function Parts of the Pump MotorFront View Front ViewLeft Side View Left Side ViewRight Side View Right Side ViewMembrane Keypad Detail Membrane Keypad and DisplayFlow Rate key Membrane Keypad Details cont’dRear View Rear ViewUP and Down Arrow Keys Scrolling Limits Language Button Rear View cont’dParts of the Pump Motor Introduction Pump Motor Mounting Configurations Number of Pumps onGetting Started Attaching the PumpRefer to Figures 3-1 through Attaching a Single Pump Directly to the MotorPlacing the Second Pump on Top of the First Pump Stacking Two Pumps on One Side of the MotorLoading the Tubing Selecting TubingTubing Life See .2 to set the pumping direction Getting Started Introduction to the Two Display Modes Turning on the PowerUsing the ON/OFF Switch Stopped Display ModeStopped vs. Running Display Modes Running Display ModeDisplaying Pump Messages in Five Different Languages Stopped Display ModeOperating the Pump Motor Régler LA QTÉ English French Spanish German ItalianDefining the Direction of Pumping Left Pump Right Pump Selecting the Tubing Inner DiameterTube Inner Diameters English Metric Calibrating the Tubing Priming the TubingOperating the Pump Motor in the Stopped Display Mode Tips for Optimum Calibration Accuracy Preparing for Pumping in a Specific Mode Measuring the Temperature of a FluidTotal Volume Pumping in the RPM Mode Running Display ModeRPM Mode Shows the range of the RPM numbers you can work with RPM Mode Cont’d Pumping in the Flow Rate Mode Flow Rate ModeShows the ranges allowed for the various tubing sizes Flow Rate Ranges cont’d Display Xxx mL/min Flow Rate Mode Flow Rate Mode Pumping in the Time Mode Time ModeTime Range Display Xxxxxx Time Mode Time Mode Block Diagram Pumping in the Total Volume Mode Total Volume ModeTotal Volume Range Pumping in the Total Volume ModeOperating the Pump Motor in the Running Display Mode Total Volume Mode Cont’d Auxiliary Out Remote Monitor Preventing Tubing from Moving During Pump OperationOther Pumping Options Auxiliary In Remote Start/Stop 500Ω LEDSolution Troubleshooting GuideDisplay Error Messages Error Message ProblemRunning Display Mode and try to select the command again Error MessageLocked Rotor? Overcurrent Press the Total Volume key Short Circuit? Error Message Stopped Display Mode and refer to Section Other Pumping ProblemsProblem Solution Another pump, if necessary Troubleshooting Guide Theory of Operation Design SolutionMaintenance Technical DetailsTechnical Details Calibration Accuracy SpecificationsSpeed Average Flow RatesMotor Tubing MaterialsAverage Tubing Life ⁄32 300 ⁄16 250 100 ML Per Revolution Specifications Part Number Description Spare Parts and AccessoriesAccessories Spare PartsAccessories cont’d Peristatic Pump 10-4 WARRANTY/DISCLAIMER