Honeywell LYNXR Series, LYNXR-EN Assign Zone Voice Descriptors, Assign zone voice descriptors

Page 38

84 Assign Zone Voice Descriptors

Use this mode to assign voice descriptors for each zone. These are the descriptors that are announced when the system announces any event involving a zone number. Each descriptor can consist of up to 3 words. Press 84 while in Programming mode.

The prompts for 84 are as follows:

84

A01

b

C d

Voice Descriptors ----------------------

Main Menu prompt

Zone Number ---------------------------

for entering the zone number to be programmed

Descriptor 1 -----------------------------

for assigning the first word of this zone’s descriptor

Descriptor 2 -----------------------------

for assigning the second word of this zone’s descriptor

Descriptor 3 -----------------------------

for assigning the third word of this zone’s descriptor

The following explains these prompts in detail. The left two columns identify the prompts and list the available entries. The right-most column provides a further explanation of the entries.

Note: Entering a number other than the one specified will give unpredictable results.

 

 

 

 

Assign zone voice descriptors

Pressing 1 advances to the next prompt below.

 

 

 

 

 

84

 

0 = exit mode

Pressing 0 exits mode, upon which this prompt blinks, indicating the

 

 

 

mode is inactive.

 

 

 

1 = enter mode

 

 

 

 

 

 

 

 

 

 

Zone number

Enter the 2-digit zone number for which this descriptor is being

 

 

 

 

A

zz

 

[] = continue to next prompt (any existing

assigned, then press []. The Voice Descriptor for the selected zone will

 

 

be announced, if it is programmed.

 

 

descriptors will be announced, then

 

 

 

 

descriptor 1 will be repeated)

 

 

 

 

 

00 = exit voice descriptor mode

 

 

 

 

 

 

 

 

 

 

 

Descriptor 1

Enter the first word of the descriptor for the selected zone.

 

b

 

 

vv

 

Enter [#] + 2-digit vocabulary index number of

Use the [6] or [8] key to advance as described.

 

 

To change the entered index number before pressing [6] or [8], simply

 

 

first descriptor word for this zone.

 

 

 

 

6 = accept word and advance to descriptor 2

press [#] + desired 2-digit vocabulary index number.

 

 

 

 

If descriptor 1 is not desired, enter [#] + 99 (blank), then press [8] to

 

 

 

 

(descriptor 2 will be announced)

 

 

 

 

return to zone number prompt.

 

 

 

 

8 = accept word and advance to prompt (A) for

 

 

 

 

 

next zone. Press any other key to repeat the

 

 

 

 

 

selected word.

 

 

 

 

 

 

 

 

 

 

 

Descriptor 2

Enter the second word of the descriptor for the selected zone.

 

 

 

 

C

vv

 

Enter [#] + 2-digit vocabulary index number of

Use the [6] or [8] key to advance as described.

 

 

To change the entered index number before pressing [6] or [8], simply

 

 

second descriptor word for this zone.

 

 

 

 

6 = accept word and advance to descriptor 3

press [#] + desired 2-digit vocabulary index number.

 

 

 

 

If descriptor 2 is not desired, enter [#] + 99 (blank), then press [8] to

 

 

 

 

(descriptor 3 will be announced)

 

 

 

 

return to zone number prompt.

 

 

 

 

8 = accept word and advance to prompt (A) for

 

 

 

 

 

next zone. Press any other key to repeat the

 

 

 

 

 

selected word.

 

 

 

 

 

 

 

 

 

 

 

Descriptor 3

Enter the last word of the descriptor for the selected zone.

 

d

 

 

vv

 

Enter [#] + 2-digit vocabulary index number of

Use the [6] or [8] key to advance as described.

 

 

To change the entered index number before pressing [6] or [8], simply

 

 

third descriptor word for this zone.

 

 

 

 

6 or 8 = accept word and advance to prompt

press [#] + desired 2-digit vocabulary index number.

 

 

 

 

If descriptor 3 is not desired, enter [#] + 99 (blank), then press [8] to

 

 

 

 

(A) for next zone. Zone descriptor will

 

 

 

 

return to zone number prompt.

 

 

 

 

be announced. Press any other key to

 

 

 

 

 

repeat the selected word.

 

 

 

 

 

 

 

