Slant/Fin J-390 installation instructions Thermostat

Page 23

Jaguar Model J-390

23

 

 

 

 

MULTIZONING OF "JAGUAR" BOILER;

 

 

PUMP ZONING SYSTEM USING R882A/B RELAYS

 

ZONE 3

 

 

 

 

THERMOSTAT

 

 

 

 

 

 

ZONE 2

ZONE 1

 

 

THERMOSTAT

 

 

THERMOSTAT

 

 

 

 

DISCONNECT

 

 

 

 

 

 

 

 

SWITCH

 

 

 

 

LI

 

 

 

 

1

R882A/B

R882A/B

R882A/B

 

L2

 

120V/60HZ

 

 

 

120V/24V

 

 

 

 

 

 

 

TRANSFORMER

 

CIRC.

CIRC.

 

CIRC.

 

ZONE 3

ZONE 2

 

ZONE 1

 

1 2 3 4 5 6 7 8

FIELD WIRING

TERMINALS ON BOILER

1POWER SUPPLY, PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.

Figure 16c. Multizoning of Jaguar boiler; pump zoning system using R882A/B relays.

THERMOSTAT

 

T

T

THERMOSTAT

120 V / 24 V

TRANSFORMER

 

DISCONNECT SWITCH

R845A

 

 

 

 

 

RELAY

 

 

 

 

 

1

2

3

4

5

6

DISCONNECT

SWITCH

 

1

CIRCULATOR

LI

 

 

 

L2

R 882A/B

RELAY

CIRCULATOR

LI

L2

1

1POWER SUPPLY, PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

 

 

FIELD WIRING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TERMINALS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON BOILER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1POWER SUPPLY, PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.

1

2

3

4

5

6

7

8

 

 

FIELD WIRING

 

 

 

 

 

 

 

 

 

 

 

TERMINALS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON BOILER

 

 

 

 

 

 

 

 

 

 

 

Figure 16d. Single zoning of Jaguar boiler; pump zoning system using R845A relay.

Figure 16e. Single zoning of Jaguar boiler; pump zoning sys- tem using R882A/B relay.

Image 23
Contents Installation and Operating Instructions Jaguar J-390 Boiler Ratings and DimensionsLocation and identification of parts Location and Identification of PartsMinimum Clearances from Combustible Constructions SafetyBoiler Location Boiler FoundationProducts to Avoid NON-DIRECT Vent InstallationDirect Vent Installation Contamination PreventionVent and AIR Intake Materials Flue GAS Venting RequirementsVent and AIR Intake Restrictions PVC/CPVC Pipe General Assembly MethodNON-DIRECT Vent Vertical Venting Venting InstallationSidewall Venting NON-DIRECT Vent Vent Termination Location and Clearances10 MAX Jaguar J-390 NON-DIRECT VENT, Sidewall VentingFT. MIN Jaguar J-390 NON-DIRECT VENT, Venting Through a RoofFT. MIN Thick Wall Jaguar J-390 Direct VENT, Sidewall VentingDIA PVC/CPVC Pipe for Vent Combustion Screw Jaguar Model J-390 FT. MIN Direct Vent Venting and AIR Intake Through a RoofGAS Piping Venting and AIR Intake System Regular InspectionCondensate Removal System Commonwealth of Massachusetts Special RequirementOutdoor AIR Sensor Electrical WiringSpace Heating Thermostats Domestic HOT Water Tank Thermostat101112 Boiler Control 120V 3 4 5 6 7 3 4 5 6 7 Thermostat Water Piping Water Outlet Piping Feet w.c JaguarTank Piping Zoning with circulators Zoning with zone valves Piping a heating-cooling system to the boiler and a chiller Before Firing BOILER, make these checks View and Changing TemperaturesViewing and changing system setting Operating Instructions Filling and Venting Water SystemsBoiler Operation Status Jaguar Boiler Display BoardIf outdoor sensor is used Viewing and Changing TemperaturesBoiler model selection, value is 5 for model J-390 Water To Turn OFF GAS to Appliance Safety InformationIII. Initial Start InstructionsJaguar Model J-390 Sequence of Operation IV. Check Combustion and Fuel Input Rate Gas valve adjustmentCheck for gas leaks Safety CheckControl Safety Shutdown test VI. Diagnostic Error Codes19, 42 Going to the sensor, or replace the sensor. If no sen If Replacement Parts are Needed Care and MaintenanceGeneral Maintenance III. CleaningGeneral Troubleshooting Guide for Service Personnel Jaguar Model J-390 SLANT/FIN CORPORATION, Greenvale, N.Y Phone 516