Honeywell LYNXR Series, LYNXR-EN setup guide Zone List Menu Mode

Page 34

81 Zone List Menu Mode

While in Program mode, press 81 to enter Zone List Menu Mode. This mode is used to program zone lists for output devices (programmed in 80 menu mode) or Chime-by-Zone in Zone List 3.

NOTES:

Any list may include any or all of the systems zone numbers.

A zone list can be assigned to more than one Powerline Carrier Device.

The prompts for *81 are as follows:

81

A01

b

C d

E

Zone List Programming -------------------

Main Menu prompt

Zone List Number ---------------------------

for entering the zone list number to be programmed

Zone Entry to List ---------------------------

for entering zones to the assigned zone list

Delete Entire List? --------------------------

for deleting the entire zone list and its contents

Delete Specific Zones From List? -------

Selects whether to delete zones or return to next zone list number

Delete Zones-----------------------------------

for deleting specific zones from the current zone list

The following explains these prompts in detail. The left two columns identify the prompts and list the available entries. The right-most column provides a further explanation of the entries.

Notes: (1) Entering a number other than one specified will give unpredictable results.

(2)Do not assign zones with zone types 20, 21 or 22 to a zone list.

 

 

 

 

Zone list programming

Pressing 1 advances to the next prompt below.

 

 

 

 

 

8I

 

0 = exit mode

Pressing 0 exits mode, upon which this prompt blinks, indicating

 

 

 

the mode is inactive.

 

 

 

1 = enter mode

 

 

 

 

 

 

 

 

 

 

Zone list number

Enter the Zone List Number 01, 02, or 03 to program (or 00 if no

 

 

 

 

A

0I

 

01-03 = zone list number to be programmed

zone lists are used).

 

 

 

 

 

00 = exit Zone List mode

 

 

 

 

 

[] = continue

 

 

 

 

 

 

 

 

 

 

 

Zone entry to list

Enter each zone number to add to the zone list by first entering

 

b

 

 

zz

 

01-41, 95, 96, 99 = zone numbers to add to

the zone number, then the [] key (for example, 010203).

 

 

The system will announce the Voice Descriptor for the selected

 

 

zone list

 

 

 

 

[] = accept zone number and enter the next

zone, if it is programmed. After all desired zones are enrolled,

 

 

 

 

 

 

 

 

enter “00” to advance.

 

 

 

 

zone number

 

 

 

 

 

 

 

 

 

00 = accept zone number(s) and continue to

 

 

 

 

 

next prompt

 

 

 

 

 

 

 

 

 

 

 

Delete entire zone list?

To delete the zone list, enter “1”. All zones in the zone list will be

 

 

 

 

C

 

 

0 = don’t delete; continue to next prompt

deleted automatically and programming will return to the ZONE

 

 

 

LIST NUMBER prompt.

 

 

 

1 = delete the current zone list

 

 

 

 

 

To save the zone list or delete specific zones from the list, enter

 

 

 

 

 

“0”.

 

 

 

 

 

 

 

 

 

 

Delete zones from list?

To save the entire zone list, enter “0” and programming will

 

d

 

 

 

 

1 = continue to delete zones prompt

return to the ZONE LIST NUMBER prompt.

 

 

 

To delete a zone or zones in a zone list enter “1”.

 

 

 

0 = don’t delete; continue to next zone list

 

 

 

 

number prompt (A….01)

 

 

 

 

 

[#] = return to zone list number prompt

 

 

 

 

 

(A….01)

 

 

 

 

 

 

 

 

 

 

 

Delete zones

When deleting a zone(s) from the zone list, if the selected zone

 

 

 

 

 

E

 

 

Enter each 2-digit zone number to be deleted

has a Voice Descriptor programmed, upon deletion it will be

 

 

 

announced as a confirmation that it has been deleted. After all

 

 

 

from the current zone list, followed by the []

 

 

 

 

key.

zones to be deleted are entered, enter “00” to return to the ZONE

 

 

 

 

LIST NUMBER prompt so that another list can be programmed,

 

 

 

 

[] = delete zone and enter next zone to be

 

 

 

 

if desired.

 

 

 

 

deleted

 

 

 

 

 

00 = delete zone and return to next zone list

 

 

 

 

 

number prompt (A….01) desired

 

 

 

 

 

 

 

