Jotul Woodstove F 400 manual Assembly Before Installation, Chimney Requirements, Masonry Chimneys

Page 4

USA/Canada

Assembly Before Installation

Unpack the Stove

Inspect the stove for damage. Contact your dealer immediately if any damage is found. Do not install the stove if any damage is evident.

Contents:

Inspection Cover (Not for use in US/Canada)

Door Handle

Hardware Bag

Flue Collar Reversal

The Flue Collar is oriented in the Top Exit position. If a Rear Exit position is required, remove the two mounting bolts, and turn the collar 180 degrees. Secure the collar using the same bolts, nuts and washers.

Chimney Connector

Use 6” single wall or listed 6” double-wall stovepipe to connect the stove to the chimney. Single wall stovepipe must be black iron or stainless steel and have a minimum thickness of 24 gauge. Do not use aluminum or galvanized steel pipe for chimney connection - these materials are not suitable for use with solid fuel.

Follow these guidelines regarding chimney connector construction:

Do not use chimney connector as a chimney.It is intended only for use as a connection device.

Each connector section must be oriented with the male (crimped) end pointing toward the stove. See fig. 2.

Secure all connector joints with three sheet metal screws.

For the best performance, the chimney connector should be as short and direct as possible, including no more than two 90° elbows.

The maximum vertical run of single wall stovepipe should not exceed 10 ft. (305 cm). The maximum horizontal run should not exceed 3 ft. (92 cm) with a 1/4” rise per foot.

No part of the chimney connector may pass through an attic or roof space, closet or other concealed space, or through a floor or ceiling. All sections of the chimney connectors must be accessible for cleaning. Where passage through a wall or partition of combustible construction is desired, the installation must conform with NFPA 211 or CAN/CSA-B365, and is also addressed in this manual.

Do not connect this stove to a chimney flue servicing another appliance.

Chimney Requirements

There are two types of chimneys suitable for the Jøtul F

400:

1.A code-approved masonry chimney with a ceramic tile or listed steel flue liner.

2.A prefabricated chimney complying with the requirements for Type HT (2100°F) chimneys per UL 103 or ULC S629.

The chimney size should not be less than the cross-sectional area of the flue collar, and not more than three times greater than the cross-sectional area of the flue collar.

When selecting a chimney type and the location for the chimney in the house, keep this in mind: It is the chimney that makes the stove work, not the stove that makes the chimney work. This is because a chimney actually creates a suction, called “draft” which pulls air through the stove. Several factors affect draft: chimney height, cross-sectional area (size), and temperature of the chimney, as well as the proximity of surrounding trees or buildings.

A short masonry chimney on the exterior of a house will give the poorest performance. This is because it can be very difficult to warm the chimney thereby creating inadequate draft. In extremely cold climates, it may be necessary to reline the chimney or extend its height to help establish draft.

A tall, interior masonry chimney is easier to keep warm and will perform the best under a variety of weather and environmental conditions.

The following guidelines give the necessary chimney requirements based on the national code (ANSI-NFPA 211 for the US. And CSA CAN-B365 for Canada). However, many local codes differ from the national code to take into account climate, altitude, or other factors. Your local building inspector is the final approving authority. Consult them prior to installation.

Do not connect the stove to any air distribution duct or system.

Masonry Chimneys

When installing the Jøtul F 400 into a masonry chimney you must conform to all of the following guidelines:

The masonry chimney must have a fireclay liner or equivalent, with a minimum thickness of 5/8” (14 mm) and must be installed with refractory mortar. There must be at least ½” (12.7 mm) air space between the flue liner and chimney wall.

The fireclay flue liner must have a nominal size of 8” X 8” (20 cm x 20 cm), and should not be larger than 8”X 12” (20 cm x 30 cm). A round fireclay liner must have a minimum inside diameter of 6” (15 cm) and maximum inside diameter of 8” (20 cm). A larger chimney should be relined with an appropriate code approved liner.

