Honeywell LYNXR Series, LYNXR-EN Mechanics of Programming, General Programming Information

Page 14

Mechanics of Programming

General Programming Information

Programming options are stored in non-removable, electrically erasable, nonvolatile EEROM memory. The system can be programmed at any time, even at the installer's premises prior to the actual installation. Simply apply power temporarily to the Control and then program the unit as desired. There are two programming modes:

Data field programming (used for setting various system options)

Interactive menu mode programming (used for programming zone information, programming Powerline Carrier

Devices, and for entering transmitter serial numbers)

The system can also be programmed remotely, using an IBM Personal Computer, a modem, and Compass Downloader for Windows. See the Remote Programming/Control (Downloading) section.

Note:

!

You may find it convenient to adjust the volume setting before entering the Program Mode. This will allow you to clearly hear the feedback announcements or system beeps in the Programming Mode, of the system’s built-in speaker. To adjust the volume, press FUNCTION + VOLUME+ [3] or [6]. Upon exiting the Program Mode, the system will reset the volume to the default value (mid level).

Certain features differ between the LYNXR/LYNXR24 and the LYNXR-EN models. Verify the specific model being installed prior to the system programming.

Entering Program Mode - Use one of the following methods to enter Programming Mode:

1.Press both the [] and [#] keys at the same time, within 50 seconds after power is applied to the Control or from exiting Programming mode, OR

2.After power-up, enter the Installer Code (4112) + 800 (This method disabled if Program mode is exited using 98.) to enter Expert Programming mode or Installer Code (4112) + 888 to enter Voice Prompt Programming mode.

Notes: 1. If a different Installer Code has been programmed, use that code to enter the Programming mode. Once you have entered the Program mode, data field 20 (the first data field in the system) will be displayed and both keypad LEDs will flash.

2.Entering Programming mode may take up to 18 seconds if the 5842 Wireless Dialer has been enabled. The system will display “ - - “ until the Lynx enters Programming mode.

Programming a Data Field

1.Press [] + Field No. (for example, 21), followed by the required entry.

2.When you have completely programmed a data field, the keypad will “beep” three times and then automatically display the next data field in sequence. To go to a different field, press [] plus the desired field number.

3.If the number of digits that will be entered in a data field is less than the maximum number of digits available (e.g. phone number field), enter the desired data, then press [] to advance to the next data field.

4.If a nonexistent field has been entered, the keypad will display “EE”. Simply re-enter [] plus a valid field number. To view a data field without making changes: Enter [#] + Field No. Data will be displayed for that field.

To delete an entry in a field: Enter [] + Field No. + []. (Applies only to fields 40–44, 88 and 94). Interactive Mode Programming (56, 80, 81, 83, 84, 85)

Press [] + interactive mode No. (for example, 56). The keypad will display the first of a series of prompts. A detailed procedure (with displays of prompts) is provided in later sections of this manual.

 

Interactive Mode

Used to Program

56 Enhanced Zone Programming Mode

Zone characteristics, report codes, and serial numbers

80 Device Programming Menu Mode

Powerline Carrier Devices

81

Zone List Menu Mode

Zone Lists for powerline carrier activation

83

Enhanced Sequential Mode

5800 Series transmitter serial numbers

84

Assign Zone Voice Descriptors

Voice descriptors for each zone

85

Record Custom Voice Descriptors

Up to 5 custom voice descriptors for zones

Loading Factory Defaults

To load the factory defaults, enter the Programming mode, press 97, then press number 1, 2, 3, or 4 to select from default tables 1-4 at the back of this manual, or press “0” if you are not selecting a default table.

!If a default table is loaded, any data that has already been programmed into the system will be changed according to the default table selected!

96 resets all subscriber account numbers and CSID in preparation for an initial download.

Exiting Program Mode

98 inhibits re-entry into the Expert or Voice Prompt Programming modes using the Installer Code.

99 allows re-entry into the Expert Program mode using Installer Code (4112) + 800 or into the Voice Prompt Programming mode using Installer Code (4112) + 888.

Note: After exiting program mode (or upon power-up), the system takes up to a minute to reset. To bypass the reset delay, press [#] + [0].

