Honeywell LYNXR-EN, LYNXR Series setup guide LYNXR/LYNXR24 Programming Default Tables

Page 61

LYNXR/LYNXR24 PROGRAMMING DEFAULT TABLES

(boldface indicates defaults that differ between tables)

Function

Table 1

Table 2

Table 3

Table 4

*20

Installer code

4112

4112

4112

4112

*21

Quick arm enable

1

1

1

1

*22

Keypad backlight timeout

0

0

0

0

*23

Forced bypass

0

0

0

0

*24

RF house ID code

0,0

0,0

0,0

0,0

*25

Powerline carrier device house code

0

0

0

0

*26

Chime-by-zone

0

0

0

0

*27

Real-time clock display

1

1

1

1

*29

Daylight saving time start/end month

4,10

4,10

4,10

4,10

*30

Daylight saving time start/end weekend

1,5

1,5

1,5

1,5

*31

Single alarm sounding per zone

0

0

0

0

*32

Fire sounder timeout

0

0

0

0

*33

Alarm bell timeout

1

1

1

1

*34

Exit delay

7,0

6,0

7,0

7,0

*35 Entry delay 1 (zone type 01)

3,0

4,5

3,0

3,0

*36

Entry delay 2 (zone type 02)

6,0

6,0

6,0

6,0

*37 Audible exit warning/quick exit

1,1

0,1

1,1

1,1

*38

Confirmation of arming ding

0

0

0

0

*39

Power up in previous state

1

1

1

1

*40

PABX access code

---

---

---

---

*41

Primary phone number

---

---

---

---

*42

Secondary phone number

---

---

---

---

*43

Primary subscriber account number

15,15,15,15

15,15,15,15

15,15,15,15

15,15,15,15

*44

Secondary subscriber account number

---

---

---

---

*46

“Follow Me Reminder” Phone Number

---

---

---

---

*47

Phone system select

1

1

1

1

*48

Report format

7,7

7,7

7,7

7,7

*49

Split/dual reporting

0

0

0

9

*50 15 second dialer delay (burglary)

0

1

0

0

*51

Periodic test report

0

3

0

0

*52

First test report offset

2

2

2

2

*53

Sescoa/radionics select

0

0

0

0

*54

Lack of usage notification

0

0

0

0

*55

Wireless Dialer

0, 0, 0, 0

0, 0, 0, 0

0, 0, 0, 0

0, 0, 0, 0

*56

Enhanced Zone programming

See *56 table

See *56 table

See *56 table

See *56 table

*58

RF jam detection

0

0

0

0

*59 Exit error report code

1

0

1

1

*60

Trouble report code

1,0

1,0

1,0

1,0

*61

Bypass report code

0,0

0,0

0,0

0,0

*62

AC loss report code

0,0

0,0

0,0

0,0

*63

Low battery Report code

1,0

1,0

1,0

1,0

*64

Test report code

1,0

1,0

1,0

1,0

*65

Open report code

0

0

0

0

*66

Arm away/stay report code

0,0

0,0

0,0

0,0

*67

RF transmitter low battery report code

1,0

1,0

1,0

1,0

*68

Cancel report code

1,0

1,0

1,0

1,0

*70

Alarm restore codes

1

1

1

1

*71

Trouble restore report code

1,0

1,0

1,0

1,0

*72

Bypass restore report code

0,0

0,0

0,0

0,0

*73

AC restore report code

0,0

0,0

0,0

0,0

*74

Low battery restore report code

1,0

1,0

1,0

1,0

*75

RF transmitter low battery restore report code

1,0

1,0

1,0

1,0

*76 Test restore report code

0,0

1,0

0,0

0,0

*80

Powerline Carrier Devices

See *80 table

See *80 table

See *80 table

See *80 table

*81 Zone lists for devices

See *81 table

See *81 table

See *81 table

See *81 table

*84

Assign zone voice descriptors

 

Refer to *84

Programming

 

*87 Auxiliary Function/ 1-button paging

0

1

0

1

*88

Pager characters

---

---

---

---

*89

Event log 80% full report code

0,0

0,0

0,0

0,0

*90

Event logging

3

15

3

3

*91

LRR/AAV Trigger/Remote Phone Control

2

2

2

2

*92

Number of reports in armed period

0

0

0

0

*93

Flexible call back

0

0

0

0

*94

Download phone number

---

---

---

---

*95

Ring detect count for downloading/remote phone control

15

15

15

15

Default Master Code

1,2,3,4

1,2,3,4

1,2,3,4

1,2,3,4

Default Duress Code

---

---

---

---

By activating *96, Field 43, and 44 will be changed to 15, 15, 15, 15.

 

 

 

 

