Honeywell LYNXR-EN, LYNXR Series setup guide Index, 20, 61

Page 65

Index

*55 Enabling the 5842 Wireless Dialer

...................................

25

*56 Enhanced Zone Programming Mode

11, 20, 24, 27

*80 Device Programming Menu Mode

24, 31, 32, 33

*81 Zone List Menu Mode

 

24, 34

*83 Enhanced Sequential Mode

24, 27, 29, 30, 35, 36, 37

*84 Assign Zone Voice Descriptors

24, 30, 38, 39

*85 Record Custom Voice Descriptors

 

24, 40

*96 Initialize Download ID And Subscriber Acct. No. For

 

Downloading

 

24

*97 Set All Program Fields To 1 Of 4 Sets Of Default Values 24

*98 Exits Programming Mode

 

24

*99 Exits Programming Mode

 

24

1.2-Volt Nickel-Metal Hydride Batteries

10

1332CN

 

9

15 Second Dialer Delay

20, 61, 62

24-Hour Audible Alarm

 

16

24-Hour Auxiliary Alarm

 

16

24-Hour Silent Alarm

 

15, 47

5800 Series Transmitters

 

11

5800RL

 

11, 13

5801

 

11

5802MN

 

11, 12

5802MN2

 

12

5804

11, 12, 35

5804BD

11, 12, 17

5804BDV

11, 12, 17

5804E

 

11, 12

5804WATCH

 

11

5816

 

11, 35

5817

 

11

5827

11, 13, 17

5828V

 

13

5842

 

25

90

 

52

A

 

 

 

AC Loss Report Code

21, 61, 62

AC Power

 

9

AC Power and Rechargeable Backup Battery

10

AC Power Loss

 

9

AC Restore Report Code

 

61, 62

AC Transformer

 

6

ADEMCO 1332/1332X10

 

9

ADEMCO Express

 

19, 60

ADEMCO Low Speed

 

19, 60

Alarm Audio Verification (AAV)/Remote Phone Control

23

Alarm Audio Verification (Two-Way Voice Feature)

50

Alarm Bell Timeout

17, 61, 62

Alarm Output

 

4

Alarm Restore Codes

 

61, 62

Alarm Restore Report Code

 

21

Alarm Sounder

 

60

Arm Away/Stay Report Code

 

61, 62

Arm AWAY/STAY Report Code

 

21

Arm–Away

 

16

Armed System Test

 

53

Arm–Stay

 

16

Assign (Or Change) A Secondary Security Code

47

Assign Custom Voice Descriptors

 

40

Assign Zone Voice Descriptors

38, 61, 62

Audible Exit Warning/Quick Exit

18, 61, 62

AUX Function

 

48

AUX Function/1-Button Paging

22, 61, 62

AUX Key

 

22

AWAY Mode

 

48

B

 

Babysitter Code

47

Back Plate

5

Backlighting

17

Backup Battery

9

Backup Reporting

18

Battery Life

12

Battery, Low

52

Bell

60

BR

11, 28

Burglary Zones

17

Busy-Standby

52

Button Transmitters

11, 12

Button Type

28

Button Zones

26, 28

Bypass Report Code

21, 61, 62

Bypass Restore Report Code

21, 61, 62

C

 

CA Message Display

51

Callback Number

23

Cancel Report Code

61, 62

Canceled Alarm

21

CC

52

Change the Master Code

47

Chime By Zone

17, 61, 62

Chime Mode

17, 48

Closing Report

18

Comm. Failure

52

Communication

4, 54

Compass Downloader

45

Confirmation of Arming Ding

18, 61, 62

Connecting AC Power and Backup Battery

9

Contact ID

54

Contact ID Event Codes

55

Contact ID Format

21, 47

Contact ID Reporting

55, 60

Contacting Technical Support

58

Custom Descriptor Number

40

Custom Voice Descriptors

24, 40

D

 

