Slant/Fin J-390 installation instructions 120V

Page 20

20

 

 

 

 

 

 

Jaguar Model J-390

L1

HOT

120V/60HZ

 

 

NEUTRAL

L2

GND

 

DISCONNECT

 

 

 

 

 

 

 

 

SWITCH

 

 

 

 

 

 

 

 

BOILER ON/OFF

 

 

 

 

 

 

 

SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

COMBUSTION

 

 

 

 

 

 

 

BLOWER

 

 

 

 

 

 

M

 

BOILER

 

 

 

 

 

 

CIRCULATOR

 

 

 

 

 

 

 

 

M

DHW CIRCULATOR

 

 

120V SECTION OF

WATER HIGH

(IF USED)

 

 

 

 

 

 

 

 

 

 

CONTROL BOARD

 

LIMIT

 

GAS

 

 

 

 

 

 

 

 

 

 

 

 

 

120V

24V

VALVE

 

 

 

 

 

 

 

 

120V

 

 

 

 

 

SPARK

 

 

 

 

 

 

 

ELECTRODE

 

 

 

 

 

 

 

 

 

 

 

 

 

COMBUSTION

 

 

 

 

 

 

 

BLOWER

 

 

 

10V

 

 

 

 

"CALL FOR HEAT"

CHASSIS

 

 

 

 

 

 

 

24V ROOM THERMOSTAT

GND

 

 

 

 

 

 

 

OR ISOLATED CONTACT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DHW THERMOSTAT

 

 

 

 

 

 

 

(IF USED) OR SENSOR

 

 

 

 

 

 

 

 

LOW WATER CUT OFF

 

 

 

 

 

 

 

(IF USED) OR JUMPER

 

MICRO

 

 

 

 

SUPPLY WATER

 

 

PROCESSOR

 

 

 

SENSOR

 

 

ON CONTROL

 

 

 

 

RETURN WATER

 

BOARD

 

 

 

 

 

SENSOR

 

 

 

 

 

 

 

FLUE GAS

 

 

 

 

 

 

 

 

SENSOR

 

 

 

 

 

 

 

OUTDOOR SENSOR

 

 

 

 

 

 

 

(IF USED)

 

 

 

 

 

 

 

 

 

DISPLAY

Figure 15c. Ladder wiring diagram.

Image 20
Contents Installation and Operating Instructions Ratings and Dimensions Jaguar J-390 BoilerLocation and Identification of Parts Location and identification of partsSafety Boiler LocationBoiler Foundation Minimum Clearances from Combustible ConstructionsNON-DIRECT Vent Installation Direct Vent InstallationContamination Prevention Products to AvoidFlue GAS Venting Requirements Vent and AIR Intake MaterialsPVC/CPVC Pipe General Assembly Method Vent and AIR Intake RestrictionsVenting Installation Sidewall Venting NON-DIRECT VentVent Termination Location and Clearances NON-DIRECT Vent Vertical VentingJaguar J-390 NON-DIRECT VENT, Sidewall Venting 10 MAXJaguar J-390 NON-DIRECT VENT, Venting Through a Roof FT. MINFT. MIN Jaguar J-390 Direct VENT, Sidewall Venting Thick WallDIA PVC/CPVC Pipe for Vent Combustion Screw Jaguar Model J-390 Direct Vent Venting and AIR Intake Through a Roof FT. MINVenting and AIR Intake System Regular Inspection Condensate Removal SystemCommonwealth of Massachusetts Special Requirement GAS PipingElectrical Wiring Space Heating ThermostatsDomestic HOT Water Tank Thermostat Outdoor AIR Sensor101112 Boiler Control 120V 3 4 5 6 7 3 4 5 6 7 Thermostat Water Piping Water Outlet Piping Feet w.c JaguarTank Piping Zoning with circulators Zoning with zone valves Piping a heating-cooling system to the boiler and a chiller View and Changing Temperatures Viewing and changing system settingOperating Instructions Filling and Venting Water Systems Before Firing BOILER, make these checksJaguar Boiler Display Board Boiler Operation StatusViewing and Changing Temperatures If outdoor sensor is usedBoiler model selection, value is 5 for model J-390 Water Safety Information III. Initial StartInstructions To Turn OFF GAS to ApplianceJaguar Model J-390 Sequence of Operation Gas valve adjustment IV. Check Combustion and Fuel Input RateSafety Check Control Safety Shutdown testVI. Diagnostic Error Codes Check for gas leaks19, 42 Going to the sensor, or replace the sensor. If no sen Care and Maintenance General MaintenanceIII. Cleaning If Replacement Parts are NeededGeneral Troubleshooting Guide for Service Personnel Jaguar Model J-390 SLANT/FIN CORPORATION, Greenvale, N.Y Phone 516