Data Field Descriptions

35

Entry Delay 01

 

 

The system will wait the time entered before sounding alarm upon entering

00-99 = entry delay time in seconds.

if system is not disarmed. UL installations: must be set for a maximum of

 

45 seconds

 

 

 

 

 

 

 

 

 

36

Entry Delay 02

 

 

The system will wait the time entered before sounding alarm upon

00-99 = entry delay time in seconds.

entering. UL installations: must be set for a maximum of 45 seconds

 

 

 

 

 

37

Audible Exit Warning/Quick Exit

Exit Warning: Sound consists of slow continuous beeps until last 5 seconds,

Exit Warning

 

Quick Exit

when it changes to fast beeps. The warning sound will end at the

 

 

termination of exit delay.

 

0 = no exit warning

 

0 = no quick

Quick Exit: If enabled, user can restart the exit delay time after arming in

 

sound

 

exit

 

 

STAY mode by entering the user code and pressing the STAY key, or by

 

1 = provide exit

 

1 = allow quick

 

 

pressing the STAY key if Quick Arm is enabled. This avoids having the

 

warning sound

 

exit

user disarm then re-arm the system after allowing someone to enter or exit

 

when armed AWAY

 

 

 

 

 

 

38

Confirmation of Arming Ding

Confirmation of arming is provided by a 1/2 second external sounder “ding”

0 = no ding

 

 

that sounds when closing report is sent, or at the end of exit delay.

 

 

 

 

 

1 = confirmation ding after arming system

If Option 2 is selected the external sounder “ding” occurs immediately after

 

2 = confirmation ding after arming from RF button or

 

the system receives the RF transmission.

 

RF keypad only

 

 

 

 

 

 

 

 

 

39

Power Up In Previous State

When the system powers up armed, an alarm will occur 1 minute after

0 = always power up in a disarmed state

arming if a zone is faulted, and any bypassed zones will be unbypassed.

 

Note: If the previous state was armed AWAY or STAY, the system will not

 

1 = assume the system status prior to power-down

 

respond to sensor changes for 1 minute, which allows time for sensors such

 

 

 

 

 

 

 

 

as PIRs to stabilize. UL installations: must be 1 (power up in previous

 

 

 

 

state)

 

 

 

 

 

DIALER PROGRAMMING (40–50)

Fields 40, 41, 42: Enter up to the number of digits shown. Enter 0–9, # + 11 for ‘*’; # + 12 for ‘#’; # + 13 for a pause (2 seconds)

NOTE: Whenever AAV is used, primary (field 41) and secondary (field 42) phone numbers should be preceded with the call waiting disable command. Otherwise, there is the possibility of connection of the third party to LYNX during AAV mode.

40

PABX Access Code

If fewer than 6 digits need to be entered, exit by pressing []. To clear

Enter up to 6 digits if PABX is needed to access an

entries from field, press 40.

 

outside line.

 

 

 

 

41

Primary Phone No.

If fewer than 20 digits entered, exit by pressing []. To clear entries from

Enter up to 20 digits.

field, press 41.

 

 

Note: Backup reporting (8 attempts are made to the secondary phone

 

 

number if no kissoff is received after 8 attempts to the primary

 

 

number) is automatic only if there is a secondary phone number

 

 

(field 42).

 

 

 

42

Secondary Phone No.

If fewer than 24 digits entered, exit by pressing []. To clear entries from

Enter up to 24 digits.

field, press 42. See backup reporting note for field 41. If using the

 

 

paging feature, enter the pager phone number here.

 

 

 

!All four digits of the Subscriber Account number must be entered in Fields 43 and 44. If ten digit format is selected in 48 (option 5), all ten digits of the Subscriber Account number must be entered.

Fields 43 and 44:

Enter [] as the fourth digit if a 3-digit account number (for 3+1 dialer reporting format) is used. Enter 0 as the first digit of a 4-digit account number for Nos. 0000–0999. Enter [] as the fifth digit if a 4-digit account number (for 3+1, CID®) is used. Exit field by pressing [] if only 3 digits are used. To clear entries from field, press 43or 44. See blank Programming Form for examples of account number entries. If using the paging feature, do not enter a leading 0 in the subscriber account number, and do not use digits A-F anywhere in the number. Some paging systems provide voice mail capability, which is activated by a leading 0 in the message. Enter digits 0–9; # +11=B; # +12=C; # +13=D; # +14=E; or # +15=F.

43

Primary Subs Account No.

Enter the primary subscriber account number.

Enter a four or ten digit account number.

To clear entries from field, press 43.

 

 

 

44

Secondary Subs Account No.

Enter the secondary subscriber account number.

Enter a four or ten digit account number.

To clear entries from field, press 44.

