Honeywell LYNXR-EN setup guide Powerline Carrier Device, Programming, Device number, Device action

Page 33

80 Device Programming Menu Mode

The following explains these prompts in detail. The left two columns identify the prompts and list the available entries. The right-most column provides a further explanation of the entries.

Note: Entering a number other than one specified will give unpredictable results.

 

 

 

 

Powerline Carrier Device

Entering “1” advances to the next prompt below.

 

 

 

 

 

 

 

80

 

programming

 

Entering “0” exits mode, upon which this prompt blinks, indicating the

 

 

 

 

mode is inactive.

 

 

 

 

 

 

0 = exit mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 = enter mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Device number

 

Enter device numbers as 2-digit entries.

 

 

A

0I

 

 

 

 

01-08 = device number to be programmed

 

 

 

 

 

 

[] = continue

 

 

 

 

 

 

 

 

 

00 = exit Device Programming mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Device action

 

Enter the 1-digit action (0-3) for the device being programmed (current

 

b

 

 

 

aa

 

0 = No response

 

action is displayed).

 

 

 

 

 

 

NOTES:

 

 

 

 

 

1 = Close for 2 seconds

 

 

 

 

 

 

 

2 = Close and Stay Closed

1. If “3” is entered (pulse), only up to 3 different devices can be pulsed

 

 

 

 

if one of the devices is a siren/horn (X-10 Powerhouse Security

 

 

 

 

3 = Continuous Pulse on & off (1 sec ON, 1 sec

 

 

 

 

model SH10A). In addition, the siren/horn cannot be manually

 

 

 

 

OFF)

 

activated using the lights on/lights off keypad commands.

 

 

 

 

[] = continue

 

2. If using an X-10 Powerhouse Security SH10A siren:

 

 

 

 

[#] = return to previous prompt

• you must use device action “3.”

 

 

 

 

 

 

 

• you must change the device action default to “3” if using default

 

 

 

 

 

 

table 2 or 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start event type

 

Enter the 1-digit event type (0-3) to activate the device being

 

 

 

 

 

C

et

 

0 = Not used

3 = Trouble

programmed. A zone list must be used in conjunction with an event. If

 

 

a zone type/system operation is to be used instead of an event, enter

 

 

1 = Alarm

[] = continue

 

 

 

 

2 = Fault

[#] = return to previous

“0”.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

prompt

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start zone list

 

If a zone list will be used to start the device action, enter the zone list

 

d

 

 

 

zl

 

1-3 = zone list number (to be programmed in

number at this prompt.

 

 

 

 

 

 

 

 

 

 

field 81)

 

 

 

 

 

 

 

 

 

0 = zone list not used for this device

 

 

 

 

 

 

 

 

[] = continue

 

 

 

 

 

 

 

 

 

[#] = return to previous prompt

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start zone type

 

If a zone type or system operation will be used to start the device

 

E

 

 

 

zt

 

01-58 = zone type to start this device action

action, enter the appropriate 2-digit code for the device being

 

 

(select only those that are applicable)

programmed (see table that follows).

 

 

 

 

 

00 = zone type not used for this device

 

Choices for zone types

 

 

 

 

 

[] = continue

 

00 = Not Used

04 = Interior Follower

08 = 24 Hr Aux

 

 

 

 

[#] = return to previous prompt

01 = Entry/Exit #1

05 = Trouble Day/Alarm Night 09 = Fire

 

 

 

 

 

 

02 = Entry/Exit #2

06 = 24 Hr Silent

10 = Interior w/Delay

 

 

 

 

 

 

03 = Perimeter

07 = 24 Hr Audible

24 = Silent Burglary

 

 

 

 

 

 

Choices for system operation

 

 

 

 

 

 

20 = Arming–Stay

33 = Any Alarm (except zt 08)

42 = Sys. Batt. Low

 

 

 

 

 

 

21 = Arming–Away

36 = At Bell Timeout**

43 = Comm. Failure

 

 

 

 

 

 

22 = Disarm. (Code + OFF)

38 = Chime

52 = Kissoff

 

 

 

 

 

 

31 = End of Exit Time

39 = Any Fire Alarm

58 = Duress

 

 

 

 

 

 

32 = Start of Entry Time

40 = Bypassing

 

 

 

 

 

 

 

** Or at Disarming (which ever occurs earlier)

 

 

 

 

 

 

 

Note: If an X-10 device has been programmed to ZT05 or ZT07 and *55

 

 

 

 

 

 

has been enabled, the device response will be dependent upon the

 

 

 

 

 

 

selection made in *55 Field "Ln".

