Installing Wireless Zones

General Information

Zones: The control supports up to 24 wireless zones using 5800 Series transmitters, and up to 16 wireless buttons.

Range: The built-in RF receiver can detect signals from wireless transmitters within a nominal range of 200 feet.

Transmitters: 5800 Series transmitters have built-in serial numbers that must be entered into the system using the 56 or 83 interactive mode, or input to the control via the downloader. 5800 Series transmitters (except the 5800RL and 5827, described separately) do not have DIP switches. Each transmitter's zone number is programmed into the system in 56 mode. Some transmitters, such as the 5816 and 5817, can support more than one "zone" (referred to as loops or inputs). On the 5816, for example, the wire connection terminal block is loop 1,the reed contact is loop 2. Each loop must be assigned a different zone number.

 

The 5816 and 5817 Transmitters do not have EOL supervision of their loop wiring. Therefore, for

UL

UL Household Burglary installations, the loop wiring may not exceed 3 feet.

The 5800RL, 5802MN, 5802MN2, 5804, 5804BD, 5804BDV, 5804E, 5804WATCH, 5814, 5816TEMP,

 

 

5819, 5819S(WHS & BRS), and 5850(GBD) transmitters are not intended for any UL installations.

 

 

For button transmitters (RF "keys") such as the 5804 and 5801, you must assign a unique zone number to each individual button used on the transmitter. Each button on the transmitter also has a pre-designated loop or input number, which is automatically displayed.

House Identification

If you are using a 5804BD/5804BDV, or 5827 Wireless Keypad with the system, you must program a House ID Code (01–31) in field 24 to establish proper communication, and the keypad must be set to the same ID. House ID 00 disables all wireless keypads. An RF House ID is not necessary for other 5800 Series transmitters; the entry should be left at “00” (default) in those cases. The 5827 reports low battery status as zone “00”.

1

2

 

4

3

5

 

7

6

8

*

9

0

 

#

 

 

••••

•••••

•••••

••• ••

5804BD/5804BDV5827

Transmitter Supervision

Except for some transmitters/keypads that may be carried off- premises (5804, 5804BD, 5804BDV, 5804E, 5804WATCH, and 5827), each transmitter is supervised by a check-in signal that is sent to the receiver at 70–90 minute intervals. If at least one check- in is not received from each supervised transmitter within a 12- hour period, the "missing" transmitter number(s) and "FAULT" will

58165806/5807/5808 5890 / 5890PI

be displayed. The supervision for a particular transmitter in the

01009-010-V1

system that may also be carried off the premises (5801, 5802MN)

 

may be turned off by entering it as a "UR" (unsupervised RF) type,

 

as described in the 56 Enhanced Zone Programming Mode section.

 

5800 Series transmitters have built-in tamper protection and will

 

annunciate as a fault condition if covers are removed.

 

Transmitter Input Types

Each of the following transmitters has one or more unique factory-assigned input (loop) ID codes. Each of the inputs requires a programming zone (e.g., a 5804's four inputs require four button zones). Transmitters can be entered as one of the following types (see transmitter’s instructions for appropriate input type):

Type

Description

"RF" (Supervised RF)

Sends periodic check-in signals, as well as fault, restore, and low battery signals. The

 

transmitter must remain within the receiver's range.

"UR" (Unsupervised RF)

Sends all the signals that the "RF" type does, but the control does not supervise the

 

check-in signals. The transmitter may therefore be carried off-premises.

"BR" (Unsupervised Button RF) These only send fault signals. They do not send low battery signals until they are activated. The transmitter may be carried off-premises.

