Stovax Studio 22 manual Servicing / Fault Finding Charts, Servicing Requirements, Check

Page 29
REPLACE BATTERIES BEFORE ATTEMPTING TO RECTIFY ANY FAULTS.
IF THE FIRE DOES NOT WORK, BUT HAS WORKED IN THE PAST:
• CHECK THE EMERGENCY SHUT OFF SWITCH
IN THE BOTTOM RIGHT CORNER BY THE DOOR IS SWITCHED ON, SEE USER SECTION, PAGE 6
Electronic Control Valve Fault Analysis

SERVICING INSTRUCTIONS

SERVICING / FAULT FINDING CHARTS

1. SERVICING REQUIREMENTS

This appliance must be serviced at least once a year by a competent person.

All tests must be carried out in accordance with the current CORGI recommendations.

1.1Before any tests are undertaken on the appliance:

Conduct a gas soundness test for the property to ensure there are no gas leaks prior to starting work

1.2• Fully check the operation of the appliance

Special checks

1.2.1Clean any lint or fluff from the pilot - pay particular attention to the aeration holes of the pilot

1.2.2Clean away any fluff or lint from under the burner

1.2.3Check the spark gap on the pilot is correct

Correct any faults found during the initial tests

Recommission the appliance conducting the usual safety checks

1.3Advise the customer of any remedial action taken.

Symptom

Cause

Remedy

 

 

 

3 Short beeps from

Batteries low in

Replace appliance

control

appliance

batteries

 

 

 

No ignition, 5 second

1. On/Off switch is in

1. Move switch to

continuous tone (there

OFF position

ON position

may be several short

2. Loose/damaged

2 Check interrupter

beeps before)

wire

block and wires

 

 

 

No ignition, no tone,

Receiver board

Replace receiver

motor turns slightly when

damaged

 

operated

 

 

No pilot flame and

Thermocouple circuit

Correct wiring

control continues to

wired incorrectly

 

spark

 

 

 

 

 

Pilot lights, control

1. No spark at pilot

1. Rectify spark at

continues to spark, value

burner

pilot burner

shuts down after 10 - 30

2. Loose/damaged

2. Check interrupter

seconds

wire

and wires

 

 

 

CHECK 1

pilotassembly, clean the area.

Yes

Does the pilot light?

No

Is the control being operated correctly?

Yes

Will the pilot light with a match?

No

 

 

 

gas turned on to the appliance?

Yes

gas pressure correct?

 

 

Is the

 

 

Is the

Yes

Has the system got any air in it?

 

 

No

the inlet test point, leads for correct orientation,

SYSTEM OK

IGNITION FUNCTIONAL

PILOT WILL NOT LIGHT

around the

short the spark,

there is no debris

etc.) which could

Ensure

(e.g. soot,

Yes

 

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operate the valve. Is there a spark?

 

Consult User Instructions and retry.

 

 

 

 

 

 

No

 

 

 

 

 

 

 

 

 

 

Yes

Check alignment of pilot burner head, change the ignition lead. See Replacing Parts, section 2.

No

 

 

No

 

 

 

 

 

 

 

 

 

 

 

Check isolation tap and gas meter, retry.

 

 

 

 

 

 

 

Correct and retry.

 

 

 

 

 

Yes

Purge the gas pipes and retry.

There is a blockage in the system, check the mag seating and valve. Check thermocouple condition and connection

GO TO THE NEXT CHART IGNITION FUNCTIONAL CHECK 2

29

Image 29
Contents Studio Studio 22 Balanced flue 8704BFLEC P8704BFLEC Covering the Following ModelGAS CHECK FLUE CHECKFail Increasing Temperature MAN ModeDecreasing Temperature GeneralTimer Mode Temp ModeLOW Battery Setting the TimeAll models Cleaning the StudioChanging the Studio Batteries Arrangement of Fuel BED Advice on Handling and Disposal of Fire CeramicsFire will not Light HOT SURFACESCovering the Following Models Technical SpecificationStudio 22 BF 8704BFLEC P8704BFLEC CATQty Description Fixing Kit containing Packing ChecklistBauhaus Frame Dimensions Size mm Steel Frame Dimensions Size mmProfil Frame Dimensions Size mm Flue and Chimney Requirements SITE REQUIREMENTSRear Exit Flue OptionsTOP Exits TOP Flue UP & OUT KITTOP Flue Vertical Offset KIT 8530/8530AN TOP Flue Vertical KIT 8524/8524ANExtra Flue Lengths GAS SupplyAppliance Location Installation of the appliance InstallationSafety Precautions AR2117 Distance to Combustible Material Stud Work InstallationSlips Flue system see Installation, Flue AssemblyApply a plaster finish to the chimney breast Studwork for Cool Wall Installation KIT Flue Assembly MAX Wall Thickness MINTOP Exit Vertical & Horizontal Flue TOP Exit Vertical Including OffsetAdd 10 mm to the outlet end Assembling the ApplianceArrangement of Fuel BED AR02123 Lighting the Studio Thermostatic Remote ControlCommissioning CommissioningSymptom Cause Remedy Servicing / Fault Finding ChartsServicing Requirements CheckFlame Failure Functional Check Ignition Functional CheckWindow Frame Assembly Replacing PartsGeneral Decorative FrameMaIN Burner MaIN Control AssemblyVermiculite Panels Electrode Pilot Unit AssemblyPilot Burner Bracket GAS Valve Ignition LeadPilot Injector ThermocoupleControl BOX Magnetic safety valveMain injector Primary Aeration PlateFollow , Main Control Assembly Pressure and Leak Testing the ApplianceComponent Short Spares List Studio3RD Service 1ST Service5TH Service 7TH ServiceMember of the Stovax Group