Honeywell LYNXR-EN, LYNXR Series setup guide Delete serial number

Page 37

83 Enhanced Sequential Mode

 

 

 

 

Serial number

This prompt can be used to enroll the transmitter serial number via

 

Ib

 

 

zz

 

Enter transmitter’s 7- digit serial number via RF

RF transmission or manually. If using the RF Learning Mode there

 

 

is no need to manually enter a serial number. Proceed directly to RF

 

 

 

 

learning or manually.

Learning. Upon entering the Serial Number mode, the Zone

 

 

 

 

 

 

 

[#] = return to (1A) prompt and reject whatever

Descriptors will be announced.

 

 

 

 

serial number entries have been made.

Note: BR type devices can be enrolled only by transmission from BR

 

Ib

 

 

[] = return to (1A) prompt (if a valid serial

devices. Likewise, UR and RF devices can only be enrolled by

 

 

 

number has been enrolled, “L” is displayed

transmission from a UR or RF device

 

 

 

 

 

 

 

 

and the serial number will be copied into

RF Learning - Two (2) transmissions (2 key depressions) at least

 

 

 

 

 

 

 

EEROM and the last serial entered buffer.

five seconds apart, will be required for BR type or four (4)

 

 

 

 

 

transmissions (fault, restore and fault, restore) for UR or RF type. If

 

 

 

 

Note: For zones 26, 30, 34 and 38 only BR type

the learned serial number has a different loop number than that

 

 

 

 

entered in 56 the system will announce the Voice Descriptor, if it

 

 

 

 

devices can be used.

 

 

 

 

is programmed, followed by two beeps and will return to Prompt (1A)

 

 

 

 

 

 

 

 

 

 

and “L” will be displayed.

 

 

 

 

 

If the loop number captured by RF transmission and that entered in

 

 

 

 

 

56 mode match, the system will announce the Voice Descriptor, if it

 

 

 

 

 

is programmed, followed by three beeps and return to Prompt (1A)

 

 

 

 

 

and “LC” will be displayed. No additional transmissions are needed

 

 

 

 

 

for confirmation.

 

 

 

 

 

Manual Entry - Enter the 7-digit serial number printed on the

 

 

 

 

 

transmitter. If you enter an incorrect digit, press the [#] key to

 

 

 

 

 

backup to prompt (1A) and start over. When all 7 digits are entered,

 

 

 

 

 

press the [] key. If less than 7 digits are entered, the keypad will

 

 

 

 

 

emit a single long beep and return to the (1A) prompt without

 

 

 

 

 

displaying the “L”.

 

 

 

 

 

If more than 7 digits have been entered, the first 6 digits will be

 

 

 

 

 

saved along with the last digit that was entered (entering 123456789

 

 

 

 

 

yields the serial number 1234569).

 

 

 

 

 

Note: If 52 seconds pass and no entry has been made, the system

 

 

 

 

 

returns to prompt (1A).

 

 

 

 

 

 

 

 

 

 

Delete serial number

This function deletes only the serial number.

 

F

 

 

 

 

0 = discard the delete request

Entering a “9” at prompt (1A). Confirmation of the delete request will

 

 

 

1 = confirm requested delete

cause deletion of the serial number pertaining to the zone being

 

 

 

 

Note: Entering a “9” at prompt (1A) will cause the

programmed.

 

 

 

 

 

 

 

 

 

panel to return to prompt (1A) regardless of

 

 

 

 

 

the confirmation answer.

 

 

 

 

 

 

 

Note: In Enhanced Sequential Learn Mode, 4 button type keys will always be learned simultaneously. They will be stopped at the 4 button boundaries of 26, 30, 34 and 38, provided the zone is free of a serial number. If the first zone of the key has a serial number learned, the remaining keys cannot be programmed in sequential learn mode. In addition, if the zone has not been set up (duplicate loop, missing zone type, etc.) only entries 0 (skip to the next zone) and 4 (copy the key template) will be allowed.

