System Features

 

LYNXR and LYNXR-EN are not intended for UL985 Household Fire applications unless a 24-hour backup

UL

battery (P/N LYNXRCHKIT-HC) is installed.

Powerline Carrier Devices are not UL Listed for fire or burglary functions and are intended for home

 

 

automation.

 

 

The LYNXR-Series controls are self-contained, rechargeable wireless control/communicators that feature easy installation and usage. A built-in speaker provides voice annunciation of system status along with voice descriptors of each zone (LYNXR-EN if programmed). The following illustration highlights the main features of this system.

ZONES and DEVICES

1 hardwire zone

Up to 24 wireless zones (5800 Series Transmitters)

Up to 16 wireless button zones

Up to 8 Powerline Carrier Devices

Supports wireless keypads

FEATURES

Real-time Clock display and Fixed-Word display

Message Center (for user recorded messages)

Voice announcement of system and zone status

Voice chime

Alarm Clock

Reminder

X-10 Scheduling

Latch Key Reports

Automatic Stay Arming

Remote Phone Control

“Follow Me” Reminder and System Announcements

SYSTEM POWER

Primary Power: Ademco 1332/1332X10 Plug-in Transformer, 110VAC to 9VAC, 15VA output (1332CN in Canada)

Backup battery: Six 1.2V rechargeable nickel-metal hydride batteries.

8 USER CODES

Installer code

Master code

5 Secondary codes

Duress code

3 Panic functions

COMMUNICATION

ESCAPE RECORDVOLUMEARMEDREADY

OFF1 2 PLAY3

DELETEADDW Y LIGHTSLIGHTS4OFFONCODETEST 5 CHIMEBYPASS6

Ademco Low Speed

Sescoa/Radionics

Ademco Express

Ademco Contact ID

Paging feature

AY

7

8

9

SELECTAUX STATUSNODELAY0FUNCTION#

ALARM OUTPUT

Built-in sounder

Piezo output (30mA max.)

Bell output (120mA max.)

Steady output for burglary/panic

Temporal pulse output for fire alarms

Long Range Radio/Alarm audio verification

PROGRAMMING

Options stored in EEROM

Can be uploaded, downloaded or controlled via IBM-compatible computer using Compass downloader software and specified HAYES modem

Voice Prompt programming mode

OTHER FEATURES

Exit error feature (detects difference between an actual alarm and exit alarm caused by leaving a door open after the exit delay expires)

