INSTALLATION INSTRUCTIONS
SITE REQUIREMENTS
2. FLUE OPTIONS
REAR EXIT (8708)
• Cut to length as required on site
1
200 mm min
500 mm max
AR0630
Guard Supplied.
TOP EXITS
2.1 TOP FLUE UP & OUT KIT (8534)
This flue is vertical from the top of the appliance then horizontally out. (See Diagram 2). The basic kit comprises:
1 x 200mm vertical length
1 x 500mm terminal length (cut to length on site)
1 x 90° elbow
1 x wall plate
1 x 70mm restrictor
1 x 60mm restrictor
2
AR1671
NOTE:
The start of the bend to the centre line of horizontal flue is 170mm.
The centre line of vertical flue to end of bend is 220mm.
2.2TOP FLUE UP & OUT WITH ADDITIONAL BEND
3
When A = 1.0 to 1.499 metes B & C = 1.0 metres maximum
When A = 1.499 metres to 3.0 metres B & C = 4.0 metres maximum
AR1672
Any additional bend may be used on the horizontal section (either 45° or 90°), but the overall horizontal flue run will be reduced. Refer to Diagram 3.
13