Honeywell LYNXR-EN, LYNXR Series Enhanced Sequential Mode, Enter the 2-digit zone number

Page 35

83 Enhanced Sequential Mode

By using this mode, you can add, delete, or change the serial number of a transmitter in a zone, but retain all other existing data that has been programmed for that zone. Note that the 83 Enhanced Sequential mode requires that all zone information must first be entered using the 56 Enhanced Zone Programming mode for all zones below zone number 26 (4 button key area).

Note: Any zone which already has a serial number learned in will not be accessible in 83 Enhanced Sequential mode!

Certain button-type transmitters have more than one button (e.g., 5804). Note that each button must be assigned to a different zone. Similarly, the 5816 Transmitter has contact terminals and a reed switch for use with a magnet. If using both, each must also be assigned to a different zone.

This means that the procedures that follow must be repeated for each button-type zone below zone number 26 or contact on the transmitter. Four zone button-type devices are held in zones 26 and above. They will be started on boundaries of zones 26, 30, 34, and 38. These four zone button-type devices will have the option to have all information entered in this field. One entry will set the loop number, report code, zone type, and input device type for all 4 buttons, and a second entry will enter one serial number into four zones.

Note: Use this mode only after all other zone information has been programmed, including transmitter loop numbers except for button-type zones over zone number 26. The panel will stop at zones 26, 30, 34 and 38 and zone data can be entered as a default here.

Enter Serial Number Sequential mode by pressing 83. The prompts for 83 are as follows:

A01

1A

1b F

Zone Number ------------------------------------

for entering the zone number to be programmed

Enroll Mode --------------------------------------

Selects method of serial number or viewing

Enroll Serial Number -------------------------

for entering transmitter serial numbers

Delete Serial Number-------------------------

for deleting existing serial numbers

The following explains these prompts in detail. The left two columns identify the prompts and list the available entries. The right-most column provides a further explanation of the entries.

Notes: (1) Entry of a number other than one specified will give unpredictable results.

(2)In Enhanced Sequential Mode, 4 button type keys will always be enrolled simultaneously. They will be stopped at the 4 button boundaries of 26, 30, 34 and 38, provided the zone is free of a serial number. If the first zone of the key has a serial number enrolled, the remaining keys cannot be programmed in sequential mode. In addition, if the zone has not been set up (duplicate loop, missing zone type, etc.) only entries 0 (skip to the next zone) and 4 (copy the key template) will be allowed.

(3)You may find it convenient to adjust the volume setting before entering the Programming Mode. This will allow you to clearly hear feedback announcements or system beeps.

A 0I

Zone number

Enter the 2-digit zone number.

[] = continue; system searches for zones not yet entered (for zones 2 through 25 a zone type must be entered), then advances to ENROLL SERIAL NUMBER prompt “1b”

00 = exit Sequential mode

Enter the 2-digit zone number of the first transmitter to have its serial number entered. The system will announce the Voice Descriptor for the selected zone number, if it is programmed.

Press [] to continue. Starting with this zone number, the system will search for the first transmitter that has all of the following attributes pre-programmed in 56 ENHANCED ZONE PROGRAMMING:

a)Make sure that the appropriate input type was selected in 56 (RF, UR, or BR programmed)

b)Make sure that the appropriate loop number was selected in 56.

c)No serial number programmed

d)Zone type

If the first zone number entered does not have one or more of the above attributes, the system will search its database for the first zone that does, and will display it at the enroll SERIAL NUMBER prompt (1b). Pressing 00 exits mode, upon which the prompt “83” blinks, indicating the mode is inactive.

Note: Two exceptions to the requirement above exist for keys. Four zone button type devices (zone numbers 26, 30, 34, and 38) will be stopped only if there are no serial numbers enrolled in all 4 zones of the key, regardless of the attributes that have been entered. In addition, zone types are not required to be present. In this case, 1A, Option 4 must be selected prior to “Learn”.

