Stovax Studio 22 manual Magnetic safety valve, Control BOX, Main injector, Primary Aeration Plate

Page 35

SERVICING INSTRUCTIONS

REPLACING PARTS

11.magnetic safety valve

11.1To replace the magnetic safety valve:

Undo the thermocouple from the interrupter block and remove the two thermo current cables

Unscrew the interrupter block from the back of the valve

Undo the silver magnetic valve retaining but on the back of the valve.

Gently tap out the mag valve

Replace with a new unit

Reassemble in reverse order

12.CONTROL BOX

Remove the two thermo current cables by removing the two screws, Diagram 17

Remove the ignition lead, Diagram 17

Remove the eight loom wire from the control box,

Diagram 17

17

Eight wire

 

 

cable

 

Thermo current

cables

Ignition lead

Touch pad extension cable

Battery extension cable

AR1915

Remove the battery extension cable, Diagram 17

Remove the touch pad extension cable

The control box can now be replaced.

After replacing the control box you may need to reprogram the handset:

Press and hold the reset button on the control box until you hear two signals. After the second longer signal:

Release the reset button and within 20 seconds

Press the DOWN button on the handset until you hear an additional long signal confirming the new code

13.main injector

13.1To change the main injector:

Undo the injector feed pipe

Undo the lock nut from the injector

Replace with the correct size injector

14. Primary Aeration Plate

NOT ALL MODELS HAVE AERATION PLATES. REFER TO NOTE AT BEGINNING OF INSTALLATION INSTRUCTIONS.

14.1Remove the burner module as described in Servicing

Section 2.

14.2Remove the fixing screw and slide the plate off the venturi.

14.3Replace with the correct size plate and secure with the screw. Ensure the lower edge of the plate is located over the venturi flange. See Diagram 18.

18

AR0766

15. Changing between Gas Types

In order to change between gas types, it will be necessary to change the following items:

Burner Unit

Pilot Injector

Control Valve

Injector

Aeration Plate (if required)

Data badge

A kit of parts is available for this, always quote the Model number and Serial number when ordering any spare parts.

NOTE: THE CONTROL VALVE IS FACTORY PRESET FOR THE CORRECT GAS TYPE AND MODEL, A NEW UNIT WILL NEED TO BE ORDERED WHEN CHANGING BETWEEN GAS TYPES.

35

Image 35
Contents Studio Studio 22 Balanced flue 8704BFLEC P8704BFLEC Covering the Following ModelGAS CHECK FLUE CHECKFail General MAN ModeIncreasing Temperature Decreasing TemperatureSetting the Time Temp ModeTimer Mode LOW BatteryAll models Cleaning the StudioChanging the Studio Batteries Arrangement of Fuel BED Advice on Handling and Disposal of Fire CeramicsFire will not Light HOT SURFACESCAT Technical SpecificationCovering the Following Models Studio 22 BF 8704BFLEC P8704BFLECQty Description Fixing Kit containing Packing ChecklistBauhaus Frame Dimensions Size mm Steel Frame Dimensions Size mmProfil Frame Dimensions Size mm Flue and Chimney Requirements SITE REQUIREMENTSTOP Flue UP & OUT KIT Flue OptionsRear Exit TOP ExitsGAS Supply TOP Flue Vertical KIT 8524/8524ANTOP Flue Vertical Offset KIT 8530/8530AN Extra Flue LengthsAppliance Location Installation of the appliance InstallationSafety Precautions AR2117 Distance to Combustible Material Stud Work InstallationSlips Flue system see Installation, Flue AssemblyApply a plaster finish to the chimney breast Studwork for Cool Wall Installation KIT Flue Assembly TOP Exit Vertical Including Offset Wall Thickness MINMAX TOP Exit Vertical & Horizontal FlueAdd 10 mm to the outlet end Assembling the ApplianceArrangement of Fuel BED AR02123 Lighting the Studio Thermostatic Remote ControlCommissioning CommissioningCheck Servicing / Fault Finding ChartsSymptom Cause Remedy Servicing RequirementsFlame Failure Functional Check Ignition Functional CheckDecorative Frame Replacing PartsWindow Frame Assembly GeneralMaIN Burner MaIN Control AssemblyVermiculite Panels Electrode Pilot Unit AssemblyPilot Burner Bracket Thermocouple Ignition LeadGAS Valve Pilot InjectorPrimary Aeration Plate Magnetic safety valveControl BOX Main injectorFollow , Main Control Assembly Pressure and Leak Testing the ApplianceComponent Short Spares List Studio7TH Service 1ST Service3RD Service 5TH ServiceMember of the Stovax Group