Heat Pump Control | icomfort |
|
|
|
|
|
|
| ||
LEDs |
|
|
|
|
|
|
|
| ||
| Touch® |
|
| Possible |
|
|
|
| ||
|
|
|
| Condition | Solution | Clearing Status | ||||
DS15 |
| DS13 | Thermostat |
| Cause(s) | |||||
|
|
|
|
|
|
| ||||
Yellow |
| Red | Display |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| Compressor has | 1 | Run capacitor has failed. |
| |
|
|
|
|
|
| a locked out due | 2 | Low line voltage (contact utility if voltage at discon- | Clears after | |
4 flashes |
|
| Critical Alert |
|
| to run capacitor |
| nect is low). | power reset or | |
| Off |
| Locked rotor | short, bearings |
| four normal | ||||
|
|
|
|
| ||||||
then pause |
| Code 404 |
|
| S | Check wiring connections | ||||
|
|
|
| are seized, |
| compressor | ||||
|
|
|
|
|
| 3 | Excessive liquid refrigerant in the compressor. | |||
|
|
|
|
|
| excessive liquid | cycles. | |||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| refrigerant. | 4 | Compressor bearings are seized. |
| |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| 1 | Outdoor unit power disconnect is open. |
| |
|
|
|
|
|
|
| 2 | Unit circuit breaker or fuse(s) is open. |
| |
|
|
|
|
|
|
| 3 | Unit contactor has failed to close. |
| |
|
|
|
|
|
|
|
| S | Check compressor contactor wiring and |
|
|
|
|
|
|
|
|
|
| connectors |
|
|
|
|
|
|
|
|
| S | Check for compressor contactor failure |
|
|
|
|
|
|
|
|
|
| (burned, pitted or open) |
|
|
|
|
|
|
| Compressor has |
| S Check wiring and connectors between supply | Clears after one | |
|
|
|
|
|
| an open circuit |
| |||
|
|
|
|
|
|
|
| and compressor | normal com- | |
5 flashes |
|
| Critical Alert |
|
| due to power dis- |
|
| ||
| Off |
| Open circuit |
| S | Check for low pilot voltage at compressor | pressor run | |||
then pause |
| Code 405 |
| connection, fuse |
| |||||
|
|
|
|
|
| contactor coil | cycle or power | |||
|
|
|
|
|
| is open or other |
|
| ||
|
|
|
|
|
| 4 |
|
| reset. | |
|
|
|
|
|
| similar conditions. | High pressure switch is open and requires manual | |||
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
| reset. |
| |
|
|
|
|
|
|
| 5 | Open circuit in compressor supply wiring or |
| |
|
|
|
|
|
|
|
| connections. |
| |
|
|
|
|
|
|
| 6 | Unusually long compressor protector reset time |
| |
|
|
|
|
|
|
|
| due to extreme ambient temperature. |
| |
|
|
|
|
|
|
| 7 | Compressor windings are damaged. |
| |
|
|
|
|
|
|
|
| S Check compressor motor winding resistance |
| |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| 1 | Run capacitor has failed. |
| |
|
|
|
|
|
|
| 2 | Open circuit in compressor start wiring or | Clears when | |
6 flashes |
|
| Critical Alert |
| Open start | Current not |
| connections. | amperage is de- | |
|
|
|
|
|
| tected in RUN | ||||
| Off |
| sensed by Start |
| S Check wiring and connectors between supply | |||||
then pause |
| Code 406 |
| circuit |
| and START | ||||
|
|
|
|
|
| transformer. |
|
| and the compressor S terminal | sensors, or after |
|
|
|
|
|
|
| 3 | Compressor start winding is damaged. | ||
|
|
|
|
|
|
| power reset. | |||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| S Check compressor motor winding resistance |
| |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| 1 | Open circuit in compressor start wiring or | Clears when | |
|
|
|
|
|
|
|
| connections. | ||
|
|
|
|
|
|
|
| amperage is de- | ||
|
|
|
|
|
| Current not |
|
|
| |
7 flashes |
|
| Critical Alert |
| Open run |
| S Check wiring and connectors between supply | tected in RUN | ||
| Off |
| sensed by run |
| ||||||
then pause |
| Code 407 |
| circuit |
|
| and the compressor R terminal | and START | ||
|
|
| transformer. |
|
| |||||
|
|
|
|
|
| 2 | Compressor start winding is damaged. | sensors, or after | ||
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
| S Check compressor motor winding resistance | power reset. | |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
|
| Clears after one |
8 flashes |
|
| Critical Alert |
| Welded | Compressor | Compressor contactor failed to open. | normal com- | ||
| Off |
| 2 | Thermostat demand signal not connected to mod- | pressor run | |||||
then pause |
| Code 408 |
| contactor | always runs | |||||
|
|
|
| ule. |
| cycle or after | ||||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| power reset. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 | Control circuit transformer is overloaded. | Clears after volt- | |
|
|
| Moderate/ |
|
|
| age is higher | |||
|
|
|
|
|
| 2 |
|
| ||
9 flashes |
|
|
| Secondary low | 24VAC is below | Low line voltage (contact utility if voltage at discon- | than 20VAC for | |||
| Off | Critical Alert3 |
| |||||||
then pause |
|
| voltage | 18VAC. |
| nect is low). | two seconds, or | |||
|
| Code 409 |
|
| ||||||
|
|
|
|
|
|
| S | Check wiring connections | after power re- | |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| set. | ||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
Fast simultaneous flashing of DS11, |
| OEM Mode | Factory test mode. |
|
|
|
| |||
DS13, DS14 and DS15 |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| ||
1. Pause duration is two (2) seconds. |
|
|
|
|
|
|
2. Fast flash duration is 1/2 second. Slow flash duration is one (1) second.
3. Initially a moderate status is displayed and is escalated to critical if alarm exists for more than 10 minutes.