Honeywell LYNXR-EN, LYNXR Series setup guide Assign Zone Voice Descriptor, Voice Vocabulary Index

Page 39

84 Assign Zone Voice Descriptor

VOICE VOCABULARY INDEX

00 ½ second pause

A

82ALARM

32ATTIC

B

01BABY

33BACK

34BASEMENT

35BATHROOM

36BEDROOM

C

83 CHECK

D

37DELAY DOOR

38DEN

02DETECTOR

03DINING

39DINING ROOM

04DOOR

40DOWNSTAIRS

05DRIVEWAY

E

06EAST

41EIGHT

42EMERGENCY

F

43FAMILY ROOM

87FIRE

44FIRE DETECTION

07FIRST FLOOR

45FIVE

08FLOOR

46FOUR

47FRONT

G

48GARAGE

49GUEST ROOM

09GUN

H 50 HALL

I

10 INSIDE

K

51 KITCHEN

L

11LAUNDRY

52LAUNDRY ROOM

12LIBRARY

13LIVING

53 LIVING ROOM

M

14MAIN

15MASTER

54MASTER BEDROOM

55MEDICAL

84MESSAGE

56MOTION DETECTOR

N

57NINE

16NORTH

58NURSERY

O

59OFFICE

60ONE

17 OUTSIDE

P

61PATIO

62POLICE

18POOL

R

63REAR

19ROOM

S

64SECOND FLOOR

65SEVEN

20SHED

21SHOP

66SIDE

67SILENT POLICE

68SIX

69SLIDING

22SMOKE

23SOUTH

24STORAGE

85 SYSTEM

T

25THIRD FLOOR

75THREE

76TRANSMITTER

77TWO

U

78UPSTAIRS

26UTILITY

79UTILITY ROOM

W

27 WEST

80 WINDOW

Y

28 YARD

Z

81ZERO

86ZONES

291ST

302ND

313RD

70Custom Word #1

71Custom Word #2

72Custom Word #3

73Custom Word #4

74Custom Word #5

99Blank (for erasing a previously programmed word)

SYSTEM WORDS AC LOSS ARMED

AWAY BYPASSED CHIME DISARMED DISARM SYSTEM NOW

EXIT NOW FAULT INSTANT LOW BATTERY NOT

READY TO ARM STAY

Note: If button type device is used to Arm Away, Arm Stay, and disarm the system it is recommended to assign “Check” and “Zones” voice descriptors to each of the three zones. This will allow the system to announce “Check Zones” “Low Battery” if the button device has a low battery.