 

 

 

 

 

 

 

 

 

 

 

 

Stop zone list

 

If a zone list will be used to STOP, or restore, the device action, enter

 

F

zl

 

1-3 = zone list to stop this device action

the zone list number 1, 2, or 3 (to be programmed in 81 mode). If not

 

 

used, enter “0”.

 

 

 

 

 

0 = zone list not used

 

 

 

 

 

 

 

 

[] = continue

 

 

 

 

 

 

 

 

 

[#] = return to previous prompt

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stop zone type

 

If a zone type or system operation will be used to STOP the device

 

 

 

 

 

IA

zt

 

01-58 = zone type to start this device action

action, enter the appropriate 2-digit code (see the "ZT" choices listed

 

 

above). If not, enter 00.

 

 

 

 

(select only those that are applicable)

 

 

 

 

 

 

00 = zone type not used for this device

The display then returns to the DEVICE NUMBER prompt (A) so that

 

 

 

 

you can enter the next device number to be programmed, or enter [0][0]

 

 

 

 

[] = continue

 

 

 

 

 

 

to end device programming.

 

 

 

 

 

[#] = return to previous prompt

 

 

 

 

–33–

Image 33
Contents Ademco Lynxr Series Security Systems Recommendations For Proper Intrusion Protection Recommendations for Smoke and Heat DetectorsTable of Contents Hardwire zone System FeaturesHour backup Two-way voice communication Speaker phone operationDesktop Mounting Mounting the ControlWiring Connections Wiring OverviewWiring Connections Full Line Seizure Connections This System AC Power and Rechargeable Backup Battery AC Power and Backup Battery75 to 150 feet 150 to 300 feetHours minimum At least 1-hour before battery depletion Hours minimum Approximately 1-hour before battery depletionGeneral Information Installing Wireless ZonesHouse Identification Transmitter SupervisionUsing the Transmitter Sniffer Mode Transmitter Battery LifeEnter Installer code 4112 + # + Go/No Go Test ModeSetting DIP Switches on the 5800RL and 5827 Transmitters Exiting Program Mode Loading Factory DefaultsMechanics of Programming General Programming InformationType Zone Response Type DefinitionsZone Not Used Type Entry/Exit Burglary #1 Type 02 Entry/Exit Burglary #25806/5807/5808 Data Field Descriptions Defaults where applicable are Indicated in TextFields 43 Dialer ProgrammingPhone System Select Follow Me Reminder Phone NumberReport Format for Primary/Secondary Split/Dual ReportingSystem Status and Restore Report Codes Programming 59 76 System Status Report Codes Restore Report CodesRestore Report Codes Download Information 94 Enhanced Zone Programming Mode Enabling the Wireless DialerDevice Programming Menu Mode Zone Lists for Menu ModeWireless Dialer Setup Enabling the 5842 Wireless DialerEnable trouble reports Enable the wireless dialerEnable back-up reporting Response to phone line tamperEnhanced Zone Programming Mode Zone type Zone numberReport code Input typeEnroll mode Delete zone parametersConfirmation Serial number Voice descriptorDescriptor Programming Options Defined Device Programming Menu ModeStart by Event Start by Zone Type or System OperationUpon Restore of a Zone List Programming Powerline Carrier DevicesStop Upon a Zone Type or System OperationProgramming Powerline Carrier DeviceDevice number Device actionZone List Menu Mode Enhanced Sequential Mode 00 = exit Sequential modeEnter the 2-digit zone number = copy the previous serial number entry from the buffer IA LCDelete serial number Assign zone voice descriptors Assign Zone Voice DescriptorsVoice Vocabulary Index Assign Zone Voice DescriptorRecord Custom Voice Descriptors Assign custom voice descriptorsCustom descriptor number Voice Prompt Programming Keypad Functions Voice Prompt ProgrammingFront Basement Back Sliding Second Central Station Account NumberPatio ToenrollPendant Type Template To Enter Expert Programming ModeRemote Programming/Control Downloading Remote Programming InformationEquipment required to download to a system at the premises Remote Programming Advisory Notes System Operation Security CodesPanic Keys Keypad Functions Volume ControlMessage Center Other FunctionsRemote Phone Control Feature Remote Phone Control FeatureSpeaker Phone Operation LYNXR-EN Only Alarm Audio Verification Two-Way Voice Feature Operator CommandsActivation Powerline Carrier Devices e.g. X-10 devices Follow Me System Announcement FeatureExit Error Alarm Displays If programmedFault and Battery Displays Trouble ConditionsOther Displays Testing the System Test ModeArmed System Test Communication Overview System CommunicationReport +1/4+1 Standard +1/4+1 Expanded Contact ID Event CodesS T E M i n c l u d i n g W i r e l e s s Troubleshooting GuideO K E D E T E C T O R N T R O LRead the Instructions PLEASE, before you call Technical Support, be sure youUL Notice This is a Grade a residential system Regulatory Agency StatementsLYNXR-Series Security Controls SpecificationsElectrical CommunicationLYNXR/LYNXR24 Programming Default Tables LYNXR-EN Programming Default Tables Zone ASSIGNMENT/ALARM Report Codes for Table Device Number Start StopEvent System Operation20, 61 IndexExit Delay Serial Number Page Limitations of this Alarm System Limited Warranty System Police With‡K5963V3oŠ

