SunSource® Home Energy System

This Dave Lennox Signature® Collection heat pump is factory−equipped with components that make it SunSource® solar−ready. These units can be matched with solar modules and other optional equipment so that they can become part of a SunSource® Home Energy System.

Units can be upgraded for use with solar equipment at the time of installation or in the future.

Solar energy is first used to meet cooling/heating demands. When the outdoor unit is not operating, the system powers lighting, appliances and other electronic devices in the home. Any surplus power is sent back to the utility company for a possible credit (check with your local utility company for availability).

The SolarSynct package consists of the following components:

SLennox® Solar Subpanel installed in a Dave Lennox Signature® Collection air conditioner or heat pump unit.

SSolar modules (1 to 15 may be used to vary the amount of electricity generated).

SEnvoy Communications Gateway monitors solar power performance.

All components must be ordered separately. See the Lennox XP17 Engineering Handbook for SunSource® Home Energy System component ordering.

Wiring runs from the roof−mounted solar modules to the outdoor unit. From there, power travels to the home electrical service panel using the existing outdoor unit power wiring.

Page 53

XP17 SERIES

Image 53
Contents Heat Pumps Table of ContentsGeneral Side View Access View Unit Dimensions −− Inches mmModel Number Identification Base with Elongated LegsControl BOX Typical Unit Parts ArrangementShipping and Packing List Using Manifold Gauge SetOperating Service Valves Operating Ball Type Service Valve Operating Angle Type Service ValveTo Access Service Port Reinstall Stem Cap1DISCONNECT Power Recovering Refrigerant from Existing SystemRecovering Refrigerant 2CONNECT Manifold Gauge SETUnit Placement Placement, Slab Mounting and Stabilizing Unit Detail a Outside Unit PlacementRoof Mounting Removing and Installing PanelsStabilizing Unit on Uneven Surfaces Louvered Panel Removal Louvered Panel InstallationDetail C Detail D Detail aRefrigerant Line SET New or Replacement Line SetRefrigerant Line SET Alling Horizontal Runs Refrigerant Line SET From Vertical to HorizontalBrazing Connections 2CAP and Core Removal 1PIPING Panel Removal and Preparing Line SETFlow Nitrogen Wrap Service ValvesBraze Line SET 7PREPARATION for Next StepFlushing Line Set and Indoor Coil Flushing Line Set and Indoor CoilIndoor Expansion Valve Installation Installing Indoor Expansion ValveSensing Bulb Installation Equalizer Line InstallationLeak Test Leak Test Line Set and Indoor CoilS S S S Evacuating Line Set and Indoor Coil2INSTALL Thermostat Size Circuit and Install DisconnectElectrical 24VAC Transformer4ROUTE High Voltage and Ground Wires 3A. Route Control Wires TingRoute Control Wires Ting Typical XP17 Wiring Heat Pump Control AGE Heat Pump Control A175 Jumpers and TerminalsHeat Pump Control A175 Jumper and Terminal Descriptions Flat metal jumper Field Control WiringFurnace Control Servicing Units Delivered Void of Charge Connections for Testing and ChargingUnit Start−Up System RefrigerantHeating Mode Indoor Airflow Check Cooling Mode Indoor Airflow CheckAdding or Removing Refrigerant Airflowindoor CoilSubcooling Charging Method Using HFC−410A Weigh In MethodAir Handler / Coil Match ups and Targeted Subcooling Values Psig Operating and Temperature PressuresDefrost System System OperationsUnit Sensors Resistor Location Sensor Temperature / Resistance RangeYES Defrost Calibration Sequence of OperationsS S Test Pin E33 FunctionsOr below Low Pressure S87 Switch OperationHigh Pressure Switch S4 Sequence of Operation Input Fault or Miswire Degrees Resistance Fahrenheit 136.3 2680 DS11 and DS14 ATUS, Fault Lockout LED Codes System Status, Fault and Lockout LED CodesResetting Fault and Lockout LED Codes DS15 and DS13 Ault Lockout LED CodesModerate Device Alert Status225ºF 107ºC Lockout Vice removed or Clears after Troubleshooting Field Configuration and TestingFAN Motor B4 Test Procedure FAN Motor Control A177 OPERATION,Fan Motor Control Stage LED Indicator Codes Fan Motor Control Error/Fault LED CodesFan Motor Control RPM, LED Code and DC Voltage Output Fan Motor Control Flash and Pause DurationsTOP Grille Adjustment TOP Grille or FAN Motor Mount Adjustment for FAN ClearanceFAN Motor Position Adjustment Demand BeginsFAN Motor Control A177 PULSE−WIDTH Modulation PWM Testing for External Power to Fan Motor Control Start StripTerminal FinishSnow Guard Top Cover MaintenanceHomeowner SunSource Home Energy System Cooling Mode XP17 Start−Up and Performance ChecklistHeating Mode START−UP Checks