Honeywell LYNXR-EN, LYNXR Series setup guide Enhanced Zone Programming Mode

Page 27

56 Enhanced Zone Programming Mode

This is an interactive menu mode that is used to program zone numbers, zone types, alarm and report codes, and to identify the type of loop input device. This mode can also be used for entering 5800 Series transmitter serial numbers.

Note: There are two methods for entering transmitter serial numbers. The first method is by using 56 Enhanced Zone Programming mode (described below). The second method is by using 83 Enhanced Sequential Mode. Note that the 83 Enhanced Sequential Mode requires that all zone information first be entered using 56 Enhanced Zone Programming mode.

You must refer to these instructions or to the Program Form while programming the system because the keypad display does not show prompt titles. Instead, prompts are indicated by a number/letter combination. The prompts for 56 are as follows:

A 01

Zone Number -----------------------

for entering the zone number

 

 

 

 

 

 

b

Zone Type----------------------------

for entering zone type

 

 

 

 

 

 

C

Report Code -------------------------

for entering the zone’s report code

 

 

 

 

 

 

d

Input Type---------------------------

for entering the transmitter’s input type

 

 

 

 

 

 

E

Loop Number -----------------------

for entering the transmitter loop number

 

 

 

F

Delete Serial Number? ----------

for deleting existing serial number

 

 

 

1A

Enroll Mode?------------------------

selects serial number enroll mode

 

 

 

1b

Serial Number ---------------------

for entering transmitter’s serial number

 

 

 

1C

Voice Descriptor? ------------------

selects voice descriptor mode

 

 

 

1d

Descriptor 1 -------------------------

for entering first descriptor word

 

 

 

1E

Descriptor 2 -------------------------

for entering second descriptor word

 

 

 

1F

Descriptor 3 -------------------------

for entering third descriptor word

–27–

Image 27
Contents Ademco Lynxr Series Security Systems Recommendations For Proper Intrusion Protection Recommendations for Smoke and Heat DetectorsTable of Contents Two-way voice communication Speaker phone operation System FeaturesHardwire zone Hour backupDesktop Mounting Mounting the ControlWiring Connections Wiring OverviewWiring Connections Full Line Seizure Connections This System 150 to 300 feet AC Power and Backup BatteryAC Power and Rechargeable Backup Battery 75 to 150 feetHours minimum At least 1-hour before battery depletion Hours minimum Approximately 1-hour before battery depletionTransmitter Supervision Installing Wireless ZonesGeneral Information House IdentificationGo/No Go Test Mode Transmitter Battery LifeUsing the Transmitter Sniffer Mode Enter Installer code 4112 + # +Setting DIP Switches on the 5800RL and 5827 Transmitters General Programming Information Loading Factory DefaultsExiting Program Mode Mechanics of ProgrammingType 02 Entry/Exit Burglary #2 Zone Response Type DefinitionsType Zone Not Used Type Entry/Exit Burglary #15806/5807/5808 Data Field Descriptions Defaults where applicable are Indicated in TextFields 43 Dialer ProgrammingSplit/Dual Reporting Follow Me Reminder Phone NumberPhone System Select Report Format for Primary/SecondarySystem Status and Restore Report Codes Programming 59 76 System Status Report Codes Restore Report CodesRestore Report Codes Download Information 94 Zone Lists for Menu Mode Enabling the Wireless DialerEnhanced Zone Programming Mode Device Programming Menu ModeWireless Dialer Setup Enabling the 5842 Wireless DialerResponse to phone line tamper Enable the wireless dialerEnable trouble reports Enable back-up reportingEnhanced Zone Programming Mode Input type Zone numberZone type Report codeEnroll mode Delete zone parametersConfirmation Serial number Voice descriptorDescriptor Start by Zone Type or System Operation Device Programming Menu ModeProgramming Options Defined Start by EventUpon a Zone Type or System Operation Programming Powerline Carrier DevicesUpon Restore of a Zone List StopDevice action Powerline Carrier DeviceProgramming Device numberZone List Menu Mode Enhanced Sequential Mode 00 = exit Sequential modeEnter the 2-digit zone number = copy the previous serial number entry from the buffer IA LCDelete serial number Assign zone voice descriptors Assign Zone Voice DescriptorsVoice Vocabulary Index Assign Zone Voice DescriptorRecord Custom Voice Descriptors Assign custom voice descriptorsCustom descriptor number Voice Prompt Programming Keypad Functions Voice Prompt ProgrammingToenroll Second Central Station Account NumberFront Basement Back Sliding PatioPendant Type Template To Enter Expert Programming ModeRemote Programming/Control Downloading Remote Programming InformationEquipment required to download to a system at the premises Remote Programming Advisory Notes System Operation Security CodesPanic Keys Other Functions Volume ControlKeypad Functions Message CenterRemote Phone Control Feature Remote Phone Control FeatureSpeaker Phone Operation LYNXR-EN Only Alarm Audio Verification Two-Way Voice Feature Operator CommandsActivation If programmed Follow Me System Announcement FeaturePowerline Carrier Devices e.g. X-10 devices Exit Error Alarm DisplaysFault and Battery Displays Trouble ConditionsOther Displays Testing the System Test ModeArmed System Test Communication Overview System CommunicationReport +1/4+1 Standard +1/4+1 Expanded Contact ID Event CodesS T E M i n c l u d i n g W i r e l e s s Troubleshooting GuideO K E D E T E C T O R N T R O LRead the Instructions PLEASE, before you call Technical Support, be sure youUL Notice This is a Grade a residential system Regulatory Agency StatementsCommunication SpecificationsLYNXR-Series Security Controls ElectricalLYNXR/LYNXR24 Programming Default Tables LYNXR-EN Programming Default Tables Zone ASSIGNMENT/ALARM Report Codes for Table System Operation Start StopDevice Number Event20, 61 IndexExit Delay Serial Number Page Limitations of this Alarm System Limited Warranty System Police With‡K5963V3oŠ