4

Image 4
Contents Jøtul F Standards Check Building CodesInstallation Safety NoticesTable of Contents Chimney Requirements Assembly Before InstallationMasonry Chimneys Chimney Height Prefabricated ChimneysWall Pass-Throughs Clearance to Combustibles Masonry ChimneyHearthmount into a Masonry Fireplace Clearances to Walls and CeilingsAlcove Installation Using Shields to Reduce ClearancesMobile Home Installation Corner Installation Jøtul F 400 Woodstove ClearancesUnprotected Surface Parallel to the WallPER NFPA211 or CAN/CSA -B365-M93 Side Rear CornerBreak-In Procedure OperationUse Solid Wood Fuel Only Controls on the Jøtul FMaintenance Adding FuelAsh Removal Glass CareGeneral Maintenance AccessoriesStove-Top Thermometer # Outside Air Kit #154335Floor Bracket Kit #750304 Rear Heat Shield #25 3/4 23 1/4 29 1/2 top exit 25 1/2 rear exit 28 1/2 26 1/2 USA/Canada Draw. no USA/Canada Parts list for the Jøtul F 400 woodstove Consult your dealer for part numbers and replacement partsAppendix a Alternate floor protectionPage Norsk Forhold til myndighetene InnholdInstallasjon av Jøtul F Montering av røykrør Kontroll av funksjoner figTilslutning til skorstein Bruksanvisning VedlikeholdServicearbeider EkstrautstyrSvenska Innehåll SäkerhetsreglerInstallation av Jøtul F Kontroll av funktioner Montering av rökrörAnslutning till skorsten Första gångs upptändning och dagligt användandeUnderhåll Servicearbeten Extrautrustning/tillbehörPre-installation checks Table of contentsRelationship to the authorities Installation of Jøtul F Assembly prior to installation Control of functions figMounting of flue pipe Connection to chimneyCleaning the glass Cleaning and soot removalOperating instructions Initial lighting and daily useService Optional equipmentRéglementations nationales Table des matieresInstallation du poêle Jøtul F400 Mise en service et usage courant Mise en serviceMontage du tuyau de raccordement Raccordement à la cheminéeEntretien Accessoires optionnels RevisionÍndice de contenido Comprobaciones previas a la instalaciónInstalación de Jøtul F Montaje previo a la instalación Control de funciones figInstalación del conducto de humos Conexión a la chimeneaMantenimiento Encendido inicial y uso diarioLimpieza del cristal Eliminación de la cenizaConservación Equipo opcional Sustitución de la placa deflectoraConformità alle leggi Indice generaleInstallazione di Jøtul F Controllo delle funzioni fig Montaggio del condottoCollegamento alla cappa Prima accensione e utilizzo quotidianoManutenzione Pulizia del vetroEliminazione della cenere Pulizia del camino ed eliminazione della fuliggineRiparazione Dotazione facoltativaBehördliche Auflagen InhaltAufstellen des Jøtul F Installation des Abzugsrohrs Zusammenbau vor der AufstellungSteuergeräte Abb Anschluss an den SchornsteinInbetriebnahme Inbetriebnahme und täglicher GebrauchInbetriebnahme Täglicher GebrauchPflege Austausch der Hitzeschutzplatten InstandhaltungAustausch der Umlenkplatte Wettelijke voorschriften Controle voor de installatieInhoudsopgave Installatie van de Jøtul F Gebruiksaanwijzing Controle van de functies afbPlaatsing van de kachelpijp SchoorsteenaansluitingOnderhoud Optionele accessoires Groot onderhoudPage Page Page Page Kvalitet QualitätQuality Qualité

Woodstove F 400 specifications

The Jotul F 400 is a leading model in the Jotul line of woodstoves, renowned for its combination of efficiency, aesthetics, and robust craftsmanship. As one of the company's most popular models, it seamlessly blends functionality with timeless design, making it an ideal choice for both contemporary and traditional spaces.

One of the primary features of the Jotul F 400 is its impressive heating capacity. With an ability to heat spaces of up to 2,000 square feet, this woodstove is perfect for larger rooms or open floor plans. Its firebox can accommodate logs up to 20 inches in length, allowing for longer burn times and fewer refuels. With an average efficiency rating of around 78%, the F 400 ensures that most of the wood's energy is converted into usable heat rather than lost up the chimney.

In terms of design, the Jotul F 400 showcases the classic Norwegian aesthetic that Jotul is known for. Its cast iron construction not only contributes to its durability but also aids in heat retention, ensuring that the stove continues to radiate warmth long after the fire has diminished. The intricate detailing and optional enamel finishes give it an elegant touch, making it a statement piece in any home.

The Jotul F 400 is equipped with advanced combustion technology that promotes a cleaner burn, resulting in reduced emissions. This feature is particularly important in today’s environmentally conscious market, as it aligns with stricter regulations on woodstove emissions. The stove features a secondary combustion system that helps to maximize fuel efficiency while minimizing smoke output, allowing users to enjoy the ambiance of a wood fire without excessive pollutants.

Another notable characteristic of the F 400 is its easy-to-use air control system. This allows users to easily adjust the airflow to the fire, optimizing it for lighting, burning, and maintaining desired temperatures. The large, self-cleaning glass door provides an unobstructed view of the flames, enhancing the ambiance of any room.

In summary, the Jotul F 400 woodstove is a blend of efficiency, beauty, and innovation. Its capacity to heat large spaces, coupled with advanced combustion technology and classic design, makes it one of the top choices for homeowners looking for a reliable and attractive heating solution. Whether for cozy evenings or efficient heating, the Jotul F 400 is sure to enhance any living space.