–37–

Image 37
Contents Ademco Lynxr Series Security Systems Recommendations For Proper Intrusion Protection Recommendations for Smoke and Heat DetectorsTable of Contents Hardwire zone System FeaturesHour backup Two-way voice communication Speaker phone operationDesktop Mounting Mounting the ControlWiring Overview Wiring ConnectionsWiring Connections Full Line Seizure Connections This System AC Power and Rechargeable Backup Battery AC Power and Backup Battery75 to 150 feet 150 to 300 feetHours minimum At least 1-hour before battery depletion Hours minimum Approximately 1-hour before battery depletionGeneral Information Installing Wireless ZonesHouse Identification Transmitter SupervisionUsing the Transmitter Sniffer Mode Transmitter Battery LifeEnter Installer code 4112 + # + Go/No Go Test ModeSetting DIP Switches on the 5800RL and 5827 Transmitters Exiting Program Mode Loading Factory DefaultsMechanics of Programming General Programming InformationType Zone Response Type DefinitionsZone Not Used Type Entry/Exit Burglary #1 Type 02 Entry/Exit Burglary #25806/5807/5808 Data Field Descriptions Defaults where applicable are Indicated in TextFields 43 Dialer ProgrammingPhone System Select Follow Me Reminder Phone NumberReport Format for Primary/Secondary Split/Dual ReportingSystem Status and Restore Report Codes Programming 59 76 System Status Report Codes Restore Report CodesRestore Report Codes Download Information 94 Enhanced Zone Programming Mode Enabling the Wireless DialerDevice Programming Menu Mode Zone Lists for Menu ModeWireless Dialer Setup Enabling the 5842 Wireless DialerEnable trouble reports Enable the wireless dialerEnable back-up reporting Response to phone line tamperEnhanced Zone Programming Mode Zone type Zone numberReport code Input typeDelete zone parameters Enroll modeConfirmation Voice descriptor Serial numberDescriptor Programming Options Defined Device Programming Menu ModeStart by Event Start by Zone Type or System OperationUpon Restore of a Zone List Programming Powerline Carrier DevicesStop Upon a Zone Type or System OperationProgramming Powerline Carrier DeviceDevice number Device actionZone List Menu Mode 00 = exit Sequential mode Enhanced Sequential ModeEnter the 2-digit zone number = copy the previous serial number entry from the buffer IA LCDelete serial number Assign zone voice descriptors Assign Zone Voice DescriptorsVoice Vocabulary Index Assign Zone Voice DescriptorAssign custom voice descriptors Record Custom Voice DescriptorsCustom descriptor number Voice Prompt Programming Keypad Functions Voice Prompt ProgrammingFront Basement Back Sliding Second Central Station Account NumberPatio ToenrollPendant Type Template To Enter Expert Programming ModeRemote Programming Information Remote Programming/Control DownloadingEquipment required to download to a system at the premises Remote Programming Advisory Notes Security Codes System OperationPanic Keys Keypad Functions Volume ControlMessage Center Other FunctionsRemote Phone Control Feature Remote Phone Control FeatureSpeaker Phone Operation LYNXR-EN Only Operator Commands Alarm Audio Verification Two-Way Voice FeatureActivation Powerline Carrier Devices e.g. X-10 devices Follow Me System Announcement FeatureExit Error Alarm Displays If programmedTrouble Conditions Fault and Battery DisplaysOther Displays Test Mode Testing the SystemArmed System Test Communication Overview System CommunicationReport +1/4+1 Standard +1/4+1 Expanded Contact ID Event CodesS T E M i n c l u d i n g W i r e l e s s Troubleshooting GuideO K E D E T E C T O R N T R O LRead the Instructions PLEASE, before you call Technical Support, be sure youUL Notice This is a Grade a residential system Regulatory Agency StatementsLYNXR-Series Security Controls SpecificationsElectrical CommunicationLYNXR/LYNXR24 Programming Default Tables LYNXR-EN Programming Default Tables Zone ASSIGNMENT/ALARM Report Codes for Table Device Number Start StopEvent System Operation20, 61 IndexExit Delay Serial Number Page Limitations of this Alarm System Limited Warranty System Police With‡K5963V3oŠ

LYNXR Series, LYNXR-EN specifications

The Honeywell LYNXR Series, particularly the LYNXR-EN model, represents a pinnacle of advanced security technology designed for residential and small business applications. This all-in-one wireless security system is lauded for its innovative features, ease of use, and powerful performance, making it a top choice among users seeking enhanced security solutions.

One of the standout features of the LYNXR-EN is its user-friendly touchscreen interface. The large, intuitive display allows for straightforward navigation, enabling users to arm or disarm the system, check status, and receive alerts with just a few taps. This ease of use is complemented by programmable quick access keys, which allow users to personalize their experience according to their security requirements.

Additionally, the LYNXR-EN is designed with flexibility in mind. It supports a wide range of wireless sensors and devices, facilitating comprehensive coverage for homes or small businesses. Users can integrate door and window contacts, motion detectors, glass break sensors, and more, ensuring that every entry point is monitored. The system can accommodate up to 48 wireless zones, allowing for extensive security applications without the clutter of wires.

Technologically, the LYNXR-EN leverages advanced RF technology, enhancing the reliability of communication between the panel and sensors. This feature minimizes the risk of interference and ensures consistent performance even in challenging environments. Along with this robust connectivity, the system offers dual-path communication capabilities, enabling both IP and cellular reporting. This redundancy ensures that alerts are promptly sent to the monitoring center and mobile devices, providing peace of mind to users.

Moreover, the LYNXR-EN can be easily integrated with smart home technology. It is compatible with various smart devices, allowing users to control lighting, thermostats, and other home automation features from a single platform. This integration not only enhances convenience but also optimizes energy efficiency.

The LYNXR-EN also includes a built-in battery backup, ensuring that the system remains operational during power outages. This is a crucial feature for maintaining security when it is needed most. Additionally, users can set up customizable alerts and notifications, allowing them to stay informed of any unusual activity in real-time.

In summary, the Honeywell LYNXR Series, especially the LYNXR-EN model, combines advanced technology with user-friendly design to deliver a versatile and robust security solution. Its wireless capabilities, comprehensive sensor support, smart home integration, and reliable communication make it a prominent choice in the ever-evolving realm of security systems.