Stovax Studio 22 manual AR02123

Page 26

INSTALLATION INSTRUCTIONS

INSTALLATION

37

A

AR2121

10.3Place Log B on the ledge at the rear of the fire, Diagram

38.

38

B

A

AR2122

10.4Put Log C so that the back end sits in the groove in the rear of Log B and the front left rests in the cut-out groove in Log A, Diagram 39.

39

B

C

A

AR02123

10.5Position Log D so that the underneath rests in the groove of Log A, and the triangular groove in the base of Log D fits into the corner of the burner, Diagram 40.

40

D

A

AR2124

10.6Put the groove in the base of Log E into the indent on the right of Log A. The left branch rests on the upper end of Log

C, Diagram 41.

41

E

A

AR2125

10.7Log F rests against Log B at its far right end, between Log B and the side panel. The front end of Log F sits on the front panel, see Diagram 42

42

B

F

AR2126

When closing the door ensure the door catches are fully engaged:

Slide the allen key into the gap between the door and frame and locate the catch of the lower lock

Push the allen key DOWN

Slide the allen key into the gap and locate the upper lock

Push the allen key UP

26

Image 26
Contents Studio Covering the Following Model Studio 22 Balanced flue 8704BFLEC P8704BFLECGAS CHECK FLUE CHECKFail Decreasing Temperature MAN ModeIncreasing Temperature GeneralLOW Battery Temp ModeTimer Mode Setting the TimeAll models Cleaning the StudioChanging the Studio Batteries Advice on Handling and Disposal of Fire Ceramics Arrangement of Fuel BEDHOT SURFACES Fire will not LightStudio 22 BF 8704BFLEC P8704BFLEC Technical SpecificationCovering the Following Models CATPacking Checklist Qty Description Fixing Kit containingBauhaus Frame Dimensions Size mm Steel Frame Dimensions Size mmProfil Frame Dimensions Size mm SITE REQUIREMENTS Flue and Chimney RequirementsTOP Exits Flue OptionsRear Exit TOP Flue UP & OUT KITExtra Flue Lengths TOP Flue Vertical KIT 8524/8524ANTOP Flue Vertical Offset KIT 8530/8530AN GAS SupplyAppliance Location Installation of the appliance InstallationSafety Precautions AR2117 Stud Work Installation Distance to Combustible MaterialFlue system see Installation, Flue Assembly SlipsApply a plaster finish to the chimney breast Studwork for Cool Wall Installation KIT Flue Assembly TOP Exit Vertical & Horizontal Flue Wall Thickness MINMAX TOP Exit Vertical Including OffsetAssembling the Appliance Add 10 mm to the outlet endArrangement of Fuel BED AR02123 Thermostatic Remote Control Lighting the StudioCommissioning CommissioningServicing Requirements Servicing / Fault Finding ChartsSymptom Cause Remedy CheckIgnition Functional Check Flame Failure Functional CheckGeneral Replacing PartsWindow Frame Assembly Decorative FrameMaIN Burner MaIN Control AssemblyVermiculite Panels Electrode Pilot Unit AssemblyPilot Burner Bracket Pilot Injector Ignition LeadGAS Valve ThermocoupleMain injector Magnetic safety valveControl BOX Primary Aeration PlatePressure and Leak Testing the Appliance Follow , Main Control AssemblyShort Spares List Studio Component5TH Service 1ST Service3RD Service 7TH ServiceMember of the Stovax Group