Honeywell LYNXR-EN Remote Programming/Control Downloading, Remote Programming Information

Page 45

Remote Programming/Control (Downloading)

General Information

The control panel can be remotely programmed from an IBM-compatible Personal Computer (PC), a HAYES Modem, and ADEMCO’s Compass Downloader for Windows (as specified below).

UL

Downloading may only be performed if a technician is at the site.

 

 

Multiple security levels protect remote programming against compromise by attempts to defeat the system.

1.Security Code Handshake: An 8-digit download ID code must be matched between the Control and downloader.

2.Site-Initiated Remote Programming: The installer or subscriber initiates the call from the subscriber premises (by entering Installer Code + # + 1) while disarmed. All parameters can then be downloaded via the phone lines using a personal computer.

3.Station-Initiated Remote Programming: The operator calls the site from your office to initiate the download call. The Control hangs up and then calls back the PC via the preprogrammed telephone number. The unit can then be uploaded, downloaded, or controlled from your office.

4.Telco Handoff: The installer or subscriber performs a download session on the call initiated from the site or from local laptop computer (by entering Installer or Master Code + # + 1 at the control panel).

5.Data Encryption: Data passed between the PC and the Control is encrypted for security so that it is very difficult for a foreign device tapped into the phone line to take over communication and substitute system-compromising information.

Equipment required to download to a system at the premises

An IBM PC compatible computer and appropriate interconnecting cables.

Either a HAYES brand SMARTMODEM 1200 (Level 1.2 or higher external or Level 1.1 or higher [with 4 position DIP switch] internal style), a HAYES brand Optima 336 external, a HAYES brand Optima 24 Plus FAX96, or an Ademco CIA Modem.

Compass Downloader for Windows (at revision level supporting LYNXR, LYNXR24 or LYNXR-EN).

Initial Download: Enter Installer Code + # + 5. This sets field 95 to 4 rings, and system to “no call-back” option. The download computer can then call the subscriber, make connection, and download all programming data.

Flexible Callback: If enabled in field 93, the download operator can temporarily change the last 1, 2, or 3 digits (depending on selection) of the call back number. This allows the control to call back a computer other than the one programmed, which may be helpful at times of high computer traffic. See field 93 for a full description.

Remote Programming Information

LYNX must be connected to the telephone line if using Remote Programming.

The downloading system can perform many functions when in communication with the Control. Besides uploading and downloading, the status of the system can be observed and various commands can be initiated, as follows:

Arm the system in the away mode; disarm the system.

Bypass a zone.

Force the system to accept a new program download.

Shut down communication (dialer) functions (for nonpayment of monitoring fees in an owned system).

Shut down all security system functions (for nonpayment for a leased system).

Inhibit local keypad programming (prevents account takeover).

