Ensure there is a sufficient water supply.
Make sure the float switch can move unrestricted.
Motor hums but does not start:
xPump blocked by foreign object. Clean pump.
Pump does not pump properly:
xDelivery head too high.
Observe max. delivery head (see "Technical Specifications").
xDischarge hose kinked.
Straighten discharge hose.
xDischarge hose leaky.
Seal discharge hose, tighten screw fittings.
Pump runs very noisy:
xPump primes air.
Ensure there is a sufficient water supply.
Adjust float switch correctly.
Hold pump at an angle when sub- merging.
Pump runs continuously:
xFloat switch does not reach lower position.
Make sure the float switch can move unrestricted.
9. Repairs
ADanger!
Repairs to electric tools must
only be carried out by a qualified electrician!
ENGLISH
Electric tools in need of repair can be sent to an authorised service center in your country. See spare parts list for address.
Please attach a description of the fault to the electric tool.
10. Environmental Protection
The packaging of the pump can be 100 % recycled.
Worn out power tools and accessories contain considerable amounts of valua- ble raw and plastic materials, which can be recycled.
These instructions are printed on chlo-
11. Technical Specifications
Mains voltage | V | 230 a 1 |
|
|
|
Frequency | Hz | 50 |
|
|
|
Rated output | W | 1000 |
|
|
|
Rated current | A | 4.4 |
|
|
|
Fuse protection min. | A | 10 |
|
|
|
Running capacitor | PF | 12.5 |
|
|
|
Rated speed | 2800 | |
Pump capacity max. | l/h | 7500 |
|
|
|
Delivery head max. | m | 36 |
|
|
|
Delivery pressure max. | bar | 3.6 |
|
|
|
Immersion depth max. | m | 10 |
|
|
|
Standing water max. | mm | 30 |
|
|
|
Temperature of the primed medium max. | °C | 35 |
|
|
|
Degree of protection |
| IP 68 |
|
|
|
Protection class |
| I |
|
|
|
Insulation class |
| B |
|
|
|
Materials |
|
|
Pump casing |
| Polypropylene |
Pump shaft |
| Stainless steel |
Impeller |
| Noryl |
|
|
|
Power cable (HO 7 | m | 15 |
|
|
|
Discharge port (AG=male, IG=female) |
| 1" IG |
|
|
|
Dimensions (pump casing) |
|
|
Height | mm | 470 |
Diameter | mm | 150 |
|
|
|
Weight | kg | 8.2 |
|
|
|
Max. length of extension cable |
|
|
at 3 x 1.0 mm2 lead | m | 30 |
at 3 x 1,5 mm2 lead | m | 50 |
11