Honeywell LYNXR-EN, LYNXR Series setup guide Voice Prompt Programming Keypad Functions

Page 41

Voice Prompt Programming

The LYNXR Series features a quick programming mode that allows you to program the system by responding to a series of voice prompts. The Voice Prompt Programming Guide provides you with the information required to use this feature.

Voice Prompt Programming Keypad Functions:

The keys shown below are used to navigate through the Voice Prompt Programming Feature.

1. ESCAPE/ OFF key: Used at any

 

time to exit the current menu and

 

return to the previous prompt.

1

 

2.

ADD/ AWAY

key: Used to add

 

 

sensors, or keys or save data when

 

 

entering phone or account

2

 

numbers.

 

 

3.

DELETE/ STAY key: Used to

 

delete a sensor when in the delete

Sensors Menu.

3

4. SELECT/

AUX

key: Used to

confirm a selection.

 

 

4

5.3 ↑ key: Used to scroll forward through menu choices.

 

 

ARMED

READY

OFF

1

2

3

ESCAPE

RECORD

VOLUME

PLAY

AWAY

4

5

6

ADD

LIGHTS ON

TEST

BYPASS

STAY

7

8

9

DELETE

LIGHTS OFF

CODE

CHIME

AUX

STATUS

0

#

SELECT

NO DELAY

FUNCTION

*

 

 

®

 

 

 

5

6

7

01009-021-V0

6.

6

key: Used to scroll backward

through menu choices.

7. FUNCTION/ #

key: Used to repeat a voice prompt. (This function cannot be used while entering phone or account numbers.)

Notes: (1) Keying in any new command will terminate the active voice prompt.

(2)If an irrelevant command is entered LYNXR will generate a long rejection beep and repeat the previous voice prompt.

(3)Phone numbers and account numbers can be left blank by pressing the “ADD/ AWAY key without entering any data.

(4)LYNXR automatically saves phone and account number data once all available digits are entered.

ENTERING VOICE PROMPT PROGRAMMING

1.Power-up the control and enter the Installer Code (4 1 1 2) + 8 8 8.

2.Once you have entered into the Voice Prompt Programming Mode the system will announce, “Programming, use ARROWS to scroll choices, press SELECT to accept, press ESCAPE to quit.”

3.

Press the

6

or

3

keys to scroll through the voice

 

menu and follow the instructions provided.

4.The system will announce the following options: “Add Sensors”

“Delete Sensors”

“First Central Station Phone Number” “First Central Station Account Number” “Second Central Station Phone Number” “Second Central Station Account Number” “Templates”

“Expert Programming Mode”

5.Follow the directions provided by each voice prompt to make your selections.

The FUNCTION/ # key can be used to repeat a voice

prompt, as required.

6.When you have completed each programming procedure the system will return to the Main Programming Menu.

EXITING VOICE PROMPT PROGRAMMING

1.Once you have returned to the Main Programming Menu, the system will announce, “Programming use ARROWS to scroll choices, press SELECT to accept, press ESCAPE to quit”.

2.Press ESCAPE/ OFF to exit Voice Prompt programming

mode once you have returned to the Main Programming Menu.

