Slant/Fin J-390 installation instructions 101112

Page 18

18

Jaguar Model J-390

 

 

 

12 Kohm

 

 

 

BOILER

L1

 

 

L2

 

 

DHW TANK

OUTDOOR

 

 

 

CIRCULATOR

HOT

 

NEUTRAL

GROUND

 

SENSER

 

 

 

 

 

 

 

 

 

 

 

THERMOSTAT

LOW WATER

DHW

 

 

120V

 

 

 

(IF USED)

(IF USED)

 

 

60HZ

 

 

 

 

 

 

CUT OFF

CIRCULATOR

 

 

 

 

"CALL FOR HEAT"

 

 

 

 

 

 

 

 

 

 

 

(IF USED,REMOVE

(IF USED)

 

 

1

 

 

 

24V ROOM THERMOSTAT

 

 

 

7-8 JUMPER)

 

 

 

 

 

 

 

OR ISOLATED CONTACT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 2

3 4

5 6 7 8

FIELD WIRING

H N H

N H N

 

 

 

 

 

TERMINALS

 

 

 

 

 

 

W W

 

 

 

R R

 

 

 

 

 

J2

 

 

 

 

 

 

 

 

 

 

W

 

W

 

 

 

 

 

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

 

 

 

 

 

 

 

 

 

 

Y

 

 

 

 

 

 

 

 

G

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BK

 

 

 

 

 

 

 

 

BL

 

 

 

 

W

 

 

 

W

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W

 

 

 

 

 

 

 

 

BK

W

BK

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BL

 

 

 

 

1

2 3

J6

POWER

 

 

4

 

 

 

 

 

 

 

 

ON/OFF

 

 

 

W

 

 

 

 

 

 

 

J9

 

SWITCH

BK

 

 

 

W

 

 

 

 

 

 

1

W

 

 

 

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PR

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

9

101112 1314

15 16

 

4

BK

 

 

 

 

 

 

J5

 

 

 

 

 

COMBUSTION

1

2 3 4

5 6 7 8

 

5

 

 

 

 

 

 

W

 

 

 

BLOWER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

R

 

 

 

 

 

 

PR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y

 

 

 

 

 

1 G

 

 

 

 

 

 

 

7

120V/24V

 

3 PIN

 

 

 

 

 

 

 

 

 

GAS VALVE

 

 

2

 

 

BK

 

 

 

 

 

TRANSFORMER

CONNECTOR

 

SUPPLY WATER SENSOR

 

 

 

 

 

PK

 

W

 

W

3

 

 

 

 

 

 

 

 

 

 

DISPLAY

 

 

 

 

 

 

 

 

 

 

 

(RED CONNECTOR)

 

 

 

 

 

 

BR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BK

 

BK

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BK

 

 

 

 

 

BL BR

3 PIN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

WIRE LEGEND:

 

CONNECTOR

 

 

W

RETURN WATER SENSOR

 

 

BK

 

 

 

 

 

 

 

 

 

 

 

 

BK

 

(BLUE CONNECTOR)

 

 

 

 

 

FACTORY WIRED

 

 

 

 

6

FLUE GAS SENSOR

 

 

 

 

 

 

 

 

FIELD WIRED, FIELD SUPPLIED

 

 

 

 

 

 

 

(1/4" TABS)

 

 

 

 

 

 

 

 

 

 

1 PROVIDE DISCONNECT MEANS & OVERLOAD PROTECTION AS

 

 

 

 

 

 

 

 

 

 

CAUTION:

 

 

 

 

REQUIRED.

 

 

 

 

WATER HIGH

 

LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS.

IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE

 

LIMIT

J13

WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION.

APPLIIANCE MUST BE REPLACED, IT MUST BE REPLACED

(1/4" TABS)

 

"VERIFY PROPER OPERATION AFTER SERVICING".

 

 

 

WITH TYPE 105°C OR ITS EQUIVALENT.

 

 

 

 

 

 

Figure 15a. Schematic wiring diagram.

Image 18
Contents Installation and Operating Instructions Ratings and Dimensions Jaguar J-390 BoilerLocation and Identification of Parts Location and identification of partsBoiler Foundation SafetyBoiler Location Minimum Clearances from Combustible ConstructionsContamination Prevention NON-DIRECT Vent InstallationDirect Vent Installation Products to AvoidFlue GAS Venting Requirements Vent and AIR Intake MaterialsPVC/CPVC Pipe General Assembly Method Vent and AIR Intake RestrictionsVent Termination Location and Clearances Venting InstallationSidewall Venting NON-DIRECT Vent NON-DIRECT Vent Vertical VentingJaguar J-390 NON-DIRECT VENT, Sidewall Venting 10 MAXJaguar J-390 NON-DIRECT VENT, Venting Through a Roof FT. MINFT. MIN Jaguar J-390 Direct VENT, Sidewall Venting Thick WallDIA PVC/CPVC Pipe for Vent Combustion Screw Jaguar Model J-390 Direct Vent Venting and AIR Intake Through a Roof FT. MINCommonwealth of Massachusetts Special Requirement Venting and AIR Intake System Regular InspectionCondensate Removal System GAS PipingDomestic HOT Water Tank Thermostat Electrical WiringSpace Heating Thermostats Outdoor AIR Sensor101112 Boiler Control 120V 3 4 5 6 7 3 4 5 6 7 Thermostat Water Piping Water Outlet Piping Jaguar Tank PipingFeet w.c Zoning with circulators Zoning with zone valves Piping a heating-cooling system to the boiler and a chiller Operating Instructions Filling and Venting Water Systems View and Changing TemperaturesViewing and changing system setting Before Firing BOILER, make these checksJaguar Boiler Display Board Boiler Operation StatusViewing and Changing Temperatures If outdoor sensor is usedBoiler model selection, value is 5 for model J-390 Water Instructions Safety InformationIII. Initial Start To Turn OFF GAS to ApplianceJaguar Model J-390 Sequence of Operation Gas valve adjustment IV. Check Combustion and Fuel Input RateVI. Diagnostic Error Codes Safety CheckControl Safety Shutdown test Check for gas leaks19, 42 Going to the sensor, or replace the sensor. If no sen III. Cleaning Care and MaintenanceGeneral Maintenance If Replacement Parts are NeededGeneral Troubleshooting Guide for Service Personnel Jaguar Model J-390 SLANT/FIN CORPORATION, Greenvale, N.Y Phone 516