LYNXR Series, LYNXR-EN specifications

The Honeywell LYNXR Series, particularly the LYNXR-EN model, represents a pinnacle of advanced security technology designed for residential and small business applications. This all-in-one wireless security system is lauded for its innovative features, ease of use, and powerful performance, making it a top choice among users seeking enhanced security solutions.

One of the standout features of the LYNXR-EN is its user-friendly touchscreen interface. The large, intuitive display allows for straightforward navigation, enabling users to arm or disarm the system, check status, and receive alerts with just a few taps. This ease of use is complemented by programmable quick access keys, which allow users to personalize their experience according to their security requirements.

Additionally, the LYNXR-EN is designed with flexibility in mind. It supports a wide range of wireless sensors and devices, facilitating comprehensive coverage for homes or small businesses. Users can integrate door and window contacts, motion detectors, glass break sensors, and more, ensuring that every entry point is monitored. The system can accommodate up to 48 wireless zones, allowing for extensive security applications without the clutter of wires.

Technologically, the LYNXR-EN leverages advanced RF technology, enhancing the reliability of communication between the panel and sensors. This feature minimizes the risk of interference and ensures consistent performance even in challenging environments. Along with this robust connectivity, the system offers dual-path communication capabilities, enabling both IP and cellular reporting. This redundancy ensures that alerts are promptly sent to the monitoring center and mobile devices, providing peace of mind to users.

Moreover, the LYNXR-EN can be easily integrated with smart home technology. It is compatible with various smart devices, allowing users to control lighting, thermostats, and other home automation features from a single platform. This integration not only enhances convenience but also optimizes energy efficiency.

The LYNXR-EN also includes a built-in battery backup, ensuring that the system remains operational during power outages. This is a crucial feature for maintaining security when it is needed most. Additionally, users can set up customizable alerts and notifications, allowing them to stay informed of any unusual activity in real-time.

In summary, the Honeywell LYNXR Series, especially the LYNXR-EN model, combines advanced technology with user-friendly design to deliver a versatile and robust security solution. Its wireless capabilities, comprehensive sensor support, smart home integration, and reliable communication make it a prominent choice in the ever-evolving realm of security systems.