–34–

Image 34
Contents Ademco Lynxr Series Security Systems Recommendations for Smoke and Heat Detectors Recommendations For Proper Intrusion ProtectionTable of Contents Hour backup System FeaturesHardwire zone Two-way voice communication Speaker phone operationMounting the Control Desktop MountingWiring Overview Wiring ConnectionsWiring Connections Full Line Seizure Connections This System 75 to 150 feet AC Power and Backup BatteryAC Power and Rechargeable Backup Battery 150 to 300 feetHours minimum Approximately 1-hour before battery depletion Hours minimum At least 1-hour before battery depletionHouse Identification Installing Wireless ZonesGeneral Information Transmitter SupervisionEnter Installer code 4112 + # + Transmitter Battery LifeUsing the Transmitter Sniffer Mode Go/No Go Test ModeSetting DIP Switches on the 5800RL and 5827 Transmitters Mechanics of Programming Loading Factory DefaultsExiting Program Mode General Programming InformationZone Not Used Type Entry/Exit Burglary #1 Zone Response Type DefinitionsType Type 02 Entry/Exit Burglary #25806/5807/5808 Defaults where applicable are Indicated in Text Data Field DescriptionsDialer Programming Fields 43Report Format for Primary/Secondary Follow Me Reminder Phone NumberPhone System Select Split/Dual ReportingSystem Status and Restore Report Codes Programming 59 76 Restore Report Codes System Status Report CodesRestore Report Codes Download Information 94 Device Programming Menu Mode Enabling the Wireless DialerEnhanced Zone Programming Mode Zone Lists for Menu ModeEnabling the 5842 Wireless Dialer Wireless Dialer SetupEnable back-up reporting Enable the wireless dialerEnable trouble reports Response to phone line tamperEnhanced Zone Programming Mode Report code Zone numberZone type Input typeDelete zone parameters Enroll modeConfirmation Voice descriptor Serial numberDescriptor Start by Event Device Programming Menu ModeProgramming Options Defined Start by Zone Type or System OperationStop Programming Powerline Carrier DevicesUpon Restore of a Zone List Upon a Zone Type or System OperationDevice number Powerline Carrier DeviceProgramming Device actionZone List Menu Mode 00 = exit Sequential mode Enhanced Sequential ModeEnter the 2-digit zone number IA LC = copy the previous serial number entry from the bufferDelete serial number Assign Zone Voice Descriptors Assign zone voice descriptorsAssign Zone Voice Descriptor Voice Vocabulary IndexAssign custom voice descriptors Record Custom Voice DescriptorsCustom descriptor number Voice Prompt Programming Voice Prompt Programming Keypad FunctionsPatio Second Central Station Account NumberFront Basement Back Sliding ToenrollPendant Type To Enter Expert Programming Mode TemplateRemote Programming Information Remote Programming/Control DownloadingEquipment required to download to a system at the premises Remote Programming Advisory Notes Security Codes System OperationPanic Keys Message Center Volume ControlKeypad Functions Other FunctionsRemote Phone Control Feature Remote Phone Control FeatureSpeaker Phone Operation LYNXR-EN Only Operator Commands Alarm Audio Verification Two-Way Voice FeatureActivation Exit Error Alarm Displays Follow Me System Announcement FeaturePowerline Carrier Devices e.g. X-10 devices If programmedTrouble Conditions Fault and Battery DisplaysOther Displays Test Mode Testing the SystemArmed System Test System Communication Communication OverviewContact ID Event Codes Report +1/4+1 Standard +1/4+1 ExpandedTroubleshooting Guide S T E M i n c l u d i n g W i r e l e s sN T R O L O K E D E T E C T O RPLEASE, before you call Technical Support, be sure you Read the InstructionsRegulatory Agency Statements UL Notice This is a Grade a residential systemElectrical SpecificationsLYNXR-Series Security Controls CommunicationLYNXR/LYNXR24 Programming Default Tables LYNXR-EN Programming Default Tables Zone ASSIGNMENT/ALARM Report Codes for Table Event Start StopDevice Number System OperationIndex 20, 61Exit Delay Serial Number Page Limitations of this Alarm System Limited Warranty Police With System‡K5963V3oŠ

LYNXR Series, LYNXR-EN specifications

The Honeywell LYNXR Series, particularly the LYNXR-EN model, represents a pinnacle of advanced security technology designed for residential and small business applications. This all-in-one wireless security system is lauded for its innovative features, ease of use, and powerful performance, making it a top choice among users seeking enhanced security solutions.

One of the standout features of the LYNXR-EN is its user-friendly touchscreen interface. The large, intuitive display allows for straightforward navigation, enabling users to arm or disarm the system, check status, and receive alerts with just a few taps. This ease of use is complemented by programmable quick access keys, which allow users to personalize their experience according to their security requirements.

Additionally, the LYNXR-EN is designed with flexibility in mind. It supports a wide range of wireless sensors and devices, facilitating comprehensive coverage for homes or small businesses. Users can integrate door and window contacts, motion detectors, glass break sensors, and more, ensuring that every entry point is monitored. The system can accommodate up to 48 wireless zones, allowing for extensive security applications without the clutter of wires.

Technologically, the LYNXR-EN leverages advanced RF technology, enhancing the reliability of communication between the panel and sensors. This feature minimizes the risk of interference and ensures consistent performance even in challenging environments. Along with this robust connectivity, the system offers dual-path communication capabilities, enabling both IP and cellular reporting. This redundancy ensures that alerts are promptly sent to the monitoring center and mobile devices, providing peace of mind to users.

Moreover, the LYNXR-EN can be easily integrated with smart home technology. It is compatible with various smart devices, allowing users to control lighting, thermostats, and other home automation features from a single platform. This integration not only enhances convenience but also optimizes energy efficiency.

The LYNXR-EN also includes a built-in battery backup, ensuring that the system remains operational during power outages. This is a crucial feature for maintaining security when it is needed most. Additionally, users can set up customizable alerts and notifications, allowing them to stay informed of any unusual activity in real-time.

In summary, the Honeywell LYNXR Series, especially the LYNXR-EN model, combines advanced technology with user-friendly design to deliver a versatile and robust security solution. Its wireless capabilities, comprehensive sensor support, smart home integration, and reliable communication make it a prominent choice in the ever-evolving realm of security systems.