– 61 –

Image 61
Contents Ademco Lynxr Series Security Systems Recommendations For Proper Intrusion Protection Recommendations for Smoke and Heat DetectorsTable of Contents Hardwire zone System FeaturesHour backup Two-way voice communication Speaker phone operationDesktop Mounting Mounting the ControlWiring Overview Wiring ConnectionsWiring Connections Full Line Seizure Connections This System AC Power and Rechargeable Backup Battery AC Power and Backup Battery75 to 150 feet 150 to 300 feetHours minimum At least 1-hour before battery depletion Hours minimum Approximately 1-hour before battery depletionGeneral Information Installing Wireless ZonesHouse Identification Transmitter SupervisionUsing the Transmitter Sniffer Mode Transmitter Battery LifeEnter Installer code 4112 + # + Go/No Go Test ModeSetting DIP Switches on the 5800RL and 5827 Transmitters Exiting Program Mode Loading Factory DefaultsMechanics of Programming General Programming InformationType Zone Response Type DefinitionsZone Not Used Type Entry/Exit Burglary #1 Type 02 Entry/Exit Burglary #25806/5807/5808 Data Field Descriptions Defaults where applicable are Indicated in TextFields 43 Dialer ProgrammingPhone System Select Follow Me Reminder Phone NumberReport Format for Primary/Secondary Split/Dual ReportingSystem Status and Restore Report Codes Programming 59 76 System Status Report Codes Restore Report CodesRestore Report Codes Download Information 94 Enhanced Zone Programming Mode Enabling the Wireless DialerDevice Programming Menu Mode Zone Lists for Menu ModeWireless Dialer Setup Enabling the 5842 Wireless DialerEnable trouble reports Enable the wireless dialerEnable back-up reporting Response to phone line tamperEnhanced Zone Programming Mode Zone type Zone numberReport code Input typeDelete zone parameters Enroll modeConfirmation Voice descriptor Serial numberDescriptor Programming Options Defined Device Programming Menu ModeStart by Event Start by Zone Type or System OperationUpon Restore of a Zone List Programming Powerline Carrier DevicesStop Upon a Zone Type or System OperationProgramming Powerline Carrier DeviceDevice number Device actionZone List Menu Mode 00 = exit Sequential mode Enhanced Sequential ModeEnter the 2-digit zone number = copy the previous serial number entry from the buffer IA LCDelete serial number Assign zone voice descriptors Assign Zone Voice DescriptorsVoice Vocabulary Index Assign Zone Voice DescriptorAssign custom voice descriptors Record Custom Voice DescriptorsCustom descriptor number Voice Prompt Programming Keypad Functions Voice Prompt ProgrammingFront Basement Back Sliding Second Central Station Account NumberPatio ToenrollPendant Type Template To Enter Expert Programming ModeRemote Programming Information Remote Programming/Control DownloadingEquipment required to download to a system at the premises Remote Programming Advisory Notes Security Codes System OperationPanic Keys Keypad Functions Volume ControlMessage Center Other FunctionsRemote Phone Control Feature Remote Phone Control FeatureSpeaker Phone Operation LYNXR-EN Only Operator Commands Alarm Audio Verification Two-Way Voice FeatureActivation Powerline Carrier Devices e.g. X-10 devices Follow Me System Announcement FeatureExit Error Alarm Displays If programmedTrouble Conditions Fault and Battery DisplaysOther Displays Test Mode Testing the SystemArmed System Test Communication Overview System CommunicationReport +1/4+1 Standard +1/4+1 Expanded Contact ID Event CodesS T E M i n c l u d i n g W i r e l e s s Troubleshooting GuideO K E D E T E C T O R N T R O LRead the Instructions PLEASE, before you call Technical Support, be sure youUL Notice This is a Grade a residential system Regulatory Agency StatementsLYNXR-Series Security Controls SpecificationsElectrical CommunicationLYNXR/LYNXR24 Programming Default Tables LYNXR-EN Programming Default Tables Zone ASSIGNMENT/ALARM Report Codes for Table Device Number Start StopEvent System Operation20, 61 IndexExit Delay Serial Number Page Limitations of this Alarm System Limited Warranty System Police With‡K5963V3oŠ

LYNXR Series, LYNXR-EN specifications

The Honeywell LYNXR Series, particularly the LYNXR-EN model, represents a pinnacle of advanced security technology designed for residential and small business applications. This all-in-one wireless security system is lauded for its innovative features, ease of use, and powerful performance, making it a top choice among users seeking enhanced security solutions.

One of the standout features of the LYNXR-EN is its user-friendly touchscreen interface. The large, intuitive display allows for straightforward navigation, enabling users to arm or disarm the system, check status, and receive alerts with just a few taps. This ease of use is complemented by programmable quick access keys, which allow users to personalize their experience according to their security requirements.

Additionally, the LYNXR-EN is designed with flexibility in mind. It supports a wide range of wireless sensors and devices, facilitating comprehensive coverage for homes or small businesses. Users can integrate door and window contacts, motion detectors, glass break sensors, and more, ensuring that every entry point is monitored. The system can accommodate up to 48 wireless zones, allowing for extensive security applications without the clutter of wires.

Technologically, the LYNXR-EN leverages advanced RF technology, enhancing the reliability of communication between the panel and sensors. This feature minimizes the risk of interference and ensures consistent performance even in challenging environments. Along with this robust connectivity, the system offers dual-path communication capabilities, enabling both IP and cellular reporting. This redundancy ensures that alerts are promptly sent to the monitoring center and mobile devices, providing peace of mind to users.

Moreover, the LYNXR-EN can be easily integrated with smart home technology. It is compatible with various smart devices, allowing users to control lighting, thermostats, and other home automation features from a single platform. This integration not only enhances convenience but also optimizes energy efficiency.

The LYNXR-EN also includes a built-in battery backup, ensuring that the system remains operational during power outages. This is a crucial feature for maintaining security when it is needed most. Additionally, users can set up customizable alerts and notifications, allowing them to stay informed of any unusual activity in real-time.

In summary, the Honeywell LYNXR Series, especially the LYNXR-EN model, combines advanced technology with user-friendly design to deliver a versatile and robust security solution. Its wireless capabilities, comprehensive sensor support, smart home integration, and reliable communication make it a prominent choice in the ever-evolving realm of security systems.