Data Encryption

45

Data Field

14

Daylight Savings Time Start/End

17, 61, 62

Daylight Savings Time Start/End Week

17

Default Master Code

61, 62

Default Tables

61, 62

Delete a Secondary Security Code

47

Delete Entire Zone List

34

Delete Zone Parameters Confirmation

29, 37

Delete Zones

34

Descriptor

30, 38

Desktop Mounting

5

Device Action

33

Device Number

33

DI Display

52

DIP Switches

11

Disable Local Sounder

7

Disarm

16, 48

Displays

52

Download Call Back Phone Number

23

Download Phone Number

61, 62

Download, Initial

45

Downloader

22, 45, 46

Duress Code

47, 63

– 65 –

Image 65
Contents Ademco Lynxr Series Security Systems Recommendations For Proper Intrusion Protection Recommendations for Smoke and Heat DetectorsTable of Contents Hardwire zone System FeaturesHour backup Two-way voice communication Speaker phone operationDesktop Mounting Mounting the ControlWiring Connections Wiring ConnectionsWiring Overview Full Line Seizure Connections This System AC Power and Rechargeable Backup Battery AC Power and Backup Battery75 to 150 feet 150 to 300 feetHours minimum At least 1-hour before battery depletion Hours minimum Approximately 1-hour before battery depletionGeneral Information Installing Wireless ZonesHouse Identification Transmitter SupervisionUsing the Transmitter Sniffer Mode Transmitter Battery LifeEnter Installer code 4112 + # + Go/No Go Test ModeSetting DIP Switches on the 5800RL and 5827 Transmitters Exiting Program Mode Loading Factory DefaultsMechanics of Programming General Programming InformationType Zone Response Type DefinitionsZone Not Used Type Entry/Exit Burglary #1 Type 02 Entry/Exit Burglary #25806/5807/5808 Data Field Descriptions Defaults where applicable are Indicated in TextFields 43 Dialer ProgrammingPhone System Select Follow Me Reminder Phone NumberReport Format for Primary/Secondary Split/Dual ReportingSystem Status and Restore Report Codes Programming 59 76 System Status Report Codes Restore Report CodesRestore Report Codes Download Information 94 Enhanced Zone Programming Mode Enabling the Wireless DialerDevice Programming Menu Mode Zone Lists for Menu ModeWireless Dialer Setup Enabling the 5842 Wireless DialerEnable trouble reports Enable the wireless dialerEnable back-up reporting Response to phone line tamperEnhanced Zone Programming Mode Zone type Zone numberReport code Input typeConfirmation Enroll modeDelete zone parameters Descriptor Serial numberVoice descriptor Programming Options Defined Device Programming Menu ModeStart by Event Start by Zone Type or System OperationUpon Restore of a Zone List Programming Powerline Carrier DevicesStop Upon a Zone Type or System OperationProgramming Powerline Carrier DeviceDevice number Device actionZone List Menu Mode Enter the 2-digit zone number Enhanced Sequential Mode00 = exit Sequential mode = copy the previous serial number entry from the buffer IA LCDelete serial number Assign zone voice descriptors Assign Zone Voice DescriptorsVoice Vocabulary Index Assign Zone Voice DescriptorCustom descriptor number Record Custom Voice DescriptorsAssign custom voice descriptors Voice Prompt Programming Keypad Functions Voice Prompt ProgrammingFront Basement Back Sliding Second Central Station Account NumberPatio ToenrollPendant Type Template To Enter Expert Programming ModeEquipment required to download to a system at the premises Remote Programming/Control DownloadingRemote Programming Information Remote Programming Advisory Notes Panic Keys System OperationSecurity Codes Keypad Functions Volume ControlMessage Center Other FunctionsSpeaker Phone Operation LYNXR-EN Only Remote Phone Control FeatureRemote Phone Control Feature Activation Alarm Audio Verification Two-Way Voice FeatureOperator Commands Powerline Carrier Devices e.g. X-10 devices Follow Me System Announcement FeatureExit Error Alarm Displays If programmedOther Displays Fault and Battery DisplaysTrouble Conditions Armed System Test Testing the SystemTest Mode Communication Overview System CommunicationReport +1/4+1 Standard +1/4+1 Expanded Contact ID Event CodesS T E M i n c l u d i n g W i r e l e s s Troubleshooting GuideO K E D E T E C T O R N T R O LRead the Instructions PLEASE, before you call Technical Support, be sure youUL Notice This is a Grade a residential system Regulatory Agency StatementsLYNXR-Series Security Controls SpecificationsElectrical CommunicationLYNXR/LYNXR24 Programming Default Tables LYNXR-EN Programming Default Tables Zone ASSIGNMENT/ALARM Report Codes for Table Device Number Start StopEvent System Operation20, 61 IndexExit Delay Serial Number Page Limitations of this Alarm System Limited Warranty System Police With‡K5963V3oŠ

LYNXR Series, LYNXR-EN specifications

The Honeywell LYNXR Series, particularly the LYNXR-EN model, represents a pinnacle of advanced security technology designed for residential and small business applications. This all-in-one wireless security system is lauded for its innovative features, ease of use, and powerful performance, making it a top choice among users seeking enhanced security solutions.

One of the standout features of the LYNXR-EN is its user-friendly touchscreen interface. The large, intuitive display allows for straightforward navigation, enabling users to arm or disarm the system, check status, and receive alerts with just a few taps. This ease of use is complemented by programmable quick access keys, which allow users to personalize their experience according to their security requirements.

Additionally, the LYNXR-EN is designed with flexibility in mind. It supports a wide range of wireless sensors and devices, facilitating comprehensive coverage for homes or small businesses. Users can integrate door and window contacts, motion detectors, glass break sensors, and more, ensuring that every entry point is monitored. The system can accommodate up to 48 wireless zones, allowing for extensive security applications without the clutter of wires.

Technologically, the LYNXR-EN leverages advanced RF technology, enhancing the reliability of communication between the panel and sensors. This feature minimizes the risk of interference and ensures consistent performance even in challenging environments. Along with this robust connectivity, the system offers dual-path communication capabilities, enabling both IP and cellular reporting. This redundancy ensures that alerts are promptly sent to the monitoring center and mobile devices, providing peace of mind to users.

Moreover, the LYNXR-EN can be easily integrated with smart home technology. It is compatible with various smart devices, allowing users to control lighting, thermostats, and other home automation features from a single platform. This integration not only enhances convenience but also optimizes energy efficiency.

The LYNXR-EN also includes a built-in battery backup, ensuring that the system remains operational during power outages. This is a crucial feature for maintaining security when it is needed most. Additionally, users can set up customizable alerts and notifications, allowing them to stay informed of any unusual activity in real-time.

In summary, the Honeywell LYNXR Series, especially the LYNXR-EN model, combines advanced technology with user-friendly design to deliver a versatile and robust security solution. Its wireless capabilities, comprehensive sensor support, smart home integration, and reliable communication make it a prominent choice in the ever-evolving realm of security systems.