–14–

Image 14
Contents Ademco Lynxr Series Security Systems Recommendations for Smoke and Heat Detectors Recommendations For Proper Intrusion ProtectionTable of Contents Hour backup System FeaturesHardwire zone Two-way voice communication Speaker phone operationMounting the Control Desktop MountingWiring Connections Wiring ConnectionsWiring Overview Full Line Seizure Connections This System 75 to 150 feet AC Power and Backup BatteryAC Power and Rechargeable Backup Battery 150 to 300 feetHours minimum Approximately 1-hour before battery depletion Hours minimum At least 1-hour before battery depletionHouse Identification Installing Wireless ZonesGeneral Information Transmitter SupervisionEnter Installer code 4112 + # + Transmitter Battery LifeUsing the Transmitter Sniffer Mode Go/No Go Test ModeSetting DIP Switches on the 5800RL and 5827 Transmitters Mechanics of Programming Loading Factory DefaultsExiting Program Mode General Programming InformationZone Not Used Type Entry/Exit Burglary #1 Zone Response Type DefinitionsType Type 02 Entry/Exit Burglary #25806/5807/5808 Defaults where applicable are Indicated in Text Data Field DescriptionsDialer Programming Fields 43Report Format for Primary/Secondary Follow Me Reminder Phone NumberPhone System Select Split/Dual ReportingSystem Status and Restore Report Codes Programming 59 76 Restore Report Codes System Status Report CodesRestore Report Codes Download Information 94 Device Programming Menu Mode Enabling the Wireless DialerEnhanced Zone Programming Mode Zone Lists for Menu ModeEnabling the 5842 Wireless Dialer Wireless Dialer SetupEnable back-up reporting Enable the wireless dialerEnable trouble reports Response to phone line tamperEnhanced Zone Programming Mode Report code Zone numberZone type Input typeConfirmation Enroll modeDelete zone parameters Descriptor Serial numberVoice descriptor Start by Event Device Programming Menu ModeProgramming Options Defined Start by Zone Type or System OperationStop Programming Powerline Carrier DevicesUpon Restore of a Zone List Upon a Zone Type or System OperationDevice number Powerline Carrier DeviceProgramming Device actionZone List Menu Mode Enter the 2-digit zone number Enhanced Sequential Mode00 = exit Sequential mode IA LC = copy the previous serial number entry from the bufferDelete serial number Assign Zone Voice Descriptors Assign zone voice descriptorsAssign Zone Voice Descriptor Voice Vocabulary IndexCustom descriptor number Record Custom Voice DescriptorsAssign custom voice descriptors Voice Prompt Programming Voice Prompt Programming Keypad FunctionsPatio Second Central Station Account NumberFront Basement Back Sliding ToenrollPendant Type To Enter Expert Programming Mode TemplateEquipment required to download to a system at the premises Remote Programming/Control DownloadingRemote Programming Information Remote Programming Advisory Notes Panic Keys System OperationSecurity Codes Message Center Volume ControlKeypad Functions Other FunctionsSpeaker Phone Operation LYNXR-EN Only Remote Phone Control FeatureRemote Phone Control Feature Activation Alarm Audio Verification Two-Way Voice FeatureOperator Commands Exit Error Alarm Displays Follow Me System Announcement FeaturePowerline Carrier Devices e.g. X-10 devices If programmedOther Displays Fault and Battery DisplaysTrouble Conditions Armed System Test Testing the SystemTest Mode System Communication Communication OverviewContact ID Event Codes Report +1/4+1 Standard +1/4+1 ExpandedTroubleshooting Guide S T E M i n c l u d i n g W i r e l e s sN T R O L O K E D E T E C T O RPLEASE, before you call Technical Support, be sure you Read the InstructionsRegulatory Agency Statements UL Notice This is a Grade a residential systemElectrical SpecificationsLYNXR-Series Security Controls CommunicationLYNXR/LYNXR24 Programming Default Tables LYNXR-EN Programming Default Tables Zone ASSIGNMENT/ALARM Report Codes for Table Event Start StopDevice Number System OperationIndex 20, 61Exit Delay Serial Number Page Limitations of this Alarm System Limited Warranty Police With System‡K5963V3oŠ

LYNXR Series, LYNXR-EN specifications

The Honeywell LYNXR Series, particularly the LYNXR-EN model, represents a pinnacle of advanced security technology designed for residential and small business applications. This all-in-one wireless security system is lauded for its innovative features, ease of use, and powerful performance, making it a top choice among users seeking enhanced security solutions.

One of the standout features of the LYNXR-EN is its user-friendly touchscreen interface. The large, intuitive display allows for straightforward navigation, enabling users to arm or disarm the system, check status, and receive alerts with just a few taps. This ease of use is complemented by programmable quick access keys, which allow users to personalize their experience according to their security requirements.

Additionally, the LYNXR-EN is designed with flexibility in mind. It supports a wide range of wireless sensors and devices, facilitating comprehensive coverage for homes or small businesses. Users can integrate door and window contacts, motion detectors, glass break sensors, and more, ensuring that every entry point is monitored. The system can accommodate up to 48 wireless zones, allowing for extensive security applications without the clutter of wires.

Technologically, the LYNXR-EN leverages advanced RF technology, enhancing the reliability of communication between the panel and sensors. This feature minimizes the risk of interference and ensures consistent performance even in challenging environments. Along with this robust connectivity, the system offers dual-path communication capabilities, enabling both IP and cellular reporting. This redundancy ensures that alerts are promptly sent to the monitoring center and mobile devices, providing peace of mind to users.

Moreover, the LYNXR-EN can be easily integrated with smart home technology. It is compatible with various smart devices, allowing users to control lighting, thermostats, and other home automation features from a single platform. This integration not only enhances convenience but also optimizes energy efficiency.

The LYNXR-EN also includes a built-in battery backup, ensuring that the system remains operational during power outages. This is a crucial feature for maintaining security when it is needed most. Additionally, users can set up customizable alerts and notifications, allowing them to stay informed of any unusual activity in real-time.

In summary, the Honeywell LYNXR Series, especially the LYNXR-EN model, combines advanced technology with user-friendly design to deliver a versatile and robust security solution. Its wireless capabilities, comprehensive sensor support, smart home integration, and reliable communication make it a prominent choice in the ever-evolving realm of security systems.