 

 

 

–18–

Image 18
Contents Ademco Lynxr Series Security Systems Recommendations for Smoke and Heat Detectors Recommendations For Proper Intrusion ProtectionTable of Contents Hour backup System FeaturesHardwire zone Two-way voice communication Speaker phone operationMounting the Control Desktop MountingWiring Connections Wiring OverviewWiring Connections Full Line Seizure Connections This System 75 to 150 feet AC Power and Backup BatteryAC Power and Rechargeable Backup Battery 150 to 300 feetHours minimum Approximately 1-hour before battery depletion Hours minimum At least 1-hour before battery depletionHouse Identification Installing Wireless ZonesGeneral Information Transmitter SupervisionEnter Installer code 4112 + # + Transmitter Battery LifeUsing the Transmitter Sniffer Mode Go/No Go Test ModeSetting DIP Switches on the 5800RL and 5827 Transmitters Mechanics of Programming Loading Factory DefaultsExiting Program Mode General Programming InformationZone Not Used Type Entry/Exit Burglary #1 Zone Response Type DefinitionsType Type 02 Entry/Exit Burglary #25806/5807/5808 Defaults where applicable are Indicated in Text Data Field DescriptionsDialer Programming Fields 43Report Format for Primary/Secondary Follow Me Reminder Phone NumberPhone System Select Split/Dual ReportingSystem Status and Restore Report Codes Programming 59 76 Restore Report Codes System Status Report CodesRestore Report Codes Download Information 94 Device Programming Menu Mode Enabling the Wireless DialerEnhanced Zone Programming Mode Zone Lists for Menu ModeEnabling the 5842 Wireless Dialer Wireless Dialer SetupEnable back-up reporting Enable the wireless dialerEnable trouble reports Response to phone line tamperEnhanced Zone Programming Mode Report code Zone numberZone type Input typeEnroll mode Delete zone parametersConfirmation Serial number Voice descriptorDescriptor Start by Event Device Programming Menu ModeProgramming Options Defined Start by Zone Type or System OperationStop Programming Powerline Carrier DevicesUpon Restore of a Zone List Upon a Zone Type or System OperationDevice number Powerline Carrier DeviceProgramming Device actionZone List Menu Mode Enhanced Sequential Mode 00 = exit Sequential modeEnter the 2-digit zone number IA LC = copy the previous serial number entry from the bufferDelete serial number Assign Zone Voice Descriptors Assign zone voice descriptorsAssign Zone Voice Descriptor Voice Vocabulary IndexRecord Custom Voice Descriptors Assign custom voice descriptorsCustom descriptor number Voice Prompt Programming Voice Prompt Programming Keypad FunctionsPatio Second Central Station Account NumberFront Basement Back Sliding ToenrollPendant Type To Enter Expert Programming Mode TemplateRemote Programming/Control Downloading Remote Programming InformationEquipment required to download to a system at the premises Remote Programming Advisory Notes System Operation Security CodesPanic Keys Message Center Volume ControlKeypad Functions Other FunctionsRemote Phone Control Feature Remote Phone Control FeatureSpeaker Phone Operation LYNXR-EN Only Alarm Audio Verification Two-Way Voice Feature Operator CommandsActivation Exit Error Alarm Displays Follow Me System Announcement FeaturePowerline Carrier Devices e.g. X-10 devices If programmedFault and Battery Displays Trouble ConditionsOther Displays Testing the System Test ModeArmed System Test System Communication Communication OverviewContact ID Event Codes Report +1/4+1 Standard +1/4+1 ExpandedTroubleshooting Guide S T E M i n c l u d i n g W i r e l e s sN T R O L O K E D E T E C T O RPLEASE, before you call Technical Support, be sure you Read the InstructionsRegulatory Agency Statements UL Notice This is a Grade a residential systemElectrical SpecificationsLYNXR-Series Security Controls CommunicationLYNXR/LYNXR24 Programming Default Tables LYNXR-EN Programming Default Tables Zone ASSIGNMENT/ALARM Report Codes for Table Event Start StopDevice Number System OperationIndex 20, 61Exit Delay Serial Number Page Limitations of this Alarm System Limited Warranty Police With System‡K5963V3oŠ

LYNXR Series, LYNXR-EN specifications

The Honeywell LYNXR Series, particularly the LYNXR-EN model, represents a pinnacle of advanced security technology designed for residential and small business applications. This all-in-one wireless security system is lauded for its innovative features, ease of use, and powerful performance, making it a top choice among users seeking enhanced security solutions.

One of the standout features of the LYNXR-EN is its user-friendly touchscreen interface. The large, intuitive display allows for straightforward navigation, enabling users to arm or disarm the system, check status, and receive alerts with just a few taps. This ease of use is complemented by programmable quick access keys, which allow users to personalize their experience according to their security requirements.

Additionally, the LYNXR-EN is designed with flexibility in mind. It supports a wide range of wireless sensors and devices, facilitating comprehensive coverage for homes or small businesses. Users can integrate door and window contacts, motion detectors, glass break sensors, and more, ensuring that every entry point is monitored. The system can accommodate up to 48 wireless zones, allowing for extensive security applications without the clutter of wires.

Technologically, the LYNXR-EN leverages advanced RF technology, enhancing the reliability of communication between the panel and sensors. This feature minimizes the risk of interference and ensures consistent performance even in challenging environments. Along with this robust connectivity, the system offers dual-path communication capabilities, enabling both IP and cellular reporting. This redundancy ensures that alerts are promptly sent to the monitoring center and mobile devices, providing peace of mind to users.

Moreover, the LYNXR-EN can be easily integrated with smart home technology. It is compatible with various smart devices, allowing users to control lighting, thermostats, and other home automation features from a single platform. This integration not only enhances convenience but also optimizes energy efficiency.

The LYNXR-EN also includes a built-in battery backup, ensuring that the system remains operational during power outages. This is a crucial feature for maintaining security when it is needed most. Additionally, users can set up customizable alerts and notifications, allowing them to stay informed of any unusual activity in real-time.

In summary, the Honeywell LYNXR Series, especially the LYNXR-EN model, combines advanced technology with user-friendly design to deliver a versatile and robust security solution. Its wireless capabilities, comprehensive sensor support, smart home integration, and reliable communication make it a prominent choice in the ever-evolving realm of security systems.