–11–

Image 11
Contents Ademco Lynxr Series Security Systems Recommendations For Proper Intrusion Protection Recommendations for Smoke and Heat DetectorsTable of Contents Two-way voice communication Speaker phone operation System FeaturesHardwire zone Hour backupDesktop Mounting Mounting the ControlWiring Connections Wiring ConnectionsWiring Overview Full Line Seizure Connections This System 150 to 300 feet AC Power and Backup BatteryAC Power and Rechargeable Backup Battery 75 to 150 feetHours minimum At least 1-hour before battery depletion Hours minimum Approximately 1-hour before battery depletionTransmitter Supervision Installing Wireless ZonesGeneral Information House IdentificationGo/No Go Test Mode Transmitter Battery LifeUsing the Transmitter Sniffer Mode Enter Installer code 4112 + # +Setting DIP Switches on the 5800RL and 5827 Transmitters General Programming Information Loading Factory DefaultsExiting Program Mode Mechanics of ProgrammingType 02 Entry/Exit Burglary #2 Zone Response Type DefinitionsType Zone Not Used Type Entry/Exit Burglary #15806/5807/5808 Data Field Descriptions Defaults where applicable are Indicated in TextFields 43 Dialer ProgrammingSplit/Dual Reporting Follow Me Reminder Phone NumberPhone System Select Report Format for Primary/SecondarySystem Status and Restore Report Codes Programming 59 76 System Status Report Codes Restore Report CodesRestore Report Codes Download Information 94 Zone Lists for Menu Mode Enabling the Wireless DialerEnhanced Zone Programming Mode Device Programming Menu ModeWireless Dialer Setup Enabling the 5842 Wireless DialerResponse to phone line tamper Enable the wireless dialerEnable trouble reports Enable back-up reportingEnhanced Zone Programming Mode Input type Zone numberZone type Report codeConfirmation Enroll modeDelete zone parameters Descriptor Serial numberVoice descriptor Start by Zone Type or System Operation Device Programming Menu ModeProgramming Options Defined Start by EventUpon a Zone Type or System Operation Programming Powerline Carrier DevicesUpon Restore of a Zone List StopDevice action Powerline Carrier DeviceProgramming Device numberZone List Menu Mode Enter the 2-digit zone number Enhanced Sequential Mode00 = exit Sequential mode = copy the previous serial number entry from the buffer IA LCDelete serial number Assign zone voice descriptors Assign Zone Voice DescriptorsVoice Vocabulary Index Assign Zone Voice DescriptorCustom descriptor number Record Custom Voice DescriptorsAssign custom voice descriptors Voice Prompt Programming Keypad Functions Voice Prompt ProgrammingToenroll Second Central Station Account NumberFront Basement Back Sliding PatioPendant Type Template To Enter Expert Programming ModeEquipment required to download to a system at the premises Remote Programming/Control DownloadingRemote Programming Information Remote Programming Advisory Notes Panic Keys System OperationSecurity Codes Other Functions Volume ControlKeypad Functions Message CenterSpeaker Phone Operation LYNXR-EN Only Remote Phone Control FeatureRemote Phone Control Feature Activation Alarm Audio Verification Two-Way Voice FeatureOperator Commands If programmed Follow Me System Announcement FeaturePowerline Carrier Devices e.g. X-10 devices Exit Error Alarm DisplaysOther Displays Fault and Battery DisplaysTrouble Conditions Armed System Test Testing the SystemTest Mode Communication Overview System CommunicationReport +1/4+1 Standard +1/4+1 Expanded Contact ID Event CodesS T E M i n c l u d i n g W i r e l e s s Troubleshooting GuideO K E D E T E C T O R N T R O LRead the Instructions PLEASE, before you call Technical Support, be sure youUL Notice This is a Grade a residential system Regulatory Agency StatementsCommunication SpecificationsLYNXR-Series Security Controls ElectricalLYNXR/LYNXR24 Programming Default Tables LYNXR-EN Programming Default Tables Zone ASSIGNMENT/ALARM Report Codes for Table System Operation Start StopDevice Number Event20, 61 IndexExit Delay Serial Number Page Limitations of this Alarm System Limited Warranty System Police With‡K5963V3oŠ

LYNXR Series, LYNXR-EN specifications

The Honeywell LYNXR Series, particularly the LYNXR-EN model, represents a pinnacle of advanced security technology designed for residential and small business applications. This all-in-one wireless security system is lauded for its innovative features, ease of use, and powerful performance, making it a top choice among users seeking enhanced security solutions.

One of the standout features of the LYNXR-EN is its user-friendly touchscreen interface. The large, intuitive display allows for straightforward navigation, enabling users to arm or disarm the system, check status, and receive alerts with just a few taps. This ease of use is complemented by programmable quick access keys, which allow users to personalize their experience according to their security requirements.

Additionally, the LYNXR-EN is designed with flexibility in mind. It supports a wide range of wireless sensors and devices, facilitating comprehensive coverage for homes or small businesses. Users can integrate door and window contacts, motion detectors, glass break sensors, and more, ensuring that every entry point is monitored. The system can accommodate up to 48 wireless zones, allowing for extensive security applications without the clutter of wires.

Technologically, the LYNXR-EN leverages advanced RF technology, enhancing the reliability of communication between the panel and sensors. This feature minimizes the risk of interference and ensures consistent performance even in challenging environments. Along with this robust connectivity, the system offers dual-path communication capabilities, enabling both IP and cellular reporting. This redundancy ensures that alerts are promptly sent to the monitoring center and mobile devices, providing peace of mind to users.

Moreover, the LYNXR-EN can be easily integrated with smart home technology. It is compatible with various smart devices, allowing users to control lighting, thermostats, and other home automation features from a single platform. This integration not only enhances convenience but also optimizes energy efficiency.

The LYNXR-EN also includes a built-in battery backup, ensuring that the system remains operational during power outages. This is a crucial feature for maintaining security when it is needed most. Additionally, users can set up customizable alerts and notifications, allowing them to stay informed of any unusual activity in real-time.

In summary, the Honeywell LYNXR Series, especially the LYNXR-EN model, combines advanced technology with user-friendly design to deliver a versatile and robust security solution. Its wireless capabilities, comprehensive sensor support, smart home integration, and reliable communication make it a prominent choice in the ever-evolving realm of security systems.