Event log stores up to 84 events

Macro/ 1-button paging

RF Jam Detection

Remote phone control

Compatible with 5842 Wireless Dialer

Compatible with encrypted (high-security) devices

SPECIAL FEATURES

LYNXR24

24-hour backup

LYNXR-EN

Two-way voice communication

Speaker phone operation

–4–

Image 4
Contents Ademco Lynxr Series Security Systems Recommendations for Smoke and Heat Detectors Recommendations For Proper Intrusion ProtectionTable of Contents System Features Hardwire zoneHour backup Two-way voice communication Speaker phone operationMounting the Control Desktop MountingWiring Overview Wiring ConnectionsWiring Connections Full Line Seizure Connections This System AC Power and Backup Battery AC Power and Rechargeable Backup Battery75 to 150 feet 150 to 300 feetHours minimum Approximately 1-hour before battery depletion Hours minimum At least 1-hour before battery depletionInstalling Wireless Zones General InformationHouse Identification Transmitter SupervisionTransmitter Battery Life Using the Transmitter Sniffer ModeEnter Installer code 4112 + # + Go/No Go Test ModeSetting DIP Switches on the 5800RL and 5827 Transmitters Loading Factory Defaults Exiting Program ModeMechanics of Programming General Programming InformationZone Response Type Definitions TypeZone Not Used Type Entry/Exit Burglary #1 Type 02 Entry/Exit Burglary #25806/5807/5808 Defaults where applicable are Indicated in Text Data Field DescriptionsDialer Programming Fields 43Follow Me Reminder Phone Number Phone System SelectReport Format for Primary/Secondary Split/Dual ReportingSystem Status and Restore Report Codes Programming 59 76 Restore Report Codes System Status Report CodesRestore Report Codes Download Information 94 Enabling the Wireless Dialer Enhanced Zone Programming ModeDevice Programming Menu Mode Zone Lists for Menu ModeEnabling the 5842 Wireless Dialer Wireless Dialer SetupEnable the wireless dialer Enable trouble reportsEnable back-up reporting Response to phone line tamperEnhanced Zone Programming Mode Zone number Zone typeReport code Input typeDelete zone parameters Enroll modeConfirmation Voice descriptor Serial numberDescriptor Device Programming Menu Mode Programming Options DefinedStart by Event Start by Zone Type or System OperationProgramming Powerline Carrier Devices Upon Restore of a Zone ListStop Upon a Zone Type or System OperationPowerline Carrier Device ProgrammingDevice number Device actionZone List Menu Mode 00 = exit Sequential mode Enhanced Sequential ModeEnter the 2-digit zone number IA LC = copy the previous serial number entry from the bufferDelete serial number Assign Zone Voice Descriptors Assign zone voice descriptorsAssign Zone Voice Descriptor Voice Vocabulary IndexAssign custom voice descriptors Record Custom Voice DescriptorsCustom descriptor number Voice Prompt Programming Voice Prompt Programming Keypad FunctionsSecond Central Station Account Number Front Basement Back SlidingPatio ToenrollPendant Type To Enter Expert Programming Mode TemplateRemote Programming Information Remote Programming/Control DownloadingEquipment required to download to a system at the premises Remote Programming Advisory Notes Security Codes System OperationPanic Keys Volume Control Keypad FunctionsMessage Center Other FunctionsRemote Phone Control Feature Remote Phone Control FeatureSpeaker Phone Operation LYNXR-EN Only Operator Commands Alarm Audio Verification Two-Way Voice FeatureActivation Follow Me System Announcement Feature Powerline Carrier Devices e.g. X-10 devicesExit Error Alarm Displays If programmedTrouble Conditions Fault and Battery DisplaysOther Displays Test Mode Testing the SystemArmed System Test System Communication Communication OverviewContact ID Event Codes Report +1/4+1 Standard +1/4+1 ExpandedTroubleshooting Guide S T E M i n c l u d i n g W i r e l e s sN T R O L O K E D E T E C T O RPLEASE, before you call Technical Support, be sure you Read the InstructionsRegulatory Agency Statements UL Notice This is a Grade a residential systemSpecifications LYNXR-Series Security ControlsElectrical CommunicationLYNXR/LYNXR24 Programming Default Tables LYNXR-EN Programming Default Tables Zone ASSIGNMENT/ALARM Report Codes for Table Start Stop Device NumberEvent System OperationIndex 20, 61Exit Delay Serial Number Page Limitations of this Alarm System Limited Warranty Police With System‡K5963V3oŠ

LYNXR Series, LYNXR-EN specifications

The Honeywell LYNXR Series, particularly the LYNXR-EN model, represents a pinnacle of advanced security technology designed for residential and small business applications. This all-in-one wireless security system is lauded for its innovative features, ease of use, and powerful performance, making it a top choice among users seeking enhanced security solutions.

One of the standout features of the LYNXR-EN is its user-friendly touchscreen interface. The large, intuitive display allows for straightforward navigation, enabling users to arm or disarm the system, check status, and receive alerts with just a few taps. This ease of use is complemented by programmable quick access keys, which allow users to personalize their experience according to their security requirements.

Additionally, the LYNXR-EN is designed with flexibility in mind. It supports a wide range of wireless sensors and devices, facilitating comprehensive coverage for homes or small businesses. Users can integrate door and window contacts, motion detectors, glass break sensors, and more, ensuring that every entry point is monitored. The system can accommodate up to 48 wireless zones, allowing for extensive security applications without the clutter of wires.

Technologically, the LYNXR-EN leverages advanced RF technology, enhancing the reliability of communication between the panel and sensors. This feature minimizes the risk of interference and ensures consistent performance even in challenging environments. Along with this robust connectivity, the system offers dual-path communication capabilities, enabling both IP and cellular reporting. This redundancy ensures that alerts are promptly sent to the monitoring center and mobile devices, providing peace of mind to users.

Moreover, the LYNXR-EN can be easily integrated with smart home technology. It is compatible with various smart devices, allowing users to control lighting, thermostats, and other home automation features from a single platform. This integration not only enhances convenience but also optimizes energy efficiency.

The LYNXR-EN also includes a built-in battery backup, ensuring that the system remains operational during power outages. This is a crucial feature for maintaining security when it is needed most. Additionally, users can set up customizable alerts and notifications, allowing them to stay informed of any unusual activity in real-time.

In summary, the Honeywell LYNXR Series, especially the LYNXR-EN model, combines advanced technology with user-friendly design to deliver a versatile and robust security solution. Its wireless capabilities, comprehensive sensor support, smart home integration, and reliable communication make it a prominent choice in the ever-evolving realm of security systems.