–41–

Image 41
Contents Ademco Lynxr Series Security Systems Recommendations For Proper Intrusion Protection Recommendations for Smoke and Heat DetectorsTable of Contents Hardwire zone System FeaturesHour backup Two-way voice communication Speaker phone operationDesktop Mounting Mounting the ControlWiring Connections Wiring ConnectionsWiring Overview Full Line Seizure Connections This System AC Power and Rechargeable Backup Battery AC Power and Backup Battery75 to 150 feet 150 to 300 feetHours minimum At least 1-hour before battery depletion Hours minimum Approximately 1-hour before battery depletionGeneral Information Installing Wireless ZonesHouse Identification Transmitter SupervisionUsing the Transmitter Sniffer Mode Transmitter Battery LifeEnter Installer code 4112 + # + Go/No Go Test ModeSetting DIP Switches on the 5800RL and 5827 Transmitters Exiting Program Mode Loading Factory DefaultsMechanics of Programming General Programming InformationType Zone Response Type DefinitionsZone Not Used Type Entry/Exit Burglary #1 Type 02 Entry/Exit Burglary #25806/5807/5808 Data Field Descriptions Defaults where applicable are Indicated in TextFields 43 Dialer ProgrammingPhone System Select Follow Me Reminder Phone NumberReport Format for Primary/Secondary Split/Dual ReportingSystem Status and Restore Report Codes Programming 59 76 System Status Report Codes Restore Report CodesRestore Report Codes Download Information 94 Enhanced Zone Programming Mode Enabling the Wireless DialerDevice Programming Menu Mode Zone Lists for Menu ModeWireless Dialer Setup Enabling the 5842 Wireless DialerEnable trouble reports Enable the wireless dialerEnable back-up reporting Response to phone line tamperEnhanced Zone Programming Mode Zone type Zone numberReport code Input typeConfirmation Enroll modeDelete zone parameters Descriptor Serial numberVoice descriptor Programming Options Defined Device Programming Menu ModeStart by Event Start by Zone Type or System OperationUpon Restore of a Zone List Programming Powerline Carrier DevicesStop Upon a Zone Type or System OperationProgramming Powerline Carrier DeviceDevice number Device actionZone List Menu Mode Enter the 2-digit zone number Enhanced Sequential Mode00 = exit Sequential mode = copy the previous serial number entry from the buffer IA LCDelete serial number Assign zone voice descriptors Assign Zone Voice DescriptorsVoice Vocabulary Index Assign Zone Voice DescriptorCustom descriptor number Record Custom Voice DescriptorsAssign custom voice descriptors Voice Prompt Programming Keypad Functions Voice Prompt ProgrammingFront Basement Back Sliding Second Central Station Account NumberPatio ToenrollPendant Type Template To Enter Expert Programming ModeEquipment required to download to a system at the premises Remote Programming/Control DownloadingRemote Programming Information Remote Programming Advisory Notes Panic Keys System OperationSecurity Codes Keypad Functions Volume ControlMessage Center Other FunctionsSpeaker Phone Operation LYNXR-EN Only Remote Phone Control FeatureRemote Phone Control Feature Activation Alarm Audio Verification Two-Way Voice FeatureOperator Commands Powerline Carrier Devices e.g. X-10 devices Follow Me System Announcement FeatureExit Error Alarm Displays If programmedOther Displays Fault and Battery DisplaysTrouble Conditions Armed System Test Testing the SystemTest Mode Communication Overview System CommunicationReport +1/4+1 Standard +1/4+1 Expanded Contact ID Event CodesS T E M i n c l u d i n g W i r e l e s s Troubleshooting GuideO K E D E T E C T O R N T R O LRead the Instructions PLEASE, before you call Technical Support, be sure youUL Notice This is a Grade a residential system Regulatory Agency StatementsLYNXR-Series Security Controls SpecificationsElectrical CommunicationLYNXR/LYNXR24 Programming Default Tables LYNXR-EN Programming Default Tables Zone ASSIGNMENT/ALARM Report Codes for Table Device Number Start StopEvent System Operation20, 61 IndexExit Delay Serial Number Page Limitations of this Alarm System Limited Warranty System Police With‡K5963V3oŠ

LYNXR Series, LYNXR-EN specifications

The Honeywell LYNXR Series, particularly the LYNXR-EN model, represents a pinnacle of advanced security technology designed for residential and small business applications. This all-in-one wireless security system is lauded for its innovative features, ease of use, and powerful performance, making it a top choice among users seeking enhanced security solutions.

One of the standout features of the LYNXR-EN is its user-friendly touchscreen interface. The large, intuitive display allows for straightforward navigation, enabling users to arm or disarm the system, check status, and receive alerts with just a few taps. This ease of use is complemented by programmable quick access keys, which allow users to personalize their experience according to their security requirements.

Additionally, the LYNXR-EN is designed with flexibility in mind. It supports a wide range of wireless sensors and devices, facilitating comprehensive coverage for homes or small businesses. Users can integrate door and window contacts, motion detectors, glass break sensors, and more, ensuring that every entry point is monitored. The system can accommodate up to 48 wireless zones, allowing for extensive security applications without the clutter of wires.

Technologically, the LYNXR-EN leverages advanced RF technology, enhancing the reliability of communication between the panel and sensors. This feature minimizes the risk of interference and ensures consistent performance even in challenging environments. Along with this robust connectivity, the system offers dual-path communication capabilities, enabling both IP and cellular reporting. This redundancy ensures that alerts are promptly sent to the monitoring center and mobile devices, providing peace of mind to users.

Moreover, the LYNXR-EN can be easily integrated with smart home technology. It is compatible with various smart devices, allowing users to control lighting, thermostats, and other home automation features from a single platform. This integration not only enhances convenience but also optimizes energy efficiency.

The LYNXR-EN also includes a built-in battery backup, ensuring that the system remains operational during power outages. This is a crucial feature for maintaining security when it is needed most. Additionally, users can set up customizable alerts and notifications, allowing them to stay informed of any unusual activity in real-time.

In summary, the Honeywell LYNXR Series, especially the LYNXR-EN model, combines advanced technology with user-friendly design to deliver a versatile and robust security solution. Its wireless capabilities, comprehensive sensor support, smart home integration, and reliable communication make it a prominent choice in the ever-evolving realm of security systems.