–45–

Image 45
Contents Ademco Lynxr Series Security Systems Recommendations For Proper Intrusion Protection Recommendations for Smoke and Heat DetectorsTable of Contents Hardwire zone System FeaturesHour backup Two-way voice communication Speaker phone operationDesktop Mounting Mounting the ControlWiring Connections Wiring OverviewWiring Connections Full Line Seizure Connections This System AC Power and Rechargeable Backup Battery AC Power and Backup Battery75 to 150 feet 150 to 300 feetHours minimum At least 1-hour before battery depletion Hours minimum Approximately 1-hour before battery depletionGeneral Information Installing Wireless ZonesHouse Identification Transmitter SupervisionUsing the Transmitter Sniffer Mode Transmitter Battery LifeEnter Installer code 4112 + # + Go/No Go Test ModeSetting DIP Switches on the 5800RL and 5827 Transmitters Exiting Program Mode Loading Factory DefaultsMechanics of Programming General Programming InformationType Zone Response Type DefinitionsZone Not Used Type Entry/Exit Burglary #1 Type 02 Entry/Exit Burglary #25806/5807/5808 Data Field Descriptions Defaults where applicable are Indicated in TextFields 43 Dialer ProgrammingPhone System Select Follow Me Reminder Phone NumberReport Format for Primary/Secondary Split/Dual ReportingSystem Status and Restore Report Codes Programming 59 76 System Status Report Codes Restore Report CodesRestore Report Codes Download Information 94 Enhanced Zone Programming Mode Enabling the Wireless DialerDevice Programming Menu Mode Zone Lists for Menu ModeWireless Dialer Setup Enabling the 5842 Wireless DialerEnable trouble reports Enable the wireless dialerEnable back-up reporting Response to phone line tamperEnhanced Zone Programming Mode Zone type Zone numberReport code Input typeEnroll mode Delete zone parametersConfirmation Serial number Voice descriptorDescriptor Programming Options Defined Device Programming Menu ModeStart by Event Start by Zone Type or System OperationUpon Restore of a Zone List Programming Powerline Carrier DevicesStop Upon a Zone Type or System OperationProgramming Powerline Carrier DeviceDevice number Device actionZone List Menu Mode Enhanced Sequential Mode 00 = exit Sequential modeEnter the 2-digit zone number = copy the previous serial number entry from the buffer IA LCDelete serial number Assign zone voice descriptors Assign Zone Voice DescriptorsVoice Vocabulary Index Assign Zone Voice DescriptorRecord Custom Voice Descriptors Assign custom voice descriptorsCustom descriptor number Voice Prompt Programming Keypad Functions Voice Prompt ProgrammingFront Basement Back Sliding Second Central Station Account NumberPatio ToenrollPendant Type Template To Enter Expert Programming ModeRemote Programming/Control Downloading Remote Programming InformationEquipment required to download to a system at the premises Remote Programming Advisory Notes System Operation Security CodesPanic Keys Keypad Functions Volume ControlMessage Center Other FunctionsRemote Phone Control Feature Remote Phone Control FeatureSpeaker Phone Operation LYNXR-EN Only Alarm Audio Verification Two-Way Voice Feature Operator CommandsActivation Powerline Carrier Devices e.g. X-10 devices Follow Me System Announcement FeatureExit Error Alarm Displays If programmedFault and Battery Displays Trouble ConditionsOther Displays Testing the System Test ModeArmed System Test Communication Overview System CommunicationReport +1/4+1 Standard +1/4+1 Expanded Contact ID Event CodesS T E M i n c l u d i n g W i r e l e s s Troubleshooting GuideO K E D E T E C T O R N T R O LRead the Instructions PLEASE, before you call Technical Support, be sure youUL Notice This is a Grade a residential system Regulatory Agency StatementsLYNXR-Series Security Controls SpecificationsElectrical CommunicationLYNXR/LYNXR24 Programming Default Tables LYNXR-EN Programming Default Tables Zone ASSIGNMENT/ALARM Report Codes for Table Device Number Start StopEvent System Operation20, 61 IndexExit Delay Serial Number Page Limitations of this Alarm System Limited Warranty System Police With‡K5963V3oŠ

LYNXR Series, LYNXR-EN specifications

The Honeywell LYNXR Series, particularly the LYNXR-EN model, represents a pinnacle of advanced security technology designed for residential and small business applications. This all-in-one wireless security system is lauded for its innovative features, ease of use, and powerful performance, making it a top choice among users seeking enhanced security solutions.

One of the standout features of the LYNXR-EN is its user-friendly touchscreen interface. The large, intuitive display allows for straightforward navigation, enabling users to arm or disarm the system, check status, and receive alerts with just a few taps. This ease of use is complemented by programmable quick access keys, which allow users to personalize their experience according to their security requirements.

Additionally, the LYNXR-EN is designed with flexibility in mind. It supports a wide range of wireless sensors and devices, facilitating comprehensive coverage for homes or small businesses. Users can integrate door and window contacts, motion detectors, glass break sensors, and more, ensuring that every entry point is monitored. The system can accommodate up to 48 wireless zones, allowing for extensive security applications without the clutter of wires.

Technologically, the LYNXR-EN leverages advanced RF technology, enhancing the reliability of communication between the panel and sensors. This feature minimizes the risk of interference and ensures consistent performance even in challenging environments. Along with this robust connectivity, the system offers dual-path communication capabilities, enabling both IP and cellular reporting. This redundancy ensures that alerts are promptly sent to the monitoring center and mobile devices, providing peace of mind to users.

Moreover, the LYNXR-EN can be easily integrated with smart home technology. It is compatible with various smart devices, allowing users to control lighting, thermostats, and other home automation features from a single platform. This integration not only enhances convenience but also optimizes energy efficiency.

The LYNXR-EN also includes a built-in battery backup, ensuring that the system remains operational during power outages. This is a crucial feature for maintaining security when it is needed most. Additionally, users can set up customizable alerts and notifications, allowing them to stay informed of any unusual activity in real-time.

In summary, the Honeywell LYNXR Series, especially the LYNXR-EN model, combines advanced technology with user-friendly design to deliver a versatile and robust security solution. Its wireless capabilities, comprehensive sensor support, smart home integration, and reliable communication make it a prominent choice in the ever-evolving realm of security systems.