–35–

Image 35
Contents Ademco Lynxr Series Security Systems Recommendations For Proper Intrusion Protection Recommendations for Smoke and Heat DetectorsTable of Contents Two-way voice communication Speaker phone operation System FeaturesHardwire zone Hour backupDesktop Mounting Mounting the ControlWiring Connections Wiring ConnectionsWiring Overview Full Line Seizure Connections This System 150 to 300 feet AC Power and Backup BatteryAC Power and Rechargeable Backup Battery 75 to 150 feetHours minimum At least 1-hour before battery depletion Hours minimum Approximately 1-hour before battery depletionTransmitter Supervision Installing Wireless ZonesGeneral Information House IdentificationGo/No Go Test Mode Transmitter Battery LifeUsing the Transmitter Sniffer Mode Enter Installer code 4112 + # +Setting DIP Switches on the 5800RL and 5827 Transmitters General Programming Information Loading Factory DefaultsExiting Program Mode Mechanics of ProgrammingType 02 Entry/Exit Burglary #2 Zone Response Type DefinitionsType Zone Not Used Type Entry/Exit Burglary #15806/5807/5808 Data Field Descriptions Defaults where applicable are Indicated in TextFields 43 Dialer ProgrammingSplit/Dual Reporting Follow Me Reminder Phone NumberPhone System Select Report Format for Primary/SecondarySystem Status and Restore Report Codes Programming 59 76 System Status Report Codes Restore Report CodesRestore Report Codes Download Information 94 Zone Lists for Menu Mode Enabling the Wireless DialerEnhanced Zone Programming Mode Device Programming Menu ModeWireless Dialer Setup Enabling the 5842 Wireless DialerResponse to phone line tamper Enable the wireless dialerEnable trouble reports Enable back-up reportingEnhanced Zone Programming Mode Input type Zone numberZone type Report codeConfirmation Enroll modeDelete zone parameters Descriptor Serial numberVoice descriptor Start by Zone Type or System Operation Device Programming Menu ModeProgramming Options Defined Start by EventUpon a Zone Type or System Operation Programming Powerline Carrier DevicesUpon Restore of a Zone List StopDevice action Powerline Carrier DeviceProgramming Device numberZone List Menu Mode Enter the 2-digit zone number Enhanced Sequential Mode00 = exit Sequential mode = copy the previous serial number entry from the buffer IA LCDelete serial number Assign zone voice descriptors Assign Zone Voice DescriptorsVoice Vocabulary Index Assign Zone Voice DescriptorCustom descriptor number Record Custom Voice DescriptorsAssign custom voice descriptors Voice Prompt Programming Keypad Functions Voice Prompt ProgrammingToenroll Second Central Station Account NumberFront Basement Back Sliding PatioPendant Type Template To Enter Expert Programming ModeEquipment required to download to a system at the premises Remote Programming/Control DownloadingRemote Programming Information Remote Programming Advisory Notes Panic Keys System OperationSecurity Codes Other Functions Volume ControlKeypad Functions Message CenterSpeaker Phone Operation LYNXR-EN Only Remote Phone Control FeatureRemote Phone Control Feature Activation Alarm Audio Verification Two-Way Voice FeatureOperator Commands If programmed Follow Me System Announcement FeaturePowerline Carrier Devices e.g. X-10 devices Exit Error Alarm DisplaysOther Displays Fault and Battery DisplaysTrouble Conditions Armed System Test Testing the SystemTest Mode Communication Overview System CommunicationReport +1/4+1 Standard +1/4+1 Expanded Contact ID Event CodesS T E M i n c l u d i n g W i r e l e s s Troubleshooting GuideO K E D E T E C T O R N T R O LRead the Instructions PLEASE, before you call Technical Support, be sure youUL Notice This is a Grade a residential system Regulatory Agency StatementsCommunication SpecificationsLYNXR-Series Security Controls ElectricalLYNXR/LYNXR24 Programming Default Tables LYNXR-EN Programming Default Tables Zone ASSIGNMENT/ALARM Report Codes for Table System Operation Start StopDevice Number Event20, 61 IndexExit Delay Serial Number Page Limitations of this Alarm System Limited Warranty System Police With‡K5963V3oŠ

LYNXR Series, LYNXR-EN specifications

The Honeywell LYNXR Series, particularly the LYNXR-EN model, represents a pinnacle of advanced security technology designed for residential and small business applications. This all-in-one wireless security system is lauded for its innovative features, ease of use, and powerful performance, making it a top choice among users seeking enhanced security solutions.

One of the standout features of the LYNXR-EN is its user-friendly touchscreen interface. The large, intuitive display allows for straightforward navigation, enabling users to arm or disarm the system, check status, and receive alerts with just a few taps. This ease of use is complemented by programmable quick access keys, which allow users to personalize their experience according to their security requirements.

Additionally, the LYNXR-EN is designed with flexibility in mind. It supports a wide range of wireless sensors and devices, facilitating comprehensive coverage for homes or small businesses. Users can integrate door and window contacts, motion detectors, glass break sensors, and more, ensuring that every entry point is monitored. The system can accommodate up to 48 wireless zones, allowing for extensive security applications without the clutter of wires.

Technologically, the LYNXR-EN leverages advanced RF technology, enhancing the reliability of communication between the panel and sensors. This feature minimizes the risk of interference and ensures consistent performance even in challenging environments. Along with this robust connectivity, the system offers dual-path communication capabilities, enabling both IP and cellular reporting. This redundancy ensures that alerts are promptly sent to the monitoring center and mobile devices, providing peace of mind to users.

Moreover, the LYNXR-EN can be easily integrated with smart home technology. It is compatible with various smart devices, allowing users to control lighting, thermostats, and other home automation features from a single platform. This integration not only enhances convenience but also optimizes energy efficiency.

The LYNXR-EN also includes a built-in battery backup, ensuring that the system remains operational during power outages. This is a crucial feature for maintaining security when it is needed most. Additionally, users can set up customizable alerts and notifications, allowing them to stay informed of any unusual activity in real-time.

In summary, the Honeywell LYNXR Series, especially the LYNXR-EN model, combines advanced technology with user-friendly design to deliver a versatile and robust security solution. Its wireless capabilities, comprehensive sensor support, smart home integration, and reliable communication make it a prominent choice in the ever-evolving realm of security systems.