–38–

Image 38
Contents Ademco Lynxr Series Security Systems Recommendations for Smoke and Heat Detectors Recommendations For Proper Intrusion ProtectionTable of Contents Hour backup System FeaturesHardwire zone Two-way voice communication Speaker phone operationMounting the Control Desktop MountingWiring Connections Wiring ConnectionsWiring Overview Full Line Seizure Connections This System 75 to 150 feet AC Power and Backup BatteryAC Power and Rechargeable Backup Battery 150 to 300 feetHours minimum Approximately 1-hour before battery depletion Hours minimum At least 1-hour before battery depletionHouse Identification Installing Wireless ZonesGeneral Information Transmitter SupervisionEnter Installer code 4112 + # + Transmitter Battery LifeUsing the Transmitter Sniffer Mode Go/No Go Test ModeSetting DIP Switches on the 5800RL and 5827 Transmitters Mechanics of Programming Loading Factory DefaultsExiting Program Mode General Programming InformationZone Not Used Type Entry/Exit Burglary #1 Zone Response Type DefinitionsType Type 02 Entry/Exit Burglary #25806/5807/5808 Defaults where applicable are Indicated in Text Data Field DescriptionsDialer Programming Fields 43Report Format for Primary/Secondary Follow Me Reminder Phone NumberPhone System Select Split/Dual ReportingSystem Status and Restore Report Codes Programming 59 76 Restore Report Codes System Status Report CodesRestore Report Codes Download Information 94 Device Programming Menu Mode Enabling the Wireless DialerEnhanced Zone Programming Mode Zone Lists for Menu ModeEnabling the 5842 Wireless Dialer Wireless Dialer SetupEnable back-up reporting Enable the wireless dialerEnable trouble reports Response to phone line tamperEnhanced Zone Programming Mode Report code Zone numberZone type Input typeConfirmation Enroll modeDelete zone parameters Descriptor Serial numberVoice descriptor Start by Event Device Programming Menu ModeProgramming Options Defined Start by Zone Type or System OperationStop Programming Powerline Carrier DevicesUpon Restore of a Zone List Upon a Zone Type or System OperationDevice number Powerline Carrier DeviceProgramming Device actionZone List Menu Mode Enter the 2-digit zone number Enhanced Sequential Mode00 = exit Sequential mode IA LC = copy the previous serial number entry from the bufferDelete serial number Assign Zone Voice Descriptors Assign zone voice descriptorsAssign Zone Voice Descriptor Voice Vocabulary IndexCustom descriptor number Record Custom Voice DescriptorsAssign custom voice descriptors Voice Prompt Programming Voice Prompt Programming Keypad FunctionsPatio Second Central Station Account NumberFront Basement Back Sliding ToenrollPendant Type To Enter Expert Programming Mode TemplateEquipment required to download to a system at the premises Remote Programming/Control DownloadingRemote Programming Information Remote Programming Advisory Notes Panic Keys System OperationSecurity Codes Message Center Volume ControlKeypad Functions Other FunctionsSpeaker Phone Operation LYNXR-EN Only Remote Phone Control FeatureRemote Phone Control Feature Activation Alarm Audio Verification Two-Way Voice FeatureOperator Commands Exit Error Alarm Displays Follow Me System Announcement FeaturePowerline Carrier Devices e.g. X-10 devices If programmedOther Displays Fault and Battery DisplaysTrouble Conditions Armed System Test Testing the SystemTest Mode System Communication Communication OverviewContact ID Event Codes Report +1/4+1 Standard +1/4+1 ExpandedTroubleshooting Guide S T E M i n c l u d i n g W i r e l e s sN T R O L O K E D E T E C T O RPLEASE, before you call Technical Support, be sure you Read the InstructionsRegulatory Agency Statements UL Notice This is a Grade a residential systemElectrical SpecificationsLYNXR-Series Security Controls CommunicationLYNXR/LYNXR24 Programming Default Tables LYNXR-EN Programming Default Tables Zone ASSIGNMENT/ALARM Report Codes for Table Event Start StopDevice Number System OperationIndex 20, 61Exit Delay Serial Number Page Limitations of this Alarm System Limited Warranty Police With System‡K5963V3oŠ

LYNXR Series, LYNXR-EN specifications

The Honeywell LYNXR Series, particularly the LYNXR-EN model, represents a pinnacle of advanced security technology designed for residential and small business applications. This all-in-one wireless security system is lauded for its innovative features, ease of use, and powerful performance, making it a top choice among users seeking enhanced security solutions.

One of the standout features of the LYNXR-EN is its user-friendly touchscreen interface. The large, intuitive display allows for straightforward navigation, enabling users to arm or disarm the system, check status, and receive alerts with just a few taps. This ease of use is complemented by programmable quick access keys, which allow users to personalize their experience according to their security requirements.

Additionally, the LYNXR-EN is designed with flexibility in mind. It supports a wide range of wireless sensors and devices, facilitating comprehensive coverage for homes or small businesses. Users can integrate door and window contacts, motion detectors, glass break sensors, and more, ensuring that every entry point is monitored. The system can accommodate up to 48 wireless zones, allowing for extensive security applications without the clutter of wires.

Technologically, the LYNXR-EN leverages advanced RF technology, enhancing the reliability of communication between the panel and sensors. This feature minimizes the risk of interference and ensures consistent performance even in challenging environments. Along with this robust connectivity, the system offers dual-path communication capabilities, enabling both IP and cellular reporting. This redundancy ensures that alerts are promptly sent to the monitoring center and mobile devices, providing peace of mind to users.

Moreover, the LYNXR-EN can be easily integrated with smart home technology. It is compatible with various smart devices, allowing users to control lighting, thermostats, and other home automation features from a single platform. This integration not only enhances convenience but also optimizes energy efficiency.

The LYNXR-EN also includes a built-in battery backup, ensuring that the system remains operational during power outages. This is a crucial feature for maintaining security when it is needed most. Additionally, users can set up customizable alerts and notifications, allowing them to stay informed of any unusual activity in real-time.

In summary, the Honeywell LYNXR Series, especially the LYNXR-EN model, combines advanced technology with user-friendly design to deliver a versatile and robust security solution. Its wireless capabilities, comprehensive sensor support, smart home integration, and reliable communication make it a prominent choice in the ever-evolving realm of security systems.