LYNXR Series, LYNXR-EN specifications

The Honeywell LYNXR Series, particularly the LYNXR-EN model, represents a pinnacle of advanced security technology designed for residential and small business applications. This all-in-one wireless security system is lauded for its innovative features, ease of use, and powerful performance, making it a top choice among users seeking enhanced security solutions.

One of the standout features of the LYNXR-EN is its user-friendly touchscreen interface. The large, intuitive display allows for straightforward navigation, enabling users to arm or disarm the system, check status, and receive alerts with just a few taps. This ease of use is complemented by programmable quick access keys, which allow users to personalize their experience according to their security requirements.

Additionally, the LYNXR-EN is designed with flexibility in mind. It supports a wide range of wireless sensors and devices, facilitating comprehensive coverage for homes or small businesses. Users can integrate door and window contacts, motion detectors, glass break sensors, and more, ensuring that every entry point is monitored. The system can accommodate up to 48 wireless zones, allowing for extensive security applications without the clutter of wires.

Technologically, the LYNXR-EN leverages advanced RF technology, enhancing the reliability of communication between the panel and sensors. This feature minimizes the risk of interference and ensures consistent performance even in challenging environments. Along with this robust connectivity, the system offers dual-path communication capabilities, enabling both IP and cellular reporting. This redundancy ensures that alerts are promptly sent to the monitoring center and mobile devices, providing peace of mind to users.

Moreover, the LYNXR-EN can be easily integrated with smart home technology. It is compatible with various smart devices, allowing users to control lighting, thermostats, and other home automation features from a single platform. This integration not only enhances convenience but also optimizes energy efficiency.

The LYNXR-EN also includes a built-in battery backup, ensuring that the system remains operational during power outages. This is a crucial feature for maintaining security when it is needed most. Additionally, users can set up customizable alerts and notifications, allowing them to stay informed of any unusual activity in real-time.

In summary, the Honeywell LYNXR Series, especially the LYNXR-EN model, combines advanced technology with user-friendly design to deliver a versatile and robust security solution. Its wireless capabilities, comprehensive sensor support, smart home integration, and reliable communication make it a prominent choice in the ever-evolving realm of security systems.