–39–

Image 39
Contents Ademco Lynxr Series Security Systems Recommendations For Proper Intrusion Protection Recommendations for Smoke and Heat DetectorsTable of Contents Two-way voice communication Speaker phone operation System FeaturesHardwire zone Hour backupDesktop Mounting Mounting the ControlWiring Connections Wiring OverviewWiring Connections Full Line Seizure Connections This System 150 to 300 feet AC Power and Backup BatteryAC Power and Rechargeable Backup Battery 75 to 150 feetHours minimum At least 1-hour before battery depletion Hours minimum Approximately 1-hour before battery depletionTransmitter Supervision Installing Wireless ZonesGeneral Information House IdentificationGo/No Go Test Mode Transmitter Battery LifeUsing the Transmitter Sniffer Mode Enter Installer code 4112 + # +Setting DIP Switches on the 5800RL and 5827 Transmitters General Programming Information Loading Factory DefaultsExiting Program Mode Mechanics of ProgrammingType 02 Entry/Exit Burglary #2 Zone Response Type DefinitionsType Zone Not Used Type Entry/Exit Burglary #15806/5807/5808 Data Field Descriptions Defaults where applicable are Indicated in TextFields 43 Dialer ProgrammingSplit/Dual Reporting Follow Me Reminder Phone NumberPhone System Select Report Format for Primary/SecondarySystem Status and Restore Report Codes Programming 59 76 System Status Report Codes Restore Report CodesRestore Report Codes Download Information 94 Zone Lists for Menu Mode Enabling the Wireless DialerEnhanced Zone Programming Mode Device Programming Menu ModeWireless Dialer Setup Enabling the 5842 Wireless DialerResponse to phone line tamper Enable the wireless dialerEnable trouble reports Enable back-up reportingEnhanced Zone Programming Mode Input type Zone numberZone type Report codeEnroll mode Delete zone parametersConfirmation Serial number Voice descriptorDescriptor Start by Zone Type or System Operation Device Programming Menu ModeProgramming Options Defined Start by EventUpon a Zone Type or System Operation Programming Powerline Carrier DevicesUpon Restore of a Zone List StopDevice action Powerline Carrier DeviceProgramming Device numberZone List Menu Mode Enhanced Sequential Mode 00 = exit Sequential modeEnter the 2-digit zone number = copy the previous serial number entry from the buffer IA LCDelete serial number Assign zone voice descriptors Assign Zone Voice DescriptorsVoice Vocabulary Index Assign Zone Voice DescriptorRecord Custom Voice Descriptors Assign custom voice descriptorsCustom descriptor number Voice Prompt Programming Keypad Functions Voice Prompt ProgrammingToenroll Second Central Station Account NumberFront Basement Back Sliding PatioPendant Type Template To Enter Expert Programming ModeRemote Programming/Control Downloading Remote Programming InformationEquipment required to download to a system at the premises Remote Programming Advisory Notes System Operation Security CodesPanic Keys Other Functions Volume ControlKeypad Functions Message CenterRemote Phone Control Feature Remote Phone Control FeatureSpeaker Phone Operation LYNXR-EN Only Alarm Audio Verification Two-Way Voice Feature Operator CommandsActivation If programmed Follow Me System Announcement FeaturePowerline Carrier Devices e.g. X-10 devices Exit Error Alarm DisplaysFault and Battery Displays Trouble ConditionsOther Displays Testing the System Test ModeArmed System Test Communication Overview System CommunicationReport +1/4+1 Standard +1/4+1 Expanded Contact ID Event CodesS T E M i n c l u d i n g W i r e l e s s Troubleshooting GuideO K E D E T E C T O R N T R O LRead the Instructions PLEASE, before you call Technical Support, be sure youUL Notice This is a Grade a residential system Regulatory Agency StatementsCommunication SpecificationsLYNXR-Series Security Controls ElectricalLYNXR/LYNXR24 Programming Default Tables LYNXR-EN Programming Default Tables Zone ASSIGNMENT/ALARM Report Codes for Table System Operation Start StopDevice Number Event20, 61 IndexExit Delay Serial Number Page Limitations of this Alarm System Limited Warranty System Police With‡K5963V3oŠ

LYNXR Series, LYNXR-EN specifications

The Honeywell LYNXR Series, particularly the LYNXR-EN model, represents a pinnacle of advanced security technology designed for residential and small business applications. This all-in-one wireless security system is lauded for its innovative features, ease of use, and powerful performance, making it a top choice among users seeking enhanced security solutions.

One of the standout features of the LYNXR-EN is its user-friendly touchscreen interface. The large, intuitive display allows for straightforward navigation, enabling users to arm or disarm the system, check status, and receive alerts with just a few taps. This ease of use is complemented by programmable quick access keys, which allow users to personalize their experience according to their security requirements.

Additionally, the LYNXR-EN is designed with flexibility in mind. It supports a wide range of wireless sensors and devices, facilitating comprehensive coverage for homes or small businesses. Users can integrate door and window contacts, motion detectors, glass break sensors, and more, ensuring that every entry point is monitored. The system can accommodate up to 48 wireless zones, allowing for extensive security applications without the clutter of wires.

Technologically, the LYNXR-EN leverages advanced RF technology, enhancing the reliability of communication between the panel and sensors. This feature minimizes the risk of interference and ensures consistent performance even in challenging environments. Along with this robust connectivity, the system offers dual-path communication capabilities, enabling both IP and cellular reporting. This redundancy ensures that alerts are promptly sent to the monitoring center and mobile devices, providing peace of mind to users.

Moreover, the LYNXR-EN can be easily integrated with smart home technology. It is compatible with various smart devices, allowing users to control lighting, thermostats, and other home automation features from a single platform. This integration not only enhances convenience but also optimizes energy efficiency.

The LYNXR-EN also includes a built-in battery backup, ensuring that the system remains operational during power outages. This is a crucial feature for maintaining security when it is needed most. Additionally, users can set up customizable alerts and notifications, allowing them to stay informed of any unusual activity in real-time.

In summary, the Honeywell LYNXR Series, especially the LYNXR-EN model, combines advanced technology with user-friendly design to deliver a versatile and robust security solution. Its wireless capabilities, comprehensive sensor support, smart home integration, and reliable communication make it a prominent choice